Comparison of two cohorts of women who expulsed either a copper-intrauterine device or a levonorgestrel-releasing intrauterine system

被引:12
|
作者
Simonatto, Paula
Bahamondes, Maria Valeria
Fernandes, Arlete
Silveira, Carolina
Bahamondes, Luis
机构
[1] Univ Estadual Campinas, Human Reprod Unit, Dept Obstet & Gynaecol, Sch Med Sci,UNICAMP, Campinas, SP, Brazil
[2] Univ Estadual Campinas, Natl Inst Hormones & Womens Hlth, UNICAMP, Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
copper IUD; expulsion; Intrauterine device; levonorgestrel-releasing intrauterine system; T-SHAPED IUDS; NULLIPAROUS WOMEN; RISK-FACTORS; PERFORMANCE; CONTRACEPTION; FAILURE; TRIAL;
D O I
10.1111/jog.12939
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
AimTo assess if there is a difference in the characteristics of the women who expelled a copper-intrauterine device (TCu-IUD) or the levonorgestrel-releasing intrauterine system (LNG-IUS) and the frequency of expulsions over different periods of observation. MethodsWe retrospectively analyzed 19697 medical charts of women consulting between January 1980 and December 2013 who requested a TCu-IUD or a LNG-IUS. ResultsThe medical records of 17644 Cu-IUD and 2053 LNG-IUS users returning to the clinic for a follow-up visit after insertion of an IUC were reviewed. Of these, 1532 Cu-IUD and 254 LNG-IUS parous users were found to have expelled the IUC for a first time. The mean age at insertion ( standard deviation) was 26.3 +/- 6.6 years (range 16-49) for Cu-IUD users and 31.7 +/- 7.6 years (range 18-48) for LNG-IUS users (P < 0.001). A total of 263 (13.4%) and 12 (4.3%) of the Cu-IUD and the LNG-IUS users were 19 years old, and 49.1% and 54.1% of the expulsions among the Cu-IUD and LNG-IUS users, respectively, were reported in the first six months after placement. A regression model showed that the variables significantly associated with an expulsion of either a Cu-IUD or LNG-IUS were age < 25 years, less than two deliveries and using a Cu-IUD. ConclusionOur findings showed that the characteristics associated with IUC expulsion were age under 25 years, having had less than two deliveries and being users of Cu-IUD.
引用
收藏
页码:554 / 559
页数:6
相关论文
共 50 条
  • [1] COMPARISON OF PAIN LEVEL DURING AND AFTER INTRAUTERINE DEVICE INSERTION: LEVONORGESTREL-RELEASING INTRAUTERINE SYSTEM VERSUS THE COPPER T INTRAUTERINE DEVICE
    Cirstoiu, Monica
    Munteanu, Octavian
    Antoniac, Iulian
    Cirstoiu, Catalin
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2016, 15 (05): : 965 - 972
  • [2] Analysis of the levonorgestrel-releasing intrauterine system in women with endometriosis
    Shen Lan
    Liu Ling
    Zhao Jianhong
    Jiang Xijing
    Wang Lihui
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2013, 41 (03) : 548 - 558
  • [3] Use of the levonorgestrel-releasing intrauterine system: an Austrian perspective
    Concin, Hans
    Boesch, Hubert
    Hintermueller, Peter
    Hohlweg, Thomas
    Mursch-Edlmayr, Gerhard
    Pinnisch, Bettina
    Schmidl-Amann, Sigrid
    Schulz-Greinwald, Gunda
    Unterlerchner, Dagmar
    Wagner, Teresa
    Mattle, Verena
    Wildt, Ludwig
    Fiala, Christian
    CURRENT OPINION IN OBSTETRICS & GYNECOLOGY, 2009, 21 : S1 - S9
  • [4] Effects of levonorgestrel-releasing intrauterine system and T380A intrauterine copper device on dysmenorrhea and days of bleeding in women with and without adenomyosis
    Kelekci, Sefa
    Kelekci, Kiymet Handan
    Yilmaz, Bulent
    CONTRACEPTION, 2012, 86 (05) : 458 - 463
  • [5] Uterine perforation in women using a levonorgestrel-releasing intrauterine system
    Van Houdenhoven, K
    van Kaam, K
    van Grootheest, AC
    Salemans, THB
    Dunselman, GAJ
    CONTRACEPTION, 2006, 73 (03) : 257 - 260
  • [6] Levonorgestrel-releasing Intrauterine Device is an Efficacious Contraceptive for Women with Leiomyoma
    Xie, Z.-W.
    Zhang, Y.-N.
    Wan, S.
    Xu, W.-Z.
    Chen, J.
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2012, 40 (05) : 1966 - 1972
  • [7] Levonorgestrel-Releasing Intrauterine System as a Contraceptive Method in Nulliparous Women: A Systematic Review
    Zgliczynska, Magdalena
    Kocaj, Karol
    Szymusik, Iwona
    Dutsch-Wicherek, Magdalena Maria
    Ciebiera, Michal
    Kosinska-Kaczynska, Katarzyna
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (07) : 1 - 14
  • [8] Pain at insertion of the levonorgestrel-releasing intrauterine system in nulligravida and parous women with and without cesarean section
    Gouvea Santos, Ana Raquel
    Valeria Bahamondes, M.
    Margarete Hidalgo, M.
    Atti, Ana
    Bahamondes, Luis
    Monteiro, Ilza
    CONTRACEPTION, 2013, 88 (01) : 164 - 168
  • [9] A survey of young women's perceptions of the influence of the Levonorgestrel-Intrauterine System or copper-intrauterine device on sexual desire
    Malmborg, Agota
    Brynhildsen, Jan
    Hammar, Mats
    SEXUAL & REPRODUCTIVE HEALTHCARE, 2019, 21 : 75 - 80
  • [10] Recent developments in the clinical use of the levonorgestrel-releasing intrauterine system
    Gemzell-Danielsson, Kristina
    Inki, Pirjo
    Heikinheimo, Oskari
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2011, 90 (11) : 1177 - 1188