Experimental investigation of axial fan erosion and performance degradation

被引:33
作者
Ghenaiet, A
Tan, SC
Elder, RL
机构
[1] Polytech Sch, Thermal Power Lab, Algiers, Algeria
[2] Wichita State Univ, Kansas City, KS USA
[3] PCA Engn, Bedford, England
关键词
axial fan; sand particles; erosion; performance degradation; laser transit anemometer;
D O I
10.1243/0957650041761900
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental investigation was conducted to study the effects of sand ingestion on an axial fan with an upstream guide vane (contra-whirl). The experimental work was divided into two types of testing. Firstly, local injection tests were carried out to generate qualitative erosion patterns in order to validate a trajectory code. Secondly, global sand injection tests were carried out in order to assess the geometry deterioration and the subsequent degradation in the axial fan aerodynamic characteristics. Two types of particle were used; a narrow size bandwidth sand (150-300 mum) and MIL-E5007E sand (0-1000 mum). In all sand injection tests the fan operated near design point at a constant speed of rotation.
引用
收藏
页码:437 / 450
页数:14
相关论文
共 17 条
[1]  
AHMED N, 1991, P INSTN MECH ENG G, V205
[2]  
Balan C., 1984, AIAA SAE ASME 20 JOI, P1280, DOI DOI 10.2514/6.1984-1208
[3]  
*BRIT STAND, BS4999 BRIT STAND
[4]  
*BRIT STAND, 1997, BS848 BRIT STAND
[5]  
*BRIT STAND, 1983, BS104221 BRIT STAND
[6]  
Eckardt D., 1986, ADV EXPT TECHNIQUES
[7]  
Edwards R.V, 1994, 83 S PROP EN PAN ER
[8]  
Ghenaiet A., 2001, THESIS CRANFIELD U
[9]  
GILL ME, 1981, DESCRIPTION PROGRAMM
[10]  
Harris P.K., 1996, THESIS CRANFIELD U