A method for the detection of nitroaromatic and nitramine explosives from a PTFE wipe has been developed using thermal desorption and gas chromatography with electron-capture detection (TD-GC-ECD). For method development a standard mixture containing eight nitroaromatic and two nitramine (HMX and RDX) explosive compounds was spiked onto a PTFE wipe. Explosives were desorbed from the wipe in a commercial thermal desorption system and trapped onto a cooled injection system, which was incorporated into the injection port of the GC. A dual column, dual ECD configuration was adopted to enable simultaneous confirmation analysis of the explosives desorbed. For the desorption of 50ng of each explosive, desorption efficiencies ranged between 80.0 and 117%, for both columns. Linearity over the range 2.5-50 ng was demonstrated for each explosive on both columns with r(2) values ranging from 0.979 to 0.991 and limits of detection less than 4 ng. Desorption of HMX from a PTFE wipe has also been demonstrated for the first time, albeit at relatively high loadings (100 ng). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 131
页数:7
相关论文
共 50 条
  • [1] Thermal desorption of HMX from a PTFE wipe by gas chromatography with electron-capture detection using a dual column-dual detector configuration.
    Waddell, R
    Dale, DE
    Monagle, M
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U129 - U129
  • [2] Determination of nitroaromatic, nitramine, and nitrate ester explosives in soil by gas chromatography and an electron capture detector
    Walsh, ME
    TALANTA, 2001, 54 (03) : 427 - 438
  • [3] Determination of nitroaromatic, nitramine, and nitrate ester explosives in water using solid-phase extraction and gas chromatography electron capture detection: Comparison with high-performance liquid chromatography
    Walsh, ME
    Ranney, T
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1998, 36 (08) : 406 - 416
  • [4] Determination of methyltetrahydrophthalic anhydride in air using gas chromatography with electron-capture detection
    Johyama, Y
    Yokota, K
    Fujiki, Y
    Takeshita, T
    Morimoto, K
    INDUSTRIAL HEALTH, 1999, 37 (04) : 364 - 368
  • [5] DETERMINATION OF ACRYLAMIDE IN WATER BY USING ELECTRON-CAPTURE GAS CHROMATOGRAPHY
    CROLL, BT
    SIMKINS, GM
    ANALYST, 1972, 97 (1153) : 281 - &
  • [6] DETERMINATION OF CYCLOHEXYLAMINE BY ELECTRON-CAPTURE GAS CHROMATOGRAPHY
    WESTON, RE
    WHEALS, BB
    ANALYST, 1970, 95 (1132) : 680 - &
  • [7] DIRECT DETERMINATION OF CARBARYL BY GAS-LIQUID-CHROMATOGRAPHY USING ELECTRON-CAPTURE DETECTION
    LEWIS, DL
    PARIS, DF
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1974, 22 (01) : 148 - 149
  • [8] Determination of paroxetine levels in human plasma using gas chromatography with electron-capture detection
    Lai, CT
    Gordon, ES
    Kennedy, SH
    Bateson, AN
    Coutts, RT
    Baker, GB
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2000, 749 (02): : 275 - 279
  • [9] Determination of acetaldehyde in biological samples by gas chromatography with electron-capture detection
    Ohata, H
    Otsuka, M
    Ohmori, S
    JOURNAL OF CHROMATOGRAPHY B, 1997, 693 (02): : 297 - 305
  • [10] DETERMINATION OF LORMETAZEPAM IN PLASMA BY GAS-CHROMATOGRAPHY AND ELECTRON-CAPTURE DETECTION
    ZECCA, L
    FERRARIO, P
    FRASCHINI, F
    ZAMBOTTI, F
    ZONTA, N
    PIROLA, R
    JOURNAL OF CHROMATOGRAPHY, 1986, 377 : 368 - 372