Characterization of Small Incidental Indeterminate Hypoattenuating Hepatic Lesions: Added Value of Single-Phase Contrast-Enhanced Dual-Energy CT Material Attenuation Analysis

被引:31
作者
Patel, Bhavik N. [1 ]
Rosenberg, Michael [2 ]
Vernuccio, Federica [2 ]
Ramirez-Giraldo, Juan Carlos [3 ]
Nelson, Rendon [2 ]
Farjat, Alfredo [4 ]
Marin, Daniele [2 ]
机构
[1] Stanford Univ, Dept Radiol, Sch Med, Stanford, CA 94305 USA
[2] Duke Univ, Div Abdominal Imaging, Dept Radiol, Med Ctr, Box 3808 Erwin Rd, Durham, NC 27710 USA
[3] Duke Univ, Med Ctr, Carl E Ravin Adv Imaging Labs, RAI Labs, Durham, NC USA
[4] Duke Univ, Dept Biostat & Bioinformat, Med Ctr, Durham, NC USA
关键词
dual-energy CT; enhancement; incidental; iodine; liver lesions; FOCAL LIVER-LESIONS; EMERGENCY-DEPARTMENT; ABDOMINAL CT; WHITE PAPER; PREVALENCE; MANAGEMENT; PRINCIPLES;
D O I
10.2214/AJR.17.19170
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of this study is to determine whether single-phase contrast-enhanced dual-energy CT (DECT) material attenuation analysis improves the characterization of small (< 2.0 cm) incidental indeterminate hypoattenuating hepatic lesions, compared with conventional single-energy CT evaluation. MATERIALS AND METHODS. This retrospective study involved 55 patients (24 men and 31 women; mean [+/- SD] age, 63.9 +/- 15.3 years) with 77 incidental hypoattenuating hepatic lesions (59 benign and 18 malignant lesions) measuring 0.5-2.0 cm who underwent single-phase contrast-enhanced DECT of the abdomen for pain. For each lesion, attenuation measurements were obtained using blended 120-kVp-equivalent images and contrast map images. DECT material attenuation images were used for iodine quantification. Optimal lesion attenuation and iodine concentration threshold values that best distinguished benign lesions from malignant lesions were generated using smooth bootstrapping. The diagnostic accuracy of the optimized thresholds was compared using the Wilcox rank sum test. RESULTS. The optimal mean (+/- standard error) attenuation threshold values that best differentiated benign and malignant lesions were 50.2 +/- 5.2 HU and 11.5 +/- 2.0 HU when blended 120-kVp and contrast map images, respectively, were used. The iodine concentration (expressed as milligrams of iodine per milliliter) differed significantly (p < 0.0001) between benign lesions (0.6 +/- 0.4 mg I/mL) and malignant lesions (1.7 +/- 0.4 mg I/mL). The optimal iodine concentration that best distinguished between benign and malignant lesions was 1.2 +/- 0.1 mg I/mL. The sensitivity, specificity, and AUC value were highest for iodine concentration (0.94, 0.93, and 0.97, respectively), compared with blended images (0.89, 0.70, and 0.81, respectively) and contrast map images (0.94, 0.64, 0.77, respectively). CONCLUSION. Iodine quantification performed using single-phase contrast-enhanced DECT material attenuation images improves the characterization of small (< 2 cm) incidental indeterminate hypoattenuating hepatic lesions, compared with conventional attenuation measurements.
引用
收藏
页码:571 / 579
页数:9
相关论文
共 34 条
[1]   Oncologic Applications of Dual-Energy CT in the Abdomen [J].
Agrawal, Mukta D. ;
Pinho, Daniella F. ;
Kulkarni, Naveen M. ;
Hahn, Peter F. ;
Guimaraes, Alexander R. ;
Sahani, Dushyant V. .
RADIOGRAPHICS, 2014, 34 (03) :589-612
[2]  
American Association of Physicists in Medicine, SIZ SPEC DOS EST SSD
[3]  
American College of Radiology (ACR), ACR APPR CRIT AC NON
[4]   Managing Incidental Findings on Abdominal CT: White Paper of the ACR Incidental Findings Committee [J].
Berland, Lincoln L. ;
Silverman, Stuart G. ;
Gore, Richard M. ;
Mayo-Smith, William W. ;
Megibow, Alec J. ;
Yee, Judy ;
Brink, James A. ;
Baker, Mark E. ;
Federle, Michael P. ;
Foley, W. Dennis ;
Francis, Isaac R. ;
Herts, Brian R. ;
Israel, Gary M. ;
Krinsky, Glenn ;
Platt, Joel F. ;
Shuman, William P. ;
Taylor, Andrew J. .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2010, 7 (10) :754-773
[5]  
Blake MA, 2011, RADIOGRAPHICS, V31, P1047, DOI 10.1148/rg.314105159
[6]   Cystic Hepatic Lesions: A Review and an Algorithmic Approach [J].
Borhani, Amir A. ;
Wiant, Amanda ;
Heller, Matthew T. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (06) :1192-1204
[7]   STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies [J].
Bossuyt, Patrick M. ;
Reitsma, Johannes B. ;
Bruns, David E. ;
Gatsonis, Constantine A. ;
Glasziou, Paul P. ;
Irwig, Les ;
Lijmer, Jeroen G. ;
Moher, David ;
Rennie, Drummond ;
de Vet, Henrica C. W. ;
Kressel, Herbert Y. ;
Rifai, Nader ;
Golub, Robert M. ;
Altman, Douglas G. ;
Hooft, Lotty ;
Korevaar, Daniel A. ;
Cohen, Jeremie F. .
RADIOLOGY, 2015, 277 (03) :826-832
[8]   Dual-Energy CT: Oncologic Applications [J].
De Cecco, Carlo Nicola ;
Darnell, Anna ;
Rengo, Marco ;
Muscogiuri, Giuseppe ;
Bellini, Davide ;
Ayuso, Carmen ;
Laghi, Andrea .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :S98-S105
[9]   Fortuitously discovered liver lesions [J].
Dietrich, Christoph F. ;
Sharma, Malay ;
Gibson, Robert N. ;
Schreiber-Dietrich, Dagmar ;
Jenssen, Christian .
WORLD JOURNAL OF GASTROENTEROLOGY, 2013, 19 (21) :3173-3188
[10]   Management of Incidental Liver Lesions on CT: A White Paper of the ACR Incidental Findings Committee [J].
Gore, Richard M. ;
Pickhardt, Perry J. ;
Mortele, Koenraad J. ;
Fishman, Elliot K. ;
Horowitz, Jeanne M. ;
Fimmel, Claus J. ;
Talamonti, Mark S. ;
Berland, Lincoln L. ;
Pandharipande, Pari V. .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2017, 14 (11) :1429-1437