Poor practice and governance in Lebanese national diagnostic reference levels of adult head and body computed tomography: A nationwide study

被引:5
|
作者
Karout, Lina [1 ]
Khalife, Sarah [2 ]
Awad, Mohamad Fawzi [2 ]
Arnous, Ghida [2 ]
Roumie, Mohamad [3 ]
Rawashdeh, Mohammad Ahmmad [4 ]
Saade, Charbel [5 ]
机构
[1] Amer Univ Beirut, Radiol Dept, POBox 11-0236, Beirut 11072020, Lebanon
[2] Amer Univ Beirut, Fac Hlth Sci, Med Imaging Sci, POB 11-0236, Beirut 11072020, Lebanon
[3] Natl Council Sci Res, Lebanese Atom Energy Commiss, Airport Rd,POB 11-8281, Beirut 11072020, Lebanon
[4] Jordan Univ Sci & Technol Irbid, Dept Allied Med Sci, POB 3030, Irbid 22110, Jordan
[5] Univ Coll Cork, Fac Hlth Sci, Med Imaging Sci, Coll Rd, Cork T12 K8AF, Ireland
关键词
Radiation protection; Radiation dosage; Tomography; X-ray computed; Radiation exposure; DOSE MANAGEMENT; X-RAY; CT; ESTABLISHMENT; OPTIMIZATION; RADIOLOGY; EVALUATE; VALUES;
D O I
10.1016/j.radphyschem.2021.109888
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Lebanon has one of the highest number of computed tomography (CT) scanners per capita in the world which could likely be one of the causative factors of its high cancer incidence. In this study, we aimed to establish a national diagnostic reference level (NDRL) in adult CT examinations of the head and body in Lebanon. Dose Length Product (DLP) (n = 2730) were recorded in 91 hospitals/centers in Lebanon for head, chest, and abdomen-pelvis CT. Data was obtained from adult patients (>= 18 years) with a weight range of 75-80 kg, from January 2018 until December 2019. Then, the median, mean and 75th percentile of the DLP was calculated for each anatomical region. NDRL was reported as the 75th percentile. Then, the established NDRL was bench-marked with international countries as the USA, UK, and Australia. In our study, data were collected from im-aging departments (n = 91), with a response rate of 65% of the national total. All CT scanners ranged from 1 to 256 slices. The 75th percentile for the DLP of the head, chest, and abdomen-pelvis CT scan in Lebanon was 1426, 646, and 967 mGy cm respectively. A significant difference in mean DLP of the chest and abdomen-pelvis CT in different governorates was noted with north Lebanon having the highest levels (604 and 882 mGy cm respec-tively) (p < 0.05). When benchmarked with 18 different countries, Lebanon ranked 2nd, 3rd, and 4th highest in 75th percentile DLP for head, chest, and abdomen-pelvis CT scans respectively. In conclusion, the established Lebanese NDRL for adult routine CT scans of head, chest, and abdomen-pelvis were significantly higher than the reported international radiation dose thresholds. This demonstrates a great scope for radiation dose reduction and the need for urgent intervention of DRL to optimize CT scanning procedures and protocols in Lebanon.
引用
收藏
页数:6
相关论文
共 39 条
  • [31] ACEP's Recommendations for Brain Computed Tomography Scan in Adult Minor Head Trauma Patients; a Diagnostic Accuracy Study
    Mohammaddoust, Mohammad
    Chokan, Niaz-Mohammad Jafari
    Farahi, Seyedeh Maryam Moshirian
    Tavakolian, Ayoub
    Foroughia, Mandi
    ARCHIVES OF ACADEMIC EMERGENCY MEDICINE, 2020, 8 (01)
  • [32] Establishment of institutional diagnostic reference levels for 6 adult computed tomography examinations: Results from preliminary data collection
    Albahiti, Sarah K.
    Barnawi, Rashid A.
    Alsafi, Khalid
    Khafaji, Mawya
    Aljondi, Rowa
    Alghamdi, Salem Saeed
    Awan, Zuhier
    Sulieman, Abdelmoneim
    Jafer, Mustafa
    Tamam, Nissren
    Tajaldeen, Abdulrahman
    Mattar, Essam H.
    Al-Malki, Khaled Mudis
    Bradley, David
    RADIATION PHYSICS AND CHEMISTRY, 2022, 201
  • [33] Nationwide survey of radiation exposure during pediatric computed tomography examinations and proposal of age-based diagnostic reference levels for Japan
    Takei, Yasutaka
    Miyazaki, Osamu
    Matsubara, Kosuke
    Shimada, Yoshiya
    Muramatsu, Yoshihisa
    Akahane, Keiichi
    Fujii, Keisuke
    Suzuki, Shoichi
    Koshida, Kichiro
    PEDIATRIC RADIOLOGY, 2016, 46 (02) : 280 - 285
  • [34] NATIONAL DIAGNOSTIC REFERENCE LEVELS AND ACHIEVABLE DOSES FOR 13 ADULT CT PROTOCOLS AND A PAEDIATRIC HEAD CT PROTOCOL: NATIONAL SURVEY OF KOREAN HOSPITALS
    Kim, Jung Su
    Lee, Sang Kyung
    Kim, Sun-Ki
    Yoo, Seung-Min
    Kim, Jung Min
    Yoon, Sang-Wook
    RADIATION PROTECTION DOSIMETRY, 2019, 187 (02) : 220 - 229
  • [35] PEDIATRIC HEAD CT EXPOSURE DOSES IN TUNISIA: A PILOT STUDY TOWARDS THE ESTABLISHMENT OF NATIONAL DIAGNOSTIC REFERENCE LEVELS
    Bouaoun, Abir
    Ben Omrane, Latifa
    Mogaadi, Mohamed
    Khomsi, Wiem Douira
    Zidi, Asma
    Hammou, Azza
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (02) : 241 - 251
  • [36] DETERMINATION OF NATIONAL DIAGNOSTIC REFERENCE LEVELS IN COMPUTED TOMOGRAPHY EXAMINATIONS OF IRAN BY A NEW QUALITY CONTROL-BASED DOSE SURVEY METHOD
    Sohrabi, Mehdi
    Parsi, Masoumeh
    Mianji, Fereidoun
    RADIATION PROTECTION DOSIMETRY, 2018, 179 (03) : 206 - 215
  • [37] Proposed national diagnostic reference levels for computed tomography examinations based on clinical indication, patient gender and size and the use of contrast in Lebanon
    Hakme, M.
    Rizk, C.
    Francis, Z.
    Fares, G.
    RADIOPROTECTION, 2023, 58 (02) : 113 - 121
  • [38] Whole-Body Computed Tomography During Initial Management and Mortality Among Adult Severe Blunt Trauma Patients: A Nationwide Cohort Study
    Tsutsumi, Yusuke
    Fukuma, Shingo
    Tsuchiya, Asuka
    Yamamoto, Yosuke
    Fukuhara, Shunichi
    WORLD JOURNAL OF SURGERY, 2018, 42 (12) : 3939 - 3946
  • [39] Size-specific dose estimates of adult, chest computed tomography examinations: Comparison of Chinese and updated 2017 American College of Radiology diagnostic reference levels based on the water-equivalent diameter
    Hu, Xiaoyan
    Gou, Jie
    Lin, Wei
    Zou, Chunhua
    Li, Wenbo
    PLOS ONE, 2021, 16 (09):