Poor practice and governance in Lebanese national diagnostic reference levels of adult head and body computed tomography: A nationwide study

被引:5
|
作者
Karout, Lina [1 ]
Khalife, Sarah [2 ]
Awad, Mohamad Fawzi [2 ]
Arnous, Ghida [2 ]
Roumie, Mohamad [3 ]
Rawashdeh, Mohammad Ahmmad [4 ]
Saade, Charbel [5 ]
机构
[1] Amer Univ Beirut, Radiol Dept, POBox 11-0236, Beirut 11072020, Lebanon
[2] Amer Univ Beirut, Fac Hlth Sci, Med Imaging Sci, POB 11-0236, Beirut 11072020, Lebanon
[3] Natl Council Sci Res, Lebanese Atom Energy Commiss, Airport Rd,POB 11-8281, Beirut 11072020, Lebanon
[4] Jordan Univ Sci & Technol Irbid, Dept Allied Med Sci, POB 3030, Irbid 22110, Jordan
[5] Univ Coll Cork, Fac Hlth Sci, Med Imaging Sci, Coll Rd, Cork T12 K8AF, Ireland
关键词
Radiation protection; Radiation dosage; Tomography; X-ray computed; Radiation exposure; DOSE MANAGEMENT; X-RAY; CT; ESTABLISHMENT; OPTIMIZATION; RADIOLOGY; EVALUATE; VALUES;
D O I
10.1016/j.radphyschem.2021.109888
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Lebanon has one of the highest number of computed tomography (CT) scanners per capita in the world which could likely be one of the causative factors of its high cancer incidence. In this study, we aimed to establish a national diagnostic reference level (NDRL) in adult CT examinations of the head and body in Lebanon. Dose Length Product (DLP) (n = 2730) were recorded in 91 hospitals/centers in Lebanon for head, chest, and abdomen-pelvis CT. Data was obtained from adult patients (>= 18 years) with a weight range of 75-80 kg, from January 2018 until December 2019. Then, the median, mean and 75th percentile of the DLP was calculated for each anatomical region. NDRL was reported as the 75th percentile. Then, the established NDRL was bench-marked with international countries as the USA, UK, and Australia. In our study, data were collected from im-aging departments (n = 91), with a response rate of 65% of the national total. All CT scanners ranged from 1 to 256 slices. The 75th percentile for the DLP of the head, chest, and abdomen-pelvis CT scan in Lebanon was 1426, 646, and 967 mGy cm respectively. A significant difference in mean DLP of the chest and abdomen-pelvis CT in different governorates was noted with north Lebanon having the highest levels (604 and 882 mGy cm respec-tively) (p < 0.05). When benchmarked with 18 different countries, Lebanon ranked 2nd, 3rd, and 4th highest in 75th percentile DLP for head, chest, and abdomen-pelvis CT scans respectively. In conclusion, the established Lebanese NDRL for adult routine CT scans of head, chest, and abdomen-pelvis were significantly higher than the reported international radiation dose thresholds. This demonstrates a great scope for radiation dose reduction and the need for urgent intervention of DRL to optimize CT scanning procedures and protocols in Lebanon.
引用
收藏
页数:6
相关论文
共 39 条
  • [21] National diagnostic reference levels based on clinical indications and patient size for adults' computed tomography in the Kingdom of Bahrain
    Hasan, Nada
    Rizk, Chadia
    Babikir, Esameldeen
    RADIATION PHYSICS AND CHEMISTRY, 2022, 197
  • [22] Estimation of diagnostic reference levels for children computed tomography: A study in Tehran, Iran
    Afzalipour, R.
    Abdollahi, H.
    Hajializadeh, M. S.
    Jafari, S.
    Mahdavi, S. R.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2019, 17 (03): : 407 - 413
  • [23] DERIVATION OF LOCAL DIAGNOSTIC REFERENCE LEVELS FOR COMMON ADULT COMPUTED TOMOGRAPHY EXAMINATIONS IN MOROCCAN HOSPITAL
    Benmessaoud, M.
    Housni, A.
    Elmabrouki, M.
    Essasnaoui, F.
    Sadiki, N.
    Dadouch, A.
    Labzour, A.
    RADIATION PROTECTION DOSIMETRY, 2021, 194 (04) : 208 - 213
  • [24] Establishment of national diagnostic dose reference levels (DRLs) for routine computed tomography examinations in Jordan
    Radaideh, Khaldoon
    Al-Radaideh, Ali
    Ramli, Ramzun Maizan
    Saleh, Abdallah
    Alshayeb, Rasha
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2023, 29 (01): : 26 - 34
  • [25] Updating national diagnostic reference levels for computed tomography in Greece: Challenges on patient protection optimisation
    Simantirakis, George
    Hourdakis, Costas J.
    Kalathaki, Maria
    Liotsou, Vasiliki
    Nikolaou, Magda
    Pafilis, Christos
    Thrapsanioti, Zoi
    Tritakis, Panagiotis
    Carinou, Eleftheria
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 175
  • [26] A survey of local diagnostic reference levels for the head, thorax, abdomen and pelvis computed tomography in Norway and Canada
    Tonkopi, Elena
    Wikan, Eline Jahre
    Hovland, Tor Olav
    Hogset, Sivert
    Kofod, Thomas Alexander
    Sefenu, Selasi K.
    Hughes-Ryan, Emily
    d'Entremont-O'Connell, Dakota
    Gunn, Catherine
    Holter, Tanja
    Johansen, Safora
    ACTA RADIOLOGICA OPEN, 2022, 11 (10)
  • [27] Diagnostic reference levels for common pediatric computed tomography studies: A retrospective study.
    Khafaji, Mawya
    Barnawi, Rashid
    Amoudi, Salma
    Gabbani, Hassan
    Alhazmi, Rayan
    Ahyad, Rayan
    Alsafi, Khalid
    Saeedi, Khuld
    Salah, Hassan
    Tamam, Nissren
    Bradley, David
    Albahiti, Sarah
    Sulieman, Abdelmoneim
    RADIATION PHYSICS AND CHEMISTRY, 2024, 215
  • [28] Clinical indication-based diagnostic reference levels for paediatric head computed tomography examinations in Kano Metropolis, northwestern Nigeria
    Zira, D. Joseph
    Yahaya, T. Haruna
    Umar, M. S.
    Nkubli, B. F.
    Chukwuemeka, N. C.
    Sidi, M.
    Emmanuel, R.
    Ibrahim, F. Z.
    Laushugno, S. S.
    Ogenyi, A. P.
    RADIOGRAPHY, 2021, 27 (02) : 617 - 621
  • [29] Diagnostic reference levels (DRLs) for chest radiography, non-contrast head computed tomography and mammography examinations in Nigeria: review of national data
    Eze, Kenneth Chukwudi
    Uduma, Felix
    Omidiji, Olubukola Abeni
    Ibekwe, Nkemakolam Kenneth
    Ahidjo, Ahmed
    Ibinaiye, Philip Oluleke
    Anas, Ismail
    Itanyi, Ukamaka Dorothy
    Igbinedion, Blessing Ose-Emenim
    Ogbole, Godwin Inalegwu
    Awosanya, Gbolahan Olusegun
    CHINESE JOURNAL OF ACADEMIC RADIOLOGY, 2022, 5 (02) : 99 - 106
  • [30] Diagnostic reference levels and achievable doses for common computed tomography examinations: Results from the Japanese nationwide dose survey
    Matsunaga, Yuta
    Chida, Koichi
    Kondo, Yuya
    Kobayashi, Kenichi
    Kobayashi, Masanao
    Minami, Kazuyuki
    Suzuki, Shoichi
    Asada, Yasuki
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1094):