Poor practice and governance in Lebanese national diagnostic reference levels of adult head and body computed tomography: A nationwide study

被引:5
|
作者
Karout, Lina [1 ]
Khalife, Sarah [2 ]
Awad, Mohamad Fawzi [2 ]
Arnous, Ghida [2 ]
Roumie, Mohamad [3 ]
Rawashdeh, Mohammad Ahmmad [4 ]
Saade, Charbel [5 ]
机构
[1] Amer Univ Beirut, Radiol Dept, POBox 11-0236, Beirut 11072020, Lebanon
[2] Amer Univ Beirut, Fac Hlth Sci, Med Imaging Sci, POB 11-0236, Beirut 11072020, Lebanon
[3] Natl Council Sci Res, Lebanese Atom Energy Commiss, Airport Rd,POB 11-8281, Beirut 11072020, Lebanon
[4] Jordan Univ Sci & Technol Irbid, Dept Allied Med Sci, POB 3030, Irbid 22110, Jordan
[5] Univ Coll Cork, Fac Hlth Sci, Med Imaging Sci, Coll Rd, Cork T12 K8AF, Ireland
关键词
Radiation protection; Radiation dosage; Tomography; X-ray computed; Radiation exposure; DOSE MANAGEMENT; X-RAY; CT; ESTABLISHMENT; OPTIMIZATION; RADIOLOGY; EVALUATE; VALUES;
D O I
10.1016/j.radphyschem.2021.109888
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Lebanon has one of the highest number of computed tomography (CT) scanners per capita in the world which could likely be one of the causative factors of its high cancer incidence. In this study, we aimed to establish a national diagnostic reference level (NDRL) in adult CT examinations of the head and body in Lebanon. Dose Length Product (DLP) (n = 2730) were recorded in 91 hospitals/centers in Lebanon for head, chest, and abdomen-pelvis CT. Data was obtained from adult patients (>= 18 years) with a weight range of 75-80 kg, from January 2018 until December 2019. Then, the median, mean and 75th percentile of the DLP was calculated for each anatomical region. NDRL was reported as the 75th percentile. Then, the established NDRL was bench-marked with international countries as the USA, UK, and Australia. In our study, data were collected from im-aging departments (n = 91), with a response rate of 65% of the national total. All CT scanners ranged from 1 to 256 slices. The 75th percentile for the DLP of the head, chest, and abdomen-pelvis CT scan in Lebanon was 1426, 646, and 967 mGy cm respectively. A significant difference in mean DLP of the chest and abdomen-pelvis CT in different governorates was noted with north Lebanon having the highest levels (604 and 882 mGy cm respec-tively) (p < 0.05). When benchmarked with 18 different countries, Lebanon ranked 2nd, 3rd, and 4th highest in 75th percentile DLP for head, chest, and abdomen-pelvis CT scans respectively. In conclusion, the established Lebanese NDRL for adult routine CT scans of head, chest, and abdomen-pelvis were significantly higher than the reported international radiation dose thresholds. This demonstrates a great scope for radiation dose reduction and the need for urgent intervention of DRL to optimize CT scanning procedures and protocols in Lebanon.
引用
收藏
页数:6
相关论文
共 39 条
  • [1] Diagnostic Reference Levels for computed tomography in Austria: A 2018 nationwide survey on adult patients
    Wachabauer, David
    Roethlin, Florian
    Moshammer, Hanns Michael
    Homolka, Peter
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 125
  • [2] DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC HEAD COMPUTED TOMOGRAPHY IN MOROCCO: A NATIONWIDE SURVEY
    Benmessaoud, M.
    Dadouch, A.
    Talbi, M.
    Tahiri, M.
    El-ouardi, Y.
    RADIATION PROTECTION DOSIMETRY, 2020, 191 (04) : 400 - 408
  • [3] Establishment of national diagnostic reference levels for computed tomography procedures in Sri Lanka: first nationwide dose survey
    Amalaraj, T.
    Satharasinghe, Duminda
    Pallewatte, Aruna
    Jeyasugiththan, Jeyasingam
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (02)
  • [4] Establishing Local Diagnostic Reference Levels for Head Computed Tomography Examinations
    Modlinska, Sandra
    Rojek, Marcin
    Bielowka, Michal
    Kufel, Jakub
    BIOMEDICINES, 2024, 12 (11)
  • [5] Estimation of diagnostic reference levels for pediatric head computed tomography in Yaoundé
    Kamdem, Eddy F.
    Fotue, Alain J.
    Kouam, Brice B. F.
    Abogo, Serge
    Samba, Odette N.
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (03) : 259 - 263
  • [6] Establishing national paediatric computed tomography diagnostic reference levels in Ghana
    Shirazu, Issahaku
    Sackey, Theophilus A.
    Edziah, Raymond
    Boateng, Yaw Mensah
    Schandorf, Cyril.
    HEALTH AND TECHNOLOGY, 2024, 14 (06) : 1187 - 1198
  • [7] 2021 NATIONAL DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC COMPUTED TOMOGRAPHY IN EGYPT
    Abdou, Sayed E.
    Salama, Dina H.
    Ahmad, Khaled A.
    Sallam, Abdelsattar M.
    El-Sayed, El-Sayed Mahmoud
    Talaat, M. S.
    El-Farrash, Rania A.
    Vassileva, J.
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (07) : 423 - 433
  • [8] Diagnostic reference levels for adult computed tomography at the University Hospital Center of Marrakech (Morocco)
    Khajmi, H.
    Mounir, A.
    Tounsi, A.
    Lhouceine, O.
    RADIOPROTECTION, 2025, 60 (01) : 44 - 49
  • [9] An Environmental Scan of the National and Provincial Diagnostic Reference Levels in Canada for Common Adult Computed Tomography Scans
    Ferderbar, Michelle Linda
    Doyle, Thomas E.
    Samavi, Reza
    Koff, David
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2019, 70 (02): : 119 - 124
  • [10] National diagnostic reference levels have a lot of potential but a long way to go-a systematic review of the current status of adult diagnostic reference levels in head, chest and abdominopelvic computed tomography
    Awad, Mohamad Fawzi
    Karout, Lina
    Arnous, Ghida
    Rawashdeh, Mohammad Ahmmad
    Hneiny, Layal
    Saade, Charbel
    JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (03) : R71 - R98