IMPROVING DISPLACEMENT SIGNAL-TO-NOISE RATIO FOR LOW-SIGNAL RADIATION FORCE ELASTICITY IMAGING USING BAYESIAN TECHNIQUES

被引:13
作者
Dumont, Douglas M. [1 ]
Walsh, Kristy M. [1 ]
Byram, Brett C. [1 ]
机构
[1] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37235 USA
关键词
Displacement estimation; Elasticity imaging; Shear wave; Bayes; Medical imaging; Elastography; Ultrasound; SHEAR-WAVE ELASTOGRAPHY; IN-VIVO; ULTRASOUND ELASTOGRAPHY; PHYSIOLOGICAL MOTION; B-MODE; TRACKING; STIFFNESS; LIVER; FEASIBILITY; FIBROSIS;
D O I
10.1016/j.ultrasmedbio.2016.03.004
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Radiation force-based elasticity imaging is currently being investigated as a possible diagnostic modality for a number of clinical tasks, including liver fibrosis staging and the characterization of cardiovascular tissue. In this study, we evaluate the relationship between peak displacement magnitude and image quality and propose using a Bayesian estimator to overcome the challenge of obtaining viable data in low displacement signal environments. Displacement data quality were quantified for two common radiation force-based applications, acoustic radiation force impulse imaging, which measures the displacement within the region of excitation, and shear wave elasticity imaging, which measures displacements outside the region of excitation. Performance as a function of peak displacement magnitude for acoustic radiation force impulse imaging was assessed in simulations and lesion phantoms by quantifying signal-to-noise ratio (SNR) and contrast-to-noise ratio for varying peak displacement magnitudes. Overall performance for shear wave elasticity imaging was assessed in ex vivo chicken breast samples by measuring the displacement SNR as a function of distance from the excitation source. The results show that for any given displacement magnitude level, the Bayesian estimator can increase the SNR by approximately 9 dB over normalized cross-correlation and the contrast-to-noise ratio by a factor of two. We conclude from the results that a Bayesian estimator may be useful for increasing data quality in SNR-limited imaging environments. (E-mail: brett.c.byram@vanderbilt.edu) (C) 2016 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1986 / 1997
页数:12
相关论文
共 51 条
[1]  
Athanasiou A, 2015, ULTRASCHALL MED
[2]   Feasibility of Near Real-Time Lesion Assessment During Radiofrequency Catheter Ablation in Humans Using Acoustic Radiation Force Impulse Imaging [J].
Bahnson, Tristram D. ;
Eyerly, Stephanie A. ;
Hollender, Peter J. ;
Doherty, Joshua R. ;
Kim, Young-Joong ;
Trahey, Gregg E. ;
Wolf, Patrick D. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (12) :1275-1283
[3]   A generalized Gaussian image model for edge-preserving MAP estimation [J].
Bournan, Charles ;
Sauer, Ken .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1993, 2 (03) :296-310
[4]   Bayesian Speckle Tracking. Part I: An Implementable Perturbation to the Likelihood Function for Ultrasound Displacement Estimation [J].
Byram, Brett ;
Trahey, Gregg E. ;
Palmeri, Mark .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (01) :132-143
[5]   Bayesian Speckle Tracking. Part II: Biased Ultrasound Displacement Estimation [J].
Byram, Brett ;
Trahey, Gregg E. ;
Palmeri, Mark .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (01) :144-157
[6]  
Carlson JE, 2004, HELS UNIV TECHNOL S, V46, P260
[7]   Statistical Analysis of Shear Wave Speed in the Uterine Cervix [J].
Carlson, Lindsey C. ;
Feltovich, Helen ;
Palmeri, Mark L. ;
Munoz del Rio, Alejandro ;
Hall, Timothy J. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (10) :1651-1660
[8]   A Hybrid Displacement Estimation Method for Ultrasonic Elasticity Imaging [J].
Chen, Lujie ;
Housden, R. James ;
Treece, Graham M. ;
Gee, Andrew H. ;
Prager, Richard W. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (04) :866-882
[9]   NON-INVASIVE IN VIVO CHARACTERIZATION OF HUMAN CAROTID PLAQUES WITH ACOUSTIC RADIATION FORCE IMPULSE ULTRASOUND: COMPARISON WITH HISTOLOGY AFTER ENDARTERECTOMY [J].
Czernuszewicz, Tomasz J. ;
Homeister, Jonathon W. ;
Caughey, Melissa C. ;
Farber, Mark A. ;
Fulton, Joseph J. ;
Ford, Peter F. ;
Marston, William A. ;
Vallabhaneni, Raghuveer ;
Nichols, Timothy C. ;
Gallippi, Caterina M. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (03) :685-697
[10]   ESTIMATION OF LARGE-SCALE ORGAN MOTION IN B-MODE ULTRASOUND IMAGE SEQUENCES: A SURVEY [J].
De Luca, Valeria ;
Szekely, Gabor ;
Tanner, Christine .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (12) :3044-3062