Short-term outcomes of a modified technique for small-incision scleral-fixated intraocular lens implantation using Gore-Tex sutures

被引:5
作者
Huang, Ching-Wen [1 ]
Tsai, Chia-Ying [1 ,2 ,3 ]
Lai, Tso-Ting [1 ,4 ]
机构
[1] Natl Taiwan Univ Hosp, Dept Ophthalmol, 7 Chung Shan S Rd, Taipei 100, Taiwan
[2] Fu Jen Catholic Univ, Dept Ophthalmol, Fu Jen Catholic Univ Hosp, New Taipei, Taiwan
[3] Fu Jen Catholic Univ, Coll Med, Sch Med, New Taipei, Taiwan
[4] Natl Taiwan Univ, Coll Med, Grad Inst Clin Med, Taipei, Taiwan
关键词
Gore-Tex suture; Inadequate capsular support; Scleral-fixated intraocular lens; Small incision; Surgically induced astigmatism; CLINICAL-OUTCOMES; DISLOCATION; SCLEROTOMY; TILT;
D O I
10.1007/s00417-021-05201-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To report the short-term outcomes of a modified small-incision technique for implantation of scleral-fixated intraocular lenses (IOLs) using Gore-Tex sutures. Methods A retrospective, interventional, consecutive case series was conducted. From June 2019 to February 2020, 10 patients underwent small-incision scleral-fixated IOL implantation using Gore-Tex sutures at a tertiary referral center. Visual and anatomical outcomes and complications were recorded with a minimum follow-up period of 3 months. Surgically induced astigmatism (SIA) and IOL-induced astigmatism were measured. Results The mean follow-up duration (range) was 396 (240-573) days. Best-corrected visual acuity improved significantly from logarithm of the minimal angle of resolution (logMAR) 0.88 +/- 0.65 (Snellen equivalent: 20/153) preoperation to logMAR = 0.30 +/- 0.51 (Snellen equivalent: 20/40) at final follow-up (P = .008). The estimated SIA and IOL-induced astigmatism were 0.61 diopters (D) +/- 0.49D and 0.40D +/- 0.36D, respectively. No intraoperative complications occurred. The postoperative complications, which included ocular hypertension (20%), cystoid macular edema (30%), and vitreous hemorrhage (20%), were transient and resolved with topical medication. Conclusions The modified small-incision technique for implantation of scleral-fixated IOLs using Gore-Tex sutures was well tolerated in all patients, with favorable postoperative visual outcomes and minimal SIA and IOL-induced astigmatism.
引用
收藏
页码:1889 / 1896
页数:8
相关论文
共 35 条
[1]   Scleral buckling biomaterials and implants for retinal detachment surgery [J].
Baino, Francesco .
MEDICAL ENGINEERING & PHYSICS, 2010, 32 (09) :945-956
[2]   4-POINT FIXATION TECHNIQUE FOR SUTURED POSTERIOR CHAMBER INTRAOCULAR LENSES [J].
BERGREN, RL .
ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (11) :1485-1487
[3]   ONE-YEAR OUTCOMES OF A NOVEL SURGICAL APPROACH FOR FIXATION OF A POSTERIOR CHAMBER INTRAOCULAR LENS USING GORE-TEX SUTURE [J].
Bonnell, Alyssa C. ;
Mantopoulos, Dimosthenis ;
Fine, Howard F. ;
Shah, Sumit P. ;
Wheatley, H. Matthew ;
Prenner, Jonathan L. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2020, 40 (05) :833-837
[4]   Scleral Fixation of Intraocular Lenses with Gore-Tex Suture Refractive Outcomes and Comparison of Lens Power Formulas [J].
Botsford, Benjamin W. ;
Williams, Andrew M. ;
Conner, Ian P. ;
Martel, Joseph N. ;
Eller, Andrew W. .
OPHTHALMOLOGY RETINA, 2019, 3 (06) :468-472
[5]   Unilateral Triangular Eyelet Disruption of Scleral-Fixed enVista Lens [J].
Chen, Kuan-Jen ;
Sun, Chi-Chin ;
Sun, Ming-Hui .
OPHTHALMOLOGY RETINA, 2019, 3 (08) :680-680
[6]   Risk Factors and Incidence of Macular Edema after Cataract Surgery A Database Study of 81 984 Eyes [J].
Chu, Colin J. ;
Johnston, Robert L. ;
Buscombe, Charlotte ;
Sallam, Ahmed B. ;
Mohamed, Queresh ;
Yang, Yit C. .
OPHTHALMOLOGY, 2016, 123 (02) :316-323
[7]   Transconjunctival Approach to Scleral Fixation of Posterior Chamber Intraocular Lenses Using Gore-Tex Suture [J].
Cutler, Nathan E. ;
Sridhar, Jayanth ;
Khan, Mohammed Ali ;
Gupta, Omesh P. ;
Fineman, Mitchell S. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (05) :1003-1005
[8]   Sutureless intrascleral fixation using different three-piece posterior chamber intraocular lenses: a literature review of surgical techniques in cases of insufficient capsular support and a retrospective multicentre study [J].
Czajka, Marcin Piotr ;
Frajdenberg, Agata ;
Stopa, Marcin ;
Pabin, Tomasz ;
Johansson, Bjorn ;
Jakobsson, Gunnar .
ACTA OPHTHALMOLOGICA, 2020, 98 (03) :224-236
[9]   Scleral fixation of a foldable intraocular lens with polytetrafluoroethylene sutures through a Hoffman pocket [J].
Das, Sudeep ;
Nicholson, Maneck ;
Deshpande, Kalyani ;
Kummelil, Mathew Kurian ;
Nagappa, Somshekar ;
Shetty, Bhujang K. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (07) :955-960
[10]   Opacification of Akreos Hydrophilic Acrylic Lens After Retinal Detachment Repair with Silicone Oil Tamponade: A Case Report [J].
Gregori, Ninel Z. ;
Echegaray, Jose J. ;
Flynn, Harry W., Jr. .