Investigating Optimum Cooling Set Point Temperature and Air Velocity for Thermal Comfort and Energy Conservation in Mixed-Mode Buildings in India

被引:4
作者
Gokarakonda, Sriraj [1 ]
van Treeck, Christoph [2 ]
Rawal, Rajan [3 ]
机构
[1] Wuppertal Inst Climate Environm & Energy, Energy Transport & Climate Policy Div, D-42103 Wuppertal, Germany
[2] Rhein Westfal TH Aachen, E3D Inst Energy Efficiency & Sustainable Bldg, D-52074 Aachen, Germany
[3] CEPT Univ, Ctr Adv Res Bldg Sci & Energy CARBSE, Ahmadabad 380009, Gujarat, India
关键词
elevated air speed; thermal comfort; mixed-mode buildings; set point temperature; energy consumption in buildings; NATURALLY VENTILATED BUILDINGS; BEHAVIORAL ADAPTATION; COMPOSITE CLIMATE; OFFICES; ZONES; FIELD;
D O I
10.3390/en15062259
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In warm and hot climates, ceiling fans and/or air conditioners (ACs) are used to maintain thermal comfort. Ceiling fans provide air movement near the skin, which enhances the evaporation of sweat, reduces heat stress, and enhances thermal comfort. This is also called the cooling effect. However, AC usage behaviour and the effects of elevated air speed through the use of ceiling fans on indoor operative temperature during AC usage are not widely studied. This study investigated the optimum AC (cooling) set point temperature and air velocity necessary for maintaining thermal comfort while achieving energy conservation, in mixed-mode buildings in India, through field studies by using used custom-built Internet of Things (IOT) devices. In the current study, the results indicate a 79% probability that comfort conditions can be maintained by achieving a temperature drop of 3K. If this drop can be achieved, as much as possible, through passive measures, the duration of AC operation and its energy consumption are reduced, at least by 67.5 and 58.4%, respectively. During the air-conditioned period, there is a possibility that the cooing effect is reduced because of increase in operative temperature due to ceiling fan operation. Therefore, the optimum solution is to maintain the highest AC set point and minimum fan speed setting that are acceptable.
引用
收藏
页数:27
相关论文
共 74 条
[1]   Clustering and statistical analyses of air-conditioning intensity and use patterns in residential buildings [J].
An, Jingjing ;
Yan, Da ;
Hong, Tianzhen .
ENERGY AND BUILDINGS, 2018, 174 :214-227
[2]  
[Anonymous], 2021, RTCLIB
[3]  
ASHRAE, 2010, ANSI/ASHRAE 55:2010
[4]   Transient three-dimensional CFD modelling of ceiling fans [J].
Babich, Francesco ;
Cook, Malcolm ;
Loveday, Dennis ;
Rawal, Rajan ;
Shukla, Yash .
BUILDING AND ENVIRONMENT, 2017, 123 :37-49
[5]   Studying the features of air flow induced by a room ceiling-fan [J].
Bassiouny, Ramadan ;
Korah, Nader S. .
ENERGY AND BUILDINGS, 2011, 43 (08) :1913-1918
[6]   Development of reference building models for India [J].
Bhatnagar, Mayank ;
Mathur, Jyotirmay ;
Garg, Vishal .
JOURNAL OF BUILDING ENGINEERING, 2019, 21 :267-277
[7]   Occupant satisfaction in mixed-mode buildings [J].
Brager, Gail ;
Baker, Lindsay .
BUILDING RESEARCH AND INFORMATION, 2009, 37 (04) :369-380
[8]  
Bureau of Energy Efficiency, 2017, ENERGY CONSERVATION
[9]  
Bureau of Energy Efficiency, 2018, ECO NIW SAMH 2018 EN
[10]   Air movement acceptability limits and thermal comfort in Brazil's hot humid climate zone [J].
Candido, C. ;
de Dear, R. J. ;
Lamberts, R. ;
Bittencourt, L. .