Quantitative evaluation of the accuracy and variance of individual pixels in a scientific CMOS (sCMOS) camera for computational imaging

被引:9
|
作者
Watanabe, Shigeo [1 ]
Takahashi, Teruo [1 ]
Bennett, Keith [1 ]
机构
[1] Hamamatsu Photon KK, Syst Div, 812 Joko Cho, Hamamatsu, Shizuoka 4313196, Japan
关键词
sCMOS camera; photoresponse uniformity; variance map; photoresponse linearity; dark offset; SINGLE-MOLECULE LOCALIZATION;
D O I
10.1117/12.2251043
中图分类号
TH742 [显微镜];
学科分类号
摘要
The "scientific" CMOS (sCMOS) camera architecture fundamentally differs from CCD and EMCCD cameras. In digital CCD and EMCCD cameras, conversion from charge to the digital output is generally through a single electronic chain, and the read noise and the conversion factor from photoelectrons to digital outputs are highly uniform for all pixels, although quantum efficiency may spatially vary. In CMOS cameras, the charge to voltage conversion is separate for each pixel and each column has independent amplifiers and analog-to-digital converters, in addition to possible pixel-to-pixel variation in quantum efficiency. The "raw" output from the CMOS image sensor includes pixel-to-pixel variability in the read noise, electronic gain, offset and dark current. Scientific camera manufacturers digitally compensate the raw signal from the CMOS image sensors to provide usable images. Statistical noise in images, unless properly modeled, can introduce errors in methods such as fluctuation correlation spectroscopy or computational imaging, for example, localization microscopy using maximum likelihood estimation. We measured the distributions and spatial maps of individual pixel offset, dark current, read noise, linearity, photoresponse non-uniformity and variance distributions of individual pixels for standard, off-the-shelf Hamamatsu ORCA-Flash4.0 V3 sCMOS cameras using highly uniform and controlled illumination conditions, from dark conditions to multiple low light levels between similar to 20 to similar to 1,000 photons/pixel per frame to higher light conditions. We further show that using pixel variance for flat field correction leads to errors in cameras with good factory calibration.
引用
收藏
页数:8
相关论文
共 42 条
  • [1] Evaluation of a scientific CMOS camera for astronomical observations
    Qiu, Peng
    Mao, Yong-Na
    Lu, Xiao-Meng
    Xiang, E.
    Jiang, Xiao-Jun
    RESEARCH IN ASTRONOMY AND ASTROPHYSICS, 2013, 13 (05) : 615 - 628
  • [2] Evaluation of a scientific CMOS camera for astronomical observations
    Peng Qiu
    Yong-Na Mao
    Xiao-Meng Lu
    E Xiang
    Xiao-Jun Jiang
    ResearchinAstronomyandAstrophysics, 2013, 13 (05) : 615 - 628
  • [3] Multiphoton imaging using a quantitative CMOS camera
    Diouf, Mbaye
    Lin, Zixi
    Krishna, Krishangi
    Toussaint, Kimani C., Jr.
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES XXII, 2022, 11965
  • [4] A low-cost high-speed CMOS camera for scientific imaging
    Duke, Daniel J.
    Knast, Thomas
    Thethy, Bhavraj
    Gisler, Luis
    Edgington-Mitchell, Daniel
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (07)
  • [5] Quantitative performance evaluation of a back-illuminated sCMOS camera with 95% QE for super-resolution localization microscopy
    Wang, Yujie
    Zhao, Lingxi
    Hu, Zhe
    Wang, Yina
    Zhao, Zeyu
    Li, Luchang
    Huang, Zhen-Li
    CYTOMETRY PART A, 2017, 91A (12) : 1175 - 1183
  • [6] Evaluation of InGaAs camera for scientific near infrared imaging applications
    Guntupalli, Ravi
    Allen, Robert
    INFRARED AND PHOTOELECTRONIC IMAGERS AND DETECTOR DEVICES II, 2006, 6294
  • [7] Quantitative accuracy of SPECT imaging with a dedicated cardiac camera: Physical phantom experiments
    Pourmoghaddas, Amir
    Wells, R. Glenn
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 147 - 149
  • [8] Quantitative evaluation of Bayer chromatic imaging on the accuracy of photogrammetric measurements
    Zhu, Haibin
    Zhang, Xiaojuan
    Li, Jia
    Chen, Lingfeng
    Liu, Xuejin
    Ma, Qinwei
    Ma, Shaopeng
    MEASUREMENT, 2019, 145 : 724 - 734
  • [9] Evaluation of an X-ray imaging detector based on a CMOS camera with logarithmic response
    Ponchut, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 457 (1-2): : 270 - 278
  • [10] Quantitative evaluation of the computational accuracy for the Monte Carlo calculation of radiative heat transfer
    Wang, Dandan
    Zhou, Huaichun
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2019, 226 : 100 - 114