Time and Space Transition of DC Electric Field Distributions in Oil-Pressboard Composite Insulation in AC/DC Converter Transformer

被引:1
|
作者
Nakane, Ryuichi [1 ]
Kato, Katsumi [2 ]
Hayakawa, Naoki [3 ]
Okubo, Hitoshi [1 ]
机构
[1] Aichi Inst Technol, Toyota, Japan
[2] Niihama Coll, Natl Inst Technol, Niihama, Japan
[3] Nagoya Univ, Nagoya, Aichi, Japan
关键词
HVDC; AC/DC converter transformer; Oil-PB composite insulation systems; Electric field distribution; Charge accumulation; Time transition; Electrical insulation performance; FEM;
D O I
10.1109/icdl.2019.8796800
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It is necessary to enhance an HVDC electrical insulation performance for further introduction of DC electric power systems. In AC/DC converter transformers under DC application, the electric field distributions are distorted due to the deposited charge on pressboard (PB). However, DC electric field stress in oil-PB composite insulation has not yet been clarified in detail. In this paper, we investigated the time and space dependent characteristics of DC electric field stress in oil from DC-on (initial state) to DC steady-state in oil-PB composite insulation systems. As a result, we quantitatively clarified that DC electric field stress strongly depends on the elapsed time and the location in the electric field space in oil. In particular, it was found that the most severe electric field stress in oil for the electrical insulation performance may emerge during the time transition process between initial DC-on to DC steady-state, using an insulated conductor lead and an actual AC/DC converter transformer model.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Time and space transition characteristics of DC electric field stress in oil-pressboard composite insulation systems
    Nakane, Ryuichi
    Kato, Katsumi
    Hayakawa, Naoki
    Okubo, Hitoshi
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2020, 103 (07) : 13 - 21
  • [2] Flow Electrification Characteristics of Oil-pressboard Insulation under AC Superimposed on DC Electric Field
    Chen, Qingguo
    Lin, Lin
    Gao, Yuan
    Li, Jiahui
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (05) : 2915 - 2922
  • [3] Creepage Discharge of Oil-pressboard Insulation in AC-DC Composite Field: Phenomenon and Characteristics
    Qi, Bo
    Wei, Zhen
    Li, Chengrong
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (01) : 237 - 245
  • [4] Electric Field Distribution in Oil-pressboard Insulation under AC-DC Combined Voltages
    Qi, Bo
    Zhao, Xiaolin
    Li, Chengrong
    Wu, Hao
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (04) : 1935 - 1941
  • [6] PD Characteristics of Oil-pressboard Insulation under AC and DC Mixed Voltage
    Li, Junhao
    Han, Xutao
    Liu, Zehui
    Yao, Xiu
    Li, Yanming
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (01) : 444 - 450
  • [7] DC Electric Field Calculation Method of Oil-pressboard Insulation Based on Segmented Charge Superposition
    基于电荷分段映射叠加的油纸绝缘直流电场计算方法
    1600, Chinese Society for Electrical Engineering (40): : 7107 - 7113
  • [8] Time and Space Dependent Characteristics of HVDC Electric Field Stress in Oil-pressboard Composite Insulation Systems
    Nakane, R.
    Kato, K.
    Okubo, H.
    2018 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP), 2018, : 442 - 445
  • [9] Effect of DC electric field on moisture migration characteristics in oil-pressboard
    Yuan, Qing
    Qi, Bo
    Zhao, Jianshe
    Gao, Chunjia
    Yang, Xiao
    Zhang, Shuqi
    Li, Chengrong
    HIGH VOLTAGE, 2021, 6 (04): : 647 - 654
  • [10] Impact of interfacial charge of oil-pressboard insulation on surface flashover voltage under compound AC-DC electric field
    Chen, Yilong
    Qi, Bo
    Li, Chengrong
    Xi, Chaochao
    Dianwang Jishu/Power System Technology, 2014, 38 (04): : 1070 - 1075