The effects of pulsatile flow upon renal tissue perfusion during cardiopulmonary bypass: A comparative study of pulsatile and nonpulsatile flow

被引:56
作者
Kim, HK
Son, HS
Fang, YH
Park, SY
Hwang, CM
Sun, K
机构
[1] Korea Univ, Med Ctr, Dept Thorac & Cardiovasc Surg, Seoul 136705, South Korea
[2] Biomed Sci Brain Korea 21, Seoul, South Korea
[3] Korea Univ, Korea Artificial Organ Ctr, Seoul 136701, South Korea
关键词
D O I
10.1097/01.mat.0000150324.02040.B4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study was conducted to directly compare the effects of pulsatile and nonpulsatile blood flow in the extracorporeal circulation upon renal tissue perfusion by using a tissue perfusion measurement system. A total cardiopulmonary bypass circuit was constructed to accommodate twelve Yorkshire swine, weighing 20similar to30 kg. Animals were randomly assigned to group 1 (n = 6, nonpulsatile centrifugal pump) or group 2 (n = 6, pulsatile T-PLS pump). A tissue perfusion measurement probe (Q-Flow 500) was inserted into the renal parenchymal tissue, and the extracorporeal circulation was maintained for an hour at a pump flow rate of 2 L/min after aortic cross-clamping. Tissue perfusion flow in the kidney was measured before bypass and every 10 minutes after bypass. Renal tissue perfusion flow was substantially higher in the pulsatile group throughout bypass (ranging 48.5-64.1 ml/min/100 g in group 1 vs. 51.0-88.1 ml/min/100 g in group 2). The intergroup difference was significant at 30 minutes (47.5 +/- 18.3 ml/min/100 g in group 1 vs. 83.4 +/- 28.5 ml/min/100 g in group 2; p = 0.026). Pulsatile flow achieves higher levels of tissue perfusion of the kidney during short-term extracorporeal circulation. A further study is required to observe the effects of pulsatile flow upon other vital organs and its longterm significance.
引用
收藏
页码:30 / 36
页数:7
相关论文
共 26 条
  • [1] AKIRA S, 1999, ARTIF ORGANS, V23, P280
  • [2] Acute renal failure following cardiac surgery
    Conlon, PJ
    Stafford-Smith, M
    White, WD
    Newman, MF
    King, S
    Winn, MP
    Landolfo, K
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 1999, 14 (05) : 1158 - 1162
  • [3] The effects of pulsatile and nonpulsatile systemic perfusion on renal sympathetic nerve activity in anesthetized dogs
    Fukae, K
    Tominaga, R
    Tokunaga, S
    Kawachi, Y
    Imaizumi, T
    Yasui, H
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (02) : 478 - 484
  • [4] GIBBON J H Jr, 1954, Minn Med, V37, P171
  • [5] PULSATILE AND NON-PULSATILE CARDIOPULMONARY BYPASS - REVIEW OF A COUNTERPRODUCTIVE CONTROVERSY
    HICKEY, PR
    BUCKLEY, MJ
    PHILBIN, DM
    [J]. ANNALS OF THORACIC SURGERY, 1983, 36 (06) : 720 - 739
  • [6] Kim HM, 2001, 9 ANN M AS SOC CARD, P384
  • [7] Thermodiffusion for continuous quantification of hepatic microcirculation - Validation and potential in liver transplantation
    Klar, E
    Kraus, T
    Bleyl, J
    Newman, WH
    Bowman, HF
    Hofmann, WJ
    Von Kummer, R
    Bredt, M
    Herfarth, C
    [J]. MICROVASCULAR RESEARCH, 1999, 58 (02) : 156 - 166
  • [8] Continuous measurement of porcine renal cortex microcirculation with enhanced thermal diffusion technology
    Kraus, T
    Klar, E
    Osswald, BR
    Fernandes, L
    Mehrabi, A
    Gebhard, MM
    Herfarth, C
    [J]. JOURNAL OF SURGICAL RESEARCH, 1996, 61 (02) : 531 - 536
  • [9] In vivo evaluation of the pulsatile ECLS sysem
    H. S. Lee
    Y. R Rho
    H. S. Lee
    C. M. Hwang
    S. W. Choi
    J. C. Lee
    H. Choi
    S. S. Ahn
    K. Sun
    H. S. Son
    K. J. Baek
    Y. S. Won
    B. G. Min
    [J]. Journal of Artificial Organs, 2003, 6 (1) : 25 - 29
  • [10] Validation of real-time continuous perfusion measurement
    Martin, GT
    Bowman, HF
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (03) : 319 - 325