Optimal Sizing and Assessment of an Islanded Photovoltaic-Battery-Diesel Generator Microgrid Applicable to a Remote School of Bangladesh

被引:36
|
作者
Ishraque, Md Fatin [1 ]
Shezan, Sk A. [2 ]
Nur, Jannati Nabiha [3 ]
Islam, Md Shafiul [1 ]
机构
[1] Varendra Univ, Dept EEE, Rajshahi, Bangladesh
[2] RMIT Univ, Sch Engn, Melbourne, Vic, Australia
[3] Rajshahi Univ Engn & Technol, Dept EEE, Rajshahi, Bangladesh
关键词
Battery; COE; Diesel Generator; HOMER; HRES; NPC; Solar PV; RENEWABLE ENERGY SYSTEM; HYBRID POWER-SYSTEM; RURAL ELECTRIFICATION; PERFORMANCE ANALYSIS; PV; OPTIMIZATION; DESIGN; TECHNOLOGIES;
D O I
10.1002/eng2.12281
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Electricity has become a part and parcel of modern life. The world is constantly developing, and the electricity demand is inevitably increasing with it. It is a big challenge for the power generation organizations to cope up with this increasing demand. For a developing country like Bangladesh, this challenge is even bigger. Bangladesh has many remote areas which are deprived of grid connectivity. In this article, system design and performance evaluation are conducted on a solar battery-based hybrid renewable energy system (HRES) with diesel backup for a school in a remote area located in the northern part of the country, where conventional power grid connectivity is not available. From field survey, a load demand of 10.468kWh/day for a normal working day and a peak demand of 3.3kW are considered in this work for the proposed site. For simulation purpose hybrid optimization model for electric renewable, very well-known software is used. The solar radiation data required for the work are collected from NASA Surface meteorology and Solar Energy database. Analyzing the load requirements and metrological data a solar-battery diesel generator-based HRES is proposed for the school. From the analysis and simulation, the Net Present Cost (NPC) for the proposed system is found USD 6191 with a Cost of Energy (COE) of $0.125/kWh. Further, a comparative study is done and the proposed system can reduce the COE and Green House Gas (GHG) emission of about 29.85% and 69% respectively than the conventional power plants. Finally, a techno-economic analysis is conducted with sensitivity analysis, time series analysis, and multiyear analysis to prove the rigidity of the proposed system.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Optimal sizing of an autonomous photovoltaic/wind/battery/diesel generator microgrid using grasshopper optimization algorithm
    Bukar, Abba Lawan
    Tan, Chee Wei
    Lau, Kwan Yiew
    SOLAR ENERGY, 2019, 188 : 685 - 696
  • [2] Optimal sizing of Solar PV/Battery and Biogas generator in remote microgrid
    Nasir, Mohamad Naim Mohd
    Mutale, Joseph
    2016 51ST INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2016,
  • [3] Optimal Sizing of Isolated Microgrid Containing Photovoltaic/Photothermal/Wind/Diesel/Battery
    Zhao, Guo
    Cao, Tianhua
    Wang, Yudan
    Zhou, Huirui
    Zhang, Chi
    Wan, Chenxi
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2021, 2021
  • [4] A Novel Numerical Algorithm for Optimal Sizing of a Photovoltaic/Wind/Diesel Generator/Battery Microgrid Using Loss of Load Probability Index
    Kazem, Hussein A.
    Khatib, Tamer
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2013, 2013
  • [5] Sizing and Operation Control of a Grid-Interactive Photovoltaic-Battery-Diesel System for Commercial Buildings
    Moji, L. P.
    Kusakana, K.
    Numbi, B. P.
    2020 6TH IEEE INTERNATIONAL ENERGY CONFERENCE (ENERGYCON), 2020, : 401 - 406
  • [6] Optimal sizing of islanded microgrid using pelican optimization algorithm for Kutubdia Island of Bangladesh
    Sagor, Abidur Rahman
    Hazari, Md. Rifat
    Ahmad, Shameem
    Ogliari, Emanuele
    Hossain, Chowdhury Akram
    Jahan, Effat
    Mannan, Mohammad Abdul
    ELECTRIC POWER SYSTEMS RESEARCH, 2025, 238
  • [7] Control strategy of islanded photovoltaic-diesel-storage microgrid with virtual synchronous generator
    Lin Y.
    Zhang J.
    1600, Power System Technology Press (41): : 1277 - 1284
  • [8] A comparative analysis for optimal placement and sizing of distributed generator in grid connected and islanded mode of microgrid
    Kumar A.
    Choudhary N.K.
    Singh N.
    International Journal of Power and Energy Conversion, 2021, 12 (02) : 137 - 152
  • [9] Optimal Operation Method for Microgrid with Wind/PV/Diesel Generator/Battery and Desalination
    Tang, Qingfeng
    Liu, Nian
    Zhang, Jianhua
    JOURNAL OF APPLIED MATHEMATICS, 2014,
  • [10] A new approach for optimal sizing of battery energy storage system for primary frequency control of islanded Microgrid
    Aghamohammadi, Mohammad Reza
    Abdolahinia, Hajar
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 54 : 325 - 333