Evaluation of model-based processing algorithms for averaged transmitral spectral Doppler images

被引:8
|
作者
Hall, AF [1 ]
Nudelman, SP [1 ]
Kovacs, SJ [1 ]
机构
[1] Washington Univ, Sch Med, Div Cardiovasc, Cardiovasc Biophys Lab, St Louis, MO 63110 USA
关键词
diastolic function; left ventricle; Doppler echocardiography; kinematic models; image processing; numerical methods;
D O I
10.1016/S0301-5629(97)00232-9
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In an effort to characterize more fully diastolic function using Doppler echocardiography, we have previously developed an automated method of model-based image processing for spectral Doppler images of transmitral blood how. In this method, maximum velocity envelopes (MVEs) extracted from individual Doppler images are aligned and averaged over several cardiac cycles. The averaged waveform is fit by the solution of a kinematic model of diastolic filling. The results are estimates of the model parameters. As expected, the mean and standard deviation of the model parameter estimates depend on many factors such as noise, the number of cardiac cycles averaged, beat-to-beat variation, waveform shape, observation time and the processing methods used, among others. A comprehensive evaluation of these effects has not been performed to date. A simulation was developed to evaluate the performance of three automated processing methods and to measure the influence of noise, beat-to-beat variation and observation time on the model parameter estimates. The simulation's design and a description and analysis of the three automated processing methods are presented. Of the three methods evaluated, using the inflection point in the acceleration portion of the velocity contour as the first data point to be fit was found to be the most robust method for processing averaged E-wave MVE waveforms. Using this method under nominal conditions, the average bias was measured to be < 3% for each of the model parameters. As expected, the biases and standard deviations of the estimates increased as a result of increased noise levels, increased beat-to-beat variation and decreased observation time. Another important finding was that the effects of noise, beat-to-beat variation and waveform observation time on the parameter estimates are dependent on the location in model parameter space. (C) 1998 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:55 / 66
页数:12
相关论文
共 30 条
  • [21] EFFICIENT DATA-STRUCTURES FOR MODEL-BASED 3-D OBJECT RECOGNITION AND LOCALIZATION FROM RANGE IMAGES
    WANG, W
    IYENGAR, SS
    IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (10) : 1035 - 1045
  • [22] Design and Implementation of a Real-Time Image Processing System Based on Sobel Edge Detection using Model-based Design Methods
    Saidani, Taoufik
    Ghodhbani, Refka
    Ben Ammar, Mohamed
    Kouki, Marouan
    Algarni, Mohammad H.
    Said, Yahia
    Kachoukh, Amani
    Alsuwaylimi, Amjad A.
    Maqbool, Albia
    Abd-Elkawy, Eman H.
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2024, 15 (03) : 273 - 278
  • [23] Diastolic function alteration mechanisms in physiologic hypertrophy versus pathologic hypertrophy are elucidated by model-based Doppler E-wave analysis
    Zhu, Simeng
    Morrell, Thomas
    Apor, Astrid
    Merkely, Bela
    Vago, Hajnalka
    Toth, Attila
    Ghosh, Erina
    Kovacs, Sandor J.
    JOURNAL OF EXERCISE SCIENCE & FITNESS, 2014, 12 (02) : 88 - 95
  • [24] Transition from 2D-to 3D-Images: Modification of Two-Scale Image Model and Image Processing Algorithms
    Chochia, P. A.
    JOURNAL OF COMMUNICATIONS TECHNOLOGY AND ELECTRONICS, 2015, 60 (06) : 678 - 687
  • [25] Transition from 2D- to 3D-images: Modification of two-scale image model and image processing algorithms
    P. A. Chochia
    Journal of Communications Technology and Electronics, 2015, 60 : 678 - 687
  • [26] Model-based image processing derived parameters of ventricular filling:: Can they predict exercise capacity in subjects with chronic heart failure?
    Meyer, TE
    Singh, J
    Karamanoglu, M
    Ehsani, A
    Kovács, S
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1268 - 1269
  • [27] An Approach to Automatic Hard Exudate Detection in Retina Color Images by a Telemedicine System Based on the d-Eye Sensor and Image Processing Algorithms
    Saeed, Emil
    Szymkowski, Maciej
    Saeed, Khalid
    Mariak, Zofia
    SENSORS, 2019, 19 (03):
  • [28] Laser Cutting Defect Recognition Using Conversion of Processing Light Information into Spectrogram Images - Spectroscopic Measurements in Multiple Work Surface Conditions and Extraction of Spectral Data Features Based on Processing Principle -
    Ishiguro, Mizuki
    Fukui, Rui
    Warisawa, Shin'ichi
    Narita, Naoyasu
    Miyoshi, Hironobu
    INTERNATIONAL JOURNAL OF AUTOMATION TECHNOLOGY, 2021, 15 (05) : 728 - 739
  • [29] Evaluation of diastolic function by cardiac MRI in hypertrophic cardiomyopathy: validation of 3D model-based analysis of left ventricular filling curves
    Linda Chu
    Celia P Corona-Villalobos
    Neville Gai
    David Bluemke
    Marcelo Nacif
    Alistair Young
    Theodore Abraham
    Ihab R Kamel
    Stefan L Zimmerman
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [30] Simulation of thermal radiation image processing based on optical technology in volleyball sports evaluation system: An image thermal model analysis☆
    Zhang, Yuliang
    Wang, Tingting
    Yu, Jing
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2025, 60