Development of a Non-scanning Vibrational Sum-Frequency Generation Detected Infrared Super-Resolution Microscope and Its Application to Biological Cells

被引:29
作者
Inoue, Keiichi [1 ]
Fujii, Masaaki [1 ]
Sakai, Makoto [1 ]
机构
[1] Tokyo Inst Technol, Chem Resources Lab, Midori Ku, Yokohama, Kanagawa 2268503, Japan
关键词
Vibrational sum-frequency generation; VSFG; Infrared microscopy; Infrared spectroscopy; Vibrational spectroscopy; Imaging; Cell; SELF-ASSEMBLED MONOLAYERS; IR-MICROSPECTROSCOPY; CARS MICROSCOPE; INTERFACES; RESOLUTION; SPECTROSCOPY; ORIENTATION; SYSTEM;
D O I
10.1366/000370210790918481
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report single-cell infrared (IR) imaging of onion (Allium cepa) root cells using an IR super-resolution microscope based on vibrational sum-frequency generation (VSFG). The resolution of recorded IR images was less than 2 mu m and IR super-resolution was achieved by virtue of the VSFG detection. In addition, IR spectra measurements were successfully performed on distinct intra-cellular assemblies. The IR absorption intensity of the cell nuclear edge and the nucleolus in the 3055-3130 cm I region was stronger than that from the cytoplasmic part. This is because the cell nucleus and nucleolus contain larger amounts of nucleic acid. Thus, the obtained IR spectra reflect differences in chemical composition among different cellular structures. In addition, the ability of our novel IR super-resolution microscope to obtain distinct information on both VSFG and two-photon fluorescence is demonstrated.
引用
收藏
页码:275 / 281
页数:7
相关论文
共 26 条
[1]  
[Anonymous], 2006, Nonlinear Optics
[2]   An epi-detected coherent anti-stokes raman scattering (E-CARS) microscope with high spectral resolution and high sensitivity [J].
Cheng, JX ;
Volkmer, A ;
Book, LD ;
Xie, XS .
JOURNAL OF PHYSICAL CHEMISTRY B, 2001, 105 (07) :1277-1280
[3]   Sum frequency generation microscopy of microcontact-printed mixed self-assembled monolayers [J].
Cimatu, K ;
Baldelli, S .
JOURNAL OF PHYSICAL CHEMISTRY B, 2006, 110 (04) :1807-1813
[4]   Chemical imaging of corrosion: Sum frequency generation imaging microscopy of cyanide on gold at the solid-liquid interface [J].
Cimatu, Katherine ;
Baldelli, Steven .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (25) :8030-8037
[5]   Sum frequency generation imaging of microcontact-printed monolayers derived from aliphatic dithiocarboxylic acids: Contrast based on terminal-group orientation [J].
Cimatu, Katherine ;
Moore, H. Justin ;
Lee, T. Randall ;
Baldelli, Steven .
JOURNAL OF PHYSICAL CHEMISTRY C, 2007, 111 (32) :11751-11755
[6]   Diagnosing benign and malignant lesions in breast tissue sections by using IR-microspectroscopy [J].
Fabian, Heinz ;
Thi, Ngoc Anh Ngo ;
Eiden, Michael ;
Lasch, Peter ;
Schmitt, Juergen ;
Naumann, Dieter .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2006, 1758 (07) :874-882
[7]   Chemical imaging of interfaces by sum frequency microscopy [J].
Flörsheimer, M ;
Brillert, C ;
Fuchs, H .
LANGMUIR, 1999, 15 (17) :5437-5439
[8]   Chemical imaging of interfaces by sum-frequency generation [J].
Flörsheimer, M ;
Brillert, C ;
Fuchs, H .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 1999, 8-9 :335-341
[9]   SUM-FREQUENCY VIBRATIONAL SPECTROSCOPY OF A LANGMUIR FILM - STUDY OF MOLECULAR-ORIENTATION OF A TWO-DIMENSIONAL SYSTEM [J].
GUYOTSIONNEST, P ;
HUNT, JH ;
SHEN, YR .
PHYSICAL REVIEW LETTERS, 1987, 59 (14) :1597-1600
[10]   Sum-frequency generation microscope for opaque and reflecting samples [J].
Hoffmann, DMP ;
Kuhnke, K ;
Kern, K .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (09) :3221-3226