The dosimetric differences in calculating lung SBRT plans on different image data sets: Comparison of the free breathing scan to both the average intensity projection scan and to the sum of calculations on each respiratory phase of the 4DCT scan

被引:2
作者
Liseo, Francesco Gaetani [1 ]
Lautenschlaeger, Tim [1 ]
Ewing, Marvene [1 ]
Langer, Mark [1 ]
机构
[1] Indiana Univ Purdue Univ, Indiana Univ, Canc Ctr, Med Dosimetry Program, 535 Barnhill Dr, Indianapolis, IN 46202 USA
关键词
Lung SBRT; Average intensity projection; Gated radiotherapy; COMPUTED-TOMOGRAPHY; RADIOTHERAPY; MOTION;
D O I
10.1016/j.meddos.2018.06.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The purpose of this study is to evaluate the dosimetric differences to the lung internal target volume (ITV) in stereotactic body radiation therapy (SBRT) when calculated on the free breathing (FB) scan in comparison to calculations on the average intensity projection (ALP) scan as well as the sum of dose calculated on each of the treated respiratory phases. The clinical treatment plan data for 16 SBRT lung patients were retrospectively chosen for this study, 5 of which were 30% to 70% respiratory phase gated. All patients had ITV contours and fixed monitor units from the treatment approved plan copied over to each scan on which calculations were to be made. The results of this study yielded 6 out of 16 patients with greater than or equal to 2% difference in ITV maximum dose (D-0) and 2 of 16 patients with greater than or equal to 2% difference in ITV minimum dose (D-100). The range of ITV dose differences for these 8 patients was 2% to 4.7% with no patients exceeding a 5% difference in D-0 or D-100. None of the patients had greater than or equal to 2% difference in ITV mean dose (D-mean). Sixty-three percent of patients with greater than 2% ITV dose difference in any of the categories reviewed were those patients with greater than 1 cm gross tumor motion. This study concluded that in order to reduce uncertainty in dose to the ITV, tumor motion should be assessed at simulation and limited to below 1 cm in any direction if possible. (C) 2018 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:291 / 299
页数:9
相关论文
共 6 条
[1]   QUANTIFYING INTERFRACTION AND INTRAFRACTION TUMOR MOTION IN LUNG STEREOTACTIC BODY RADIOTHERAPY USING RESPIRATION-CORRELATED CONE BEAM COMPUTED TOMOGRAPHY [J].
Bissonnette, Jean-Pierre ;
Franks, Kevin N. ;
Purdie, Thomas G. ;
Moseley, Douglas J. ;
Sonke, Jan-Jakob ;
Jaffray, David A. ;
Dawson, Laura A. ;
Bezjak, Andrea .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03) :688-695
[2]   3D Delivered Dose Assessment Using a 4DCT-Based Motion Model [J].
Cai, W. ;
Hurwitz, M. ;
Williams, C. ;
Dhou, S. ;
Berbeco, R. ;
Seco, J. ;
Cifter, F. ;
Myronakis, M. ;
Mishra, P. ;
Lewis, J. .
MEDICAL PHYSICS, 2015, 42 (06) :3669-3669
[3]   Evaluation of the motion of lung tumors during stereotactic body radiation therapy (SBRT) with four-dimensional computed tomography (4DCT) using real-time tumor-tracking radiotherapy system (RTRT) [J].
Harada, Keiichi ;
Katoh, Norio ;
Suzuki, Ryusuke ;
Ito, Yoichi M. ;
Shimizu, Shinichi ;
Onimaru, Rikiya ;
Inoue, Tetsuya ;
Miyamoto, Naoki ;
Shirato, Hiroki .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02) :305-311
[4]   Dosimetric comparison of lung stereotactic body radiotherapy treatment plans using averaged computed tomography and end-exhalation computed tomography images: Evaluation of the effect of different dose-calculation algorithms and prescription methods [J].
Mitsuyoshi, Takamasa ;
Nakamura, Mitsuhiro ;
Matsuo, Yukinori ;
Ueki, Nami ;
Nakamura, Akira ;
Iizuka, Yusuke ;
Mampuya, Wambaka Ange ;
Mizowaki, Takashi ;
Hiraoka, Masahiro .
MEDICAL DOSIMETRY, 2016, 41 (04) :305-309
[5]   Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy [J].
Oechsner, Markus ;
Odersky, Leonhard ;
Berndt, Johannes ;
Combs, Stephanie Elisabeth ;
Wilkens, Jan Jakob ;
Duma, Marciana Nona .
RADIATION ONCOLOGY, 2015, 10
[6]   Dosimetric comparison of treatment plans based on free breathing, maximum, and average intensity projection CTs for lung cancer SBRT [J].
Tian, Yuan ;
Wang, Zhiheng ;
Ge, Hong ;
Zhang, Tian ;
Cai, Jing ;
Kelsey, Christopher ;
Yoo, David ;
Yin, Fang-Fang .
MEDICAL PHYSICS, 2012, 39 (05) :2754-2760