Automatic Measurement of Thalamic Diameter in 2-D Fetal Ultrasound Brain Images Using Shape Prior Constrained Regularized Level Sets

被引:13
作者
Sridar, Pradeeba [1 ,2 ]
Kumar, Ashnil [2 ]
Li, Changyang [2 ]
Woo, Joyce [3 ]
Quinton, Ann [3 ,4 ,5 ]
Benzie, Ron [3 ]
Peek, Michael J. [3 ,4 ]
Feng, Dagan [2 ]
Kumar, R. Krishna [1 ]
Nanan, Ralph [3 ,4 ]
Kim, Jinman [2 ,3 ,4 ]
机构
[1] Indian Inst Technol, Dept Engn Design, Madras 600036, Tamil Nadu, India
[2] Univ Sydney, Inst Biomed Engn & Technol, Sydney, NSW 2006, Australia
[3] Univ Sydney, Sydney Med Sch Nepean, Kingswood, NSW 2747, Australia
[4] Univ Sydney, Charles Perkins Ctr, Sydney, NSW 2050, Australia
[5] Cent Queensland Univ, Sch Med & Appl Sci, Rockhampton, Qld 4702, Australia
关键词
Fetal brain; image segmentation; statistical shape model (SSM); thalamus; Ultrasound (US); SEGMENTATION;
D O I
10.1109/JBHI.2016.2582175
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
We derived an automated algorithm for accurately measuring the thalamic diameter from 2-D fetal ultrasound (US) brain images. The algorithm overcomes the inherent limitations of the US image modality: nonuniform density; missing boundaries; and strong speckle noise. We introduced a "guitar" structure that represents the negative space surrounding the thalamic regions. The guitar acts as a landmark for deriving the widest points of the thalamus even when its boundaries are not identifiable. We augmented a generalized level-set framework with a shape prior and constraints derived from statistical shape models of the guitars; this framework was used to segment US images and measure the thalamic diameter. Our segmentation method achieved a higher mean Dice similarity coefficient, Hausdorff distance, specificity, and reduced contour leakage when compared to other well-established methods. The automatic thalamic diameter measurement had an interobserver variability of -0.56 +/- 2.29 mm compared to manual measurement by an expert sonographer. Our method was capable of automatically estimating the thalamic diameter, with the measurement accuracy on par with clinical assessment. Our method can be used as part of computer-assisted screening tools that automatically measure the biometrics of the fetal thalamus; these biometrics are linked to neurodevelopmental outcomes.
引用
收藏
页码:1069 / 1078
页数:10
相关论文
共 36 条
  • [1] SEEDED REGION GROWING
    ADAMS, R
    BISCHOF, L
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1994, 16 (06) : 641 - 647
  • [2] On the estimation of the coefficient of variation for anisotropic diffusion speckle filtering
    Aja-Fernandez, Santiago
    Alberola-Lopez, Carlos
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2006, 15 (09) : 2694 - 2701
  • [3] American Institute of Ultrasound in Medicine, 2010, J Ultrasound Med, V29, P157
  • [4] Arrieta C, 2015, I S BIOMED IMAGING, P1568, DOI 10.1109/ISBI.2015.7164178
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] Bly S, 2005, J OBSTET GYNAECOL CA, V27, P572
  • [7] Brox T, 2005, THESIS
  • [8] Detection and measurement of fetal anatomies from ultrasound images using a constrained probabilistic boosting tree
    Carneiro, Gustavo
    Georaescu, Bogdan
    Good, Sara
    Comaniciu, Dorin
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (09) : 1342 - 1355
  • [9] Geodesic active contours
    Caselles, V
    Kimmel, R
    Sapiro, G
    [J]. INTERNATIONAL JOURNAL OF COMPUTER VISION, 1997, 22 (01) : 61 - 79
  • [10] Semi-Supervised Segmentation of Ultrasound Images Based on Patch Representation and Continuous Min Cut
    Ciurte, Anca
    Bresson, Xavier
    Cuisenaire, Olivier
    Houhou, Nawal
    Nedevschi, Sergiu
    Thiran, Jean-Philippe
    Cuadra, Meritxell Bach
    [J]. PLOS ONE, 2014, 9 (07):