Comparison of loop-mediated isothermal amplification, real-time PCR, and virus isolation for the detection of herpes simplex virus in genital lesions

被引:25
作者
Sugiyama, H
Yoshikawa, T [1 ]
Ihira, M
Enomoto, Y
Kawana, T
Asano, Y
机构
[1] Fujita Hlth Univ, Sch Med, Dept Pediat, Toyoake, Aichi 4701192, Japan
[2] Fujita Hlth Univ Coll, Dept Med Informat Technol, Toyoake, Aichi, Japan
[3] Teikyo Univ, Sch Med, Univ Hosp Mizonokuchi, Dept Obstet & Gynecol, Kanagawa, Japan
关键词
HSV; LAMP; real-time PCR;
D O I
10.1002/jmv.20309
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
This study compares herpes simplex virus (HSV) type-specific loop-mediated isothermal amplification (LAMP) with virus isolation and real-time PCR. Genital tract specimens were obtained from 25 patients with genital lesions; two swab samples were collected from the vulva and cervix of each patient, for a total of 50 specimens. Ar culturing, 10 of 50 (20%) samples were positive for HSV-1 and 12 of 50 (24%) samples were positive for HSV-2. None of the patients excreted both HSV-1 and HSV-2 virus. An original HSV type-specific LAMP assay (30 min reaction) was compared with virus isolation and HSV type-specific real-time PCR. Viral DNA was detected by LAMP in 9 of 10 HSV-1 isolated samples and 11 of 12 HSV-2 isolated samples. No viral DNA was detected in samples without virus isolation. Thus, if virus isolation was used as the standard method, the LAMP protocol was highly sensitive and specific. In comparing LAMP to real-time PCR, viral DNA was detected by the LAMP method in 9 of 12 HSV-1 DNA positive samples and 11 of 18 HSV-2 DNA positive samples. If real-time PCR was used as the standard method, then, sensitivity of the LAMP method (in particular, for HSV-2) was low. Taking this into consideration, the LAMP reaction was extended to 60 min. This led to an increase in sensitivity, resulting in an additional one and three samples testing positive for HSV-1 LAMP and HSV-2 LAMP, respectively, compared to the original LAMP protocol. Therefore, the sensitivity of the LAMP method increased to about 80%.
引用
收藏
页码:583 / 587
页数:5
相关论文
共 28 条
[1]   Rapid detection of herpes simplex virus DNA in genital ulcers by real-time PCR using SYBR green I dye as the detection signal [J].
Aldea, C ;
Alvarez, CP ;
Folgueira, L ;
Delgado, R ;
Otero, JR .
JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (03) :1060-1062
[2]   Monitoring herpesviruses DNA in three cases of acute retinal necrosis by real-time PCR [J].
Asano, S ;
Yoshikawa, T ;
Kimura, H ;
Enomoto, Y ;
Ohashi, M ;
Terasaki, H ;
Nishiyama, Y .
JOURNAL OF CLINICAL VIROLOGY, 2004, 29 (03) :206-209
[3]   EXTENDED DURATION OF HERPES-SIMPLEX VIRUS-DNA IN GENITAL LESIONS DETECTED BY THE POLYMERASE CHAIN-REACTION [J].
CONE, RW ;
HOBSON, AC ;
PALMER, J ;
REMINGTON, M ;
COREY, L .
JOURNAL OF INFECTIOUS DISEASES, 1991, 164 (04) :757-760
[4]   FREQUENT DETECTION OF GENITAL HERPES-SIMPLEX VIRUS-DNA BY POLYMERASE CHAIN-REACTION AMONG PREGNANT-WOMEN [J].
CONE, RW ;
HOBSON, AC ;
BROWN, Z ;
ASHLEY, R ;
BERRY, S ;
WINTER, C ;
COREY, L .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 272 (10) :792-796
[5]  
ENOMOTO Y, IN PRESS J CLIN MICR
[6]   Use of loop-mediated isothermal amplification of the IS900 sequence for rapid detection of cultured Mycobacterium avium subsp. paratuberculosis [J].
Enosawa, M ;
Kageyama, S ;
Sawai, K ;
Watanabe, K ;
Notomi, T ;
Onoe, S ;
Mori, Y ;
Yokomizo, Y .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (09) :4359-4365
[7]   COMPARISON OF SHELL VIALS AND CONVENTIONAL TUBES SEEDED WITH RHABDOMYOSARCOMA AND MRC-5 CELLS FOR THE RAPID DETECTION OF HERPES-SIMPLEX VIRUS [J].
ESPY, MJ ;
WOLD, AD ;
JESPERSEN, DJ ;
JONES, MF ;
SMITH, TF .
JOURNAL OF CLINICAL MICROBIOLOGY, 1991, 29 (12) :2701-2703
[8]   Diagnosis of herpes simplex virus infections in the clinical laboratory by LightCycler PCR [J].
Espy, MJ ;
Uhl, JR ;
Mitchell, PS ;
Thorvilson, JN ;
Svien, KA ;
Wold, AD ;
Smith, TF .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (02) :795-799
[9]   Rapid diagnosis of human herpesvirus 6 infection by a novel DNA amplification method, loop-mediated isothermal amplification [J].
Ihira, M ;
Yoshikawa, T ;
Enomoto, Y ;
Akimoto, S ;
Ohashi, M ;
Suga, S ;
Nishimura, N ;
Ozaki, T ;
Nishiyama, Y ;
Notomi, T ;
Ohta, Y ;
Asano, Y .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (01) :140-145
[10]   Loop-mediated isothermal amplification for direct detection of Mycobacterium tuberculosis complex, M-avium, and M-intracellulare in sputum samples [J].
Iwamoto, T ;
Sonobe, T ;
Hayashi, K .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (06) :2616-2622