Simplified low-copy-number DNA analysis by Post-PCR purification

被引:67
作者
Smith, Pamela J.
Ballantyne, Jack
机构
[1] Texas Dept Publ Safety, Crime Lab Serv, Corpus Christi, TX 78416 USA
[2] Univ Cent Florida, Grad Program Chem, Orlando, FL 32816 USA
[3] Univ Cent Florida, Dept Chem, Orlando, FL 32816 USA
[4] Natl Ctr Forens Sci, Orlando, FL 32816 USA
关键词
forensic science; DNA typing; polymerase chain reaction; purification; low copy number; identifiler; MinElute; microcon; montage PCR; ExoSAP-IT;
D O I
10.1111/j.1556-4029.2007.00470.x
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Frequently, evidentiary items contain an insufficient quantity of DNA to obtain complete or even partial DNA profiles using standard forensic gentotyping techniques. Such low-copy-number (LCN) samples are usually subjected to increased amplification cylces to obtain genetic data. In this study, a 28-cycle polymerase chain reaction (PCR) was used to evaluate various methods of post-PCR purification for their effects on the sensitivity of fluorophore-based allelic detection subsequent to capillary electrophoretic separation. The amplified product was purified using filtration, silica gel membrane, and enzyme mediated hydrolysis purification techniques and evaluated for their effect on fluorescent allelic signal intensity. A purification method was selected and its effect on fluorescent allelic signal intensity was compared with that of the unpurified PCR product. A method of post-PCR purification is described which increases the sensitivity of standard 28-cycle PCR such that profiles from LCN DNA templates (< 100 pg DNA) can be obtained. Full DNA profiles were consistently obtained with as little as 20 pg template DNA without increased cycle number. In mock case type samples with dermal ridge fingerprints, genetic profiles were obtained by amplification with 28 cycles followed by post-PCR purification whereas no profiles were obtained without purification of the PCR product. Allele dropout, increased stutter, and sporadic contamination typical of LCN analysis were observed; however, no contamination was observed in negative amplification controls. Post-PCR purification of the PCR product can increase the sensitivity of capillary electrophoresis to such an extent that DNA profiles can be obtained from < 100 pg of DNA using 28-cycle amplification.
引用
收藏
页码:820 / 829
页数:10
相关论文
共 22 条
  • [11] NIST mixed stain study 3: DNA quantitation accuracy and its influence on short tandem repeat multiplex signal intensity
    Kline, MC
    Duewer, DL
    Redman, JW
    Butler, JM
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (10) : 2463 - 2469
  • [12] Efficacy and limits of genotyping low copy number DNA samples by multiplex PCR of STR loci
    Kloosterman, AD
    Kersbergen, P
    [J]. PROGRESS IN FORENSIC GENETICS 9, 2003, 1239 : 795 - 798
  • [13] Krenke BE, 2002, J FORENSIC SCI, V47, P773
  • [14] Leclair B, 2003, J FORENSIC SCI, V48, P1001
  • [15] Levedakou EN, 2002, J FORENSIC SCI, V47, P757
  • [16] Mezei Louis M., 1994, P13
  • [17] Archived or directly swabbed latent fingerprints as a DNA source for STR typing
    Schulz, MM
    Reichert, W
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2002, 127 (1-2) : 128 - 130
  • [18] Shewale JG, 2003, J FORENSIC SCI, V48, P127
  • [19] Reliable genotyping of samples with very low DNA quantities using PCR
    Taberlet, P
    Griffin, S
    Goossens, B
    Questiau, S
    Manceau, V
    Escaravage, N
    Waits, LP
    Bouvet, J
    [J]. NUCLEIC ACIDS RESEARCH, 1996, 24 (16) : 3189 - 3194
  • [20] DNA fingerprints from fingerprints
    vanOorschot, RAH