Hybrid control approach for low-voltage ride-through capability in doubly-fed induction generator-based wind turbines

被引:4
作者
Dosoglu, M. Kenan [1 ]
机构
[1] Duzce Univ, Fac Engn, Elect Elect Engn Dept, TR-81620 Konuralp, Duzce, Turkey
关键词
DFIG; LVRT capability; Hybrid control approach; Stator-rotor emf model; FAULT-RIDE; STRATEGY;
D O I
10.1016/j.compeleceng.2021.106972
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Grid-connected doubly-fed induction generator (DFIG)-based wind turbines are very sensitive to voltage dip problems that occur in grid side. Therefore, different low-voltage ride-through (LVRT) capability methods are used to decrease the voltage dip problems. In this study, it is aimed to present a hybrid control approach to provide LVRT capability in DFIG. Moreover, it is aimed to develop electromotive-force (emf) models in a stator-rotor circuit. The rotor emf model is used to compensate for the voltage dip and reduce the oscillations while using the stator emf model to ensure the ease of calculation and accuracy of the simulation study. In the results, this paper is reporting that the hybrid control approach proposed in this study has given yield effective and better results in comparison with those of the conventional DFIG model.
引用
收藏
页数:12
相关论文
共 23 条
[1]  
[Anonymous], 2002, Analysis of electric machinery and drive systems
[2]   A robust power control strategy to enhance LVRT capability of grid-connected DFIG-based wind energy systems [J].
Ardjoun, Sid Ahmed El Mehdi ;
Denai, Mouloud ;
Abid, Mohamed .
WIND ENERGY, 2019, 22 (06) :834-847
[3]   Specification of rotor side voltage source inverter of a doubly-fed induction generator for achieving ride-through capability [J].
Chondrogionnis, S. ;
Barnes, M. .
IET RENEWABLE POWER GENERATION, 2008, 2 (03) :139-150
[4]   Unified DC-Link Current Control for Low-Voltage Ride-Through in Current-Source-Converter-Based Wind Energy Conversion Systems [J].
Dai, Jingya ;
Xu, Dewei ;
Wu, Bin ;
Zargari, Navid R. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (01) :288-297
[5]   Impact of Grid Impedance on LVRT Performance of DFIG System With Rotor Crowbar Technology [J].
Din, Zakiud ;
Zhang, Jianzhong ;
Zhu, Yaodong ;
Xu, Zheng ;
El-Naggar, Ahmed .
IEEE ACCESS, 2019, 7 :127999-128008
[6]   Analyzing low voltage ride through capability of doubly fed induction generator based wind turbine [J].
Gebru, Fsaha Mebrahtu ;
Khan, Baseem ;
Alhelou, Hassan Haes .
COMPUTERS & ELECTRICAL ENGINEERING, 2020, 86
[7]   An Improved Low-Voltage Ride-Through Control Strategy of Doubly Fed Induction Generator During Grid Faults [J].
Hu, Sheng ;
Lin, Xinchun ;
Kang, Yong ;
Zou, Xudong .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (12) :3653-3665
[8]   A Highly Effective Fault-Ride-Through Strategy for a Wind Energy Conversion System With a Doubly Fed Induction Generator [J].
Jabbour, Nikolaos ;
Tsioumas, Evangelos ;
Mademlis, Christos ;
Solomin, Evgeny .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (08) :8154-8164
[9]   Real-time simulator based hybrid controller of DFIG-WES during grid faults design and analysis [J].
Jaladi, Kiran Kumar ;
Sandhu, Kanwarjit Singh .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 116
[10]   A new hybrid control scheme for minimizing torque and flux ripple for DFIG-based WES under random change in wind speed [J].
Jaladi, Kiran Kumar ;
Sandhu, Kanwarjit Singh .
INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2019, 29 (04)