Optical Coherence Tomography Assessment of In Vivo Vascular Response After Implantation of Overlapping Bare-Metal and Drug-Eluting Stents

被引:141
作者
Guagliumi, Giulio [1 ]
Musumeci, Giuseppe [1 ]
Sirbu, Vasile [1 ]
Bezerra, Hiram G. [2 ]
Suzuki, Nobuaki [2 ]
Fiocca, Luigi [1 ]
Matiashvili, Aleksandre [1 ]
Lortkipanidze, Nikoloz [1 ]
Trivisonno, Antonio [1 ]
Valsecchi, Orazio [1 ]
Biondi-Zoccai, Giuseppe [3 ]
Costa, Marco A. [2 ]
机构
[1] Osped Riuniti Bergamo, Div Cardiol, Cardiovasc Dept, I-24121 Bergamo, Italy
[2] Case Western Reserve Univ, Univ Hosp Case Med Ctr, Harrington McLaughlin Heart & Vasc Inst, Cleveland, OH 44106 USA
[3] Univ Turin, Div Cardiol, Turin, Italy
关键词
coronary artery disease; optical coherence tomography; percutaneous transluminal coronary angioplasty; stent; INTRAVASCULAR ULTRASOUND; THROMBOSIS; COVERAGE;
D O I
10.1016/j.jcin.2010.02.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We designed a randomized trial exploiting optical coherence tomography (OCT) to assess coverage and apposition of overlapping bare-metal stents (BMS) and drug-eluting stents (DES) in human coronary arteries. Background Overlapping DES impair healing in animals. Optical coherence tomography allows accurate in vivo assessment of stent strut coverage and apposition. Methods Seventy-seven patients with long coronary stenoses were randomized to overlapping sirolimus-eluting stents (SES), paclitaxel-eluting stents (PES), zotarolimus-eluting stents (ZES), or BMS. The primary goal of the study was to determine the rate of uncovered/malapposed strut; in overlap versus nonoverlap segments, according to stent type, at 6-month follow-up with OCT. Results A total of 53,047 struts were analyzed. The rate of uncovered/malapposed struts was 1.5 +/- 3.4% and 0.6 +/- 2.7% in overlap versus nonoverlap BMS (p = NS), respectively, and 4.3 +/- 11% and 3.6 +/- 8% in overlap versus nonoverlap DES (p = NS), respectively. There were no differences in the rates of uncovered/malapposed struts between overlapping BMS and DES, likely due to law frequency of uncovered/malapposed struts in ZES (0.1 +/- 0.4%), which offset the higher rates observed in SES (6.7 +/- 9.6%) and PES (6.7 +/- 16.5%, p < 0.05). Overlap segments showed greater neointimal volume obstruction versus nonoverlap segments in all DES (p < 0.05 for all DES types). Strut-level neointimal thickness at overlap and nonoverlap segments were lowest in SES (0.16 +/- 0.1 mm and 0.12 +/- 0.1 mm, respectively) compared with PES (0.27 +/- 0.1 mm and 0.20 +/- 0.1 mm, respectively), ZES (0.40 +/- 0.16 mm and 0.33 +/- 0.13 mm, respectively), and BMS (0.55 +/- 0.31 mm and 0.53 +/- 0.25 mm, respectively, p < 0.05). Conclusions As assessed by OCT the impact of DES on vascular healing was similar at overlapping and nonoverlapping sites. However, strut malapposition, coverage pattern, and neointimal hyperplasia differ significantly according to DES type. (Optical Coherence Tomography for Drug Eluting Stent Safety [ODESSA]; NCT00693030) (J Am Coll Cardiol Intv 2010;3:531-9) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:531 / 539
页数:9
相关论文
共 50 条
  • [31] The effects of drug-eluting stent polymer on measurement of strut thickness by optical coherence tomography: In-vitro comparison with bare-metal stent
    Mizuno, Masayuki
    Takano, Masamichi
    Mizuno, Kyoichi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 145 (01) : 48 - 49
  • [32] Stent Thrombosis After Percutaneous Coronary Intervention From Bare-Metal to the Last Generation of Drug-Eluting Stents
    Polimeni, Alberto
    Sorrentino, Sabato
    Spaccarotella, Carmen
    Mongiardo, Annalisa
    Sabatino, Jolanda
    De Rosa, Salvatore
    Gori, Tommaso
    Indolfi, Ciro
    CARDIOLOGY CLINICS, 2020, 38 (04) : 639 - 647
  • [33] Pathology of Chronic Total Occlusion in Bare-Metal Versus Drug-Eluting Stents
    Mori, Hiroyoshi
    Lutter, Christoph
    Yahagi, Kazuyuki
    Harari, Emanuel
    Kutys, Robert
    Fowler, David R.
    Ladich, Elena
    Joner, Michael
    Virmani, Renu
    Finn, Aloke V.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (04) : 367 - 378
  • [34] Drug-eluting versus bare-metal stents for saphenous vein graft lesions
    Conte, Sean M.
    Florisson, Daniel S.
    De Bono, Joshua A.
    Vale, Peter R.
    INTERNAL MEDICINE JOURNAL, 2019, 49 (12) : 1534 - 1537
  • [35] Differential healing response attributed to culprit lesions of patients with acute coronary syndromes and stable coronary artery after implantation of drug-eluting stents: An optical coherence tomography study
    Raeber, Lorenz
    Zanchin, Thomas
    Baumgartner, Sandro
    Taniwaki, Masanori
    Kalesan, Bindu
    Moschovitis, Aris
    Garcia-Garcia, Hector M.
    Justiz, Joern
    Pilgrim, Thomas
    Wenaweser, Peter
    Meier, Bernhard
    Jueni, Peter
    Windecker, Stephan
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 173 (02) : 259 - 267
  • [36] A glimpse into first generation drug-eluting and bare metal stents ten years later with optical coherence tomography analysis
    Buccheri, Dario
    Cortese, Bernardo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 212 : 129 - 130
  • [37] Drug-eluting stents versus bare-metal stents in acute myocardial infarction with cardiogenic shock
    Ledwoch, Jakob
    Fuernau, Georg
    Desch, Steffen
    Eitel, Ingo
    Jung, Christian
    de Waha, Suzanne
    Poess, Janine
    Schneider, Steffen
    Schuler, Gerhard
    Werdan, Karl
    Zeymer, Uwe
    Thiele, Holger
    HEART, 2017, 103 (15) : 1177 - 1184
  • [38] Effect of Length and Diameter of Drug-Eluting Stents Versus Bare-Metal Stents on Late Outcomes
    Applegate, Robert J.
    Sacrinty, Matthew T.
    Kutcher, Michael A.
    Santos, Renato M.
    Gandhi, Sanjay K.
    Little, William C.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (01) : 35 - 42
  • [39] Drug-eluting or bare-metal stents in interventional cardiology. Theory and Practice
    Er, Fikret
    Erdmann, Erland
    MEDIZINISCHE KLINIK, 2007, 102 (01) : 30 - 32
  • [40] Optical coherence tomography analysis for restenosis of drug-eluting stents
    Yamamoto, Masanori
    Takano, Masamichi
    Murakami, Daisuke
    Inami, Toru
    Kimata, Nakatune
    Inami, Shigenobu
    Okamatsu, Kentaro
    Ohba, Takayoshi
    Seino, Yoshihiko
    Mizuno, Kyoichi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 146 (01) : 100 - 103