Optical Coherence Tomography Assessment of In Vivo Vascular Response After Implantation of Overlapping Bare-Metal and Drug-Eluting Stents

被引:141
|
作者
Guagliumi, Giulio [1 ]
Musumeci, Giuseppe [1 ]
Sirbu, Vasile [1 ]
Bezerra, Hiram G. [2 ]
Suzuki, Nobuaki [2 ]
Fiocca, Luigi [1 ]
Matiashvili, Aleksandre [1 ]
Lortkipanidze, Nikoloz [1 ]
Trivisonno, Antonio [1 ]
Valsecchi, Orazio [1 ]
Biondi-Zoccai, Giuseppe [3 ]
Costa, Marco A. [2 ]
机构
[1] Osped Riuniti Bergamo, Div Cardiol, Cardiovasc Dept, I-24121 Bergamo, Italy
[2] Case Western Reserve Univ, Univ Hosp Case Med Ctr, Harrington McLaughlin Heart & Vasc Inst, Cleveland, OH 44106 USA
[3] Univ Turin, Div Cardiol, Turin, Italy
关键词
coronary artery disease; optical coherence tomography; percutaneous transluminal coronary angioplasty; stent; INTRAVASCULAR ULTRASOUND; THROMBOSIS; COVERAGE;
D O I
10.1016/j.jcin.2010.02.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We designed a randomized trial exploiting optical coherence tomography (OCT) to assess coverage and apposition of overlapping bare-metal stents (BMS) and drug-eluting stents (DES) in human coronary arteries. Background Overlapping DES impair healing in animals. Optical coherence tomography allows accurate in vivo assessment of stent strut coverage and apposition. Methods Seventy-seven patients with long coronary stenoses were randomized to overlapping sirolimus-eluting stents (SES), paclitaxel-eluting stents (PES), zotarolimus-eluting stents (ZES), or BMS. The primary goal of the study was to determine the rate of uncovered/malapposed strut; in overlap versus nonoverlap segments, according to stent type, at 6-month follow-up with OCT. Results A total of 53,047 struts were analyzed. The rate of uncovered/malapposed struts was 1.5 +/- 3.4% and 0.6 +/- 2.7% in overlap versus nonoverlap BMS (p = NS), respectively, and 4.3 +/- 11% and 3.6 +/- 8% in overlap versus nonoverlap DES (p = NS), respectively. There were no differences in the rates of uncovered/malapposed struts between overlapping BMS and DES, likely due to law frequency of uncovered/malapposed struts in ZES (0.1 +/- 0.4%), which offset the higher rates observed in SES (6.7 +/- 9.6%) and PES (6.7 +/- 16.5%, p < 0.05). Overlap segments showed greater neointimal volume obstruction versus nonoverlap segments in all DES (p < 0.05 for all DES types). Strut-level neointimal thickness at overlap and nonoverlap segments were lowest in SES (0.16 +/- 0.1 mm and 0.12 +/- 0.1 mm, respectively) compared with PES (0.27 +/- 0.1 mm and 0.20 +/- 0.1 mm, respectively), ZES (0.40 +/- 0.16 mm and 0.33 +/- 0.13 mm, respectively), and BMS (0.55 +/- 0.31 mm and 0.53 +/- 0.25 mm, respectively, p < 0.05). Conclusions As assessed by OCT the impact of DES on vascular healing was similar at overlapping and nonoverlapping sites. However, strut malapposition, coverage pattern, and neointimal hyperplasia differ significantly according to DES type. (Optical Coherence Tomography for Drug Eluting Stent Safety [ODESSA]; NCT00693030) (J Am Coll Cardiol Intv 2010;3:531-9) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:531 / 539
页数:9
相关论文
共 50 条
  • [1] Assessment by Optical Coherence Tomography of Stent Struts Across Side Branch - Comparison of Bare-Metal Stents and Drug-Eluting Stents
    Liu, Yong
    Imanishi, Toshio
    Kubo, Takashi
    Tanaka, Atsushi
    Kitabata, Hironori
    Tanimoto, Takashi
    Ino, Yasushi
    Ikejima, Hideyuki
    Tsujioka, Hiroto
    Komukai, Kenichi
    Ishibashi, Kohei
    Kashiwagi, Manabu
    Ozaki, Yuichi
    Hirata, Kumiko
    Mizukoshi, Masato
    Akasaka, Takashi
    CIRCULATION JOURNAL, 2011, 75 (01) : 106 - 112
  • [2] Qualitative and Quantitative Assessment of Stent Restenosis by Optical Coherence Tomography - Comparison Between Drug-Eluting and Bare-Metal Stents
    Nagoshi, Ryoji
    Shinke, Toshiro
    Otake, Hiromasa
    Shite, Junya
    Matsumoto, Daisuke
    Kawamori, Hiroyuki
    Nakagawa, Masayuki
    Kozuki, Amane
    Hariki, Hirotoshi
    Inoue, Takumi
    Ohsue, Tsuyoshi
    Taniguchi, Yu
    Iwasaki, Masamichi
    Nishio, Ryo
    Hiranuma, Noritoshi
    Konishi, Akihide
    Kinutani, Hiroto
    Miyoshi, Naoki
    Takaya, Tomofumi
    Yamada, Shinichiro
    Yasaka, Yoshinori
    Hayashi, Takatoshi
    Yokoyama, Mitsuhiro
    Kato, Hiroki
    Kadotani, Makoto
    Ohnishi, Yoshio
    Hirata, Ken-ichi
    CIRCULATION JOURNAL, 2013, 77 (03) : 652 - 660
  • [3] Are drug-eluting stents safer than bare-metal stents?
    Jensen, Lisette Okkels
    Christiansen, Evald Hoj
    LANCET, 2019, 393 (10190) : 2472 - 2474
  • [4] Drug-Eluting Stents Versus Bare-Metal Stents for Treatment of Bare-Metal In-Stent Restenosis
    Singh, Inder M.
    Filby, Steven J.
    El Sakr, Fredy
    Gorodeski, Eiran Z.
    Lincoff, A. Michael
    Ellis, Stephen G.
    Shishehbor, Mehdi H.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (02) : 257 - 262
  • [5] Optical Coherence Tomography and Histopathology Assessment After Implantation of First- and Second-Generation Drug-Eluting Stents in a Porcine Coronary Model
    Hiranuma, Noritoshi
    Shinke, Toshiro
    Nakazawa, Gaku
    Otake, Hiromasa
    Matsumoto, Daisuke
    Ijichi, Takeshi
    Kawamori, Hiroyuki
    Nagoshi, Ryoji
    Osue, Tsuyoshi
    Shite, Junya
    Hirata, Ken-ichi
    CIRCULATION JOURNAL, 2014, 78 (11) : 2665 - 2673
  • [6] Assessment of vascular response after drug-eluting stents implantation in patients with diabetes mellitus: an optical coherence tomography sub-study of the J-DESsERT
    Kubo, Takashi
    Akasaka, Takashi
    Tanimoto, Takashi
    Takano, Masamichi
    Seino, Yoshitane
    Nasu, Kenya
    Itoh, Tomonori
    Mizuno, Kyoichi
    Okura, Hiroyuki
    Shinke, Toshiro
    Kotani, Jun-ichi
    Ito, Shigenori
    Yokoi, Hiroyoshi
    Muramatsu, Toshiya
    Nakamura, Masato
    Nanto, Shinsuke
    HEART AND VESSELS, 2016, 31 (04) : 465 - 473
  • [7] Drug-Eluting or Bare-Metal Stents for Coronary Artery Disease
    Bonaa, K. H.
    Mannsverk, J.
    Wiseth, R.
    Aaberge, L.
    Myreng, Y.
    Nygard, O.
    Nilsen, D. W.
    Klow, N. -E.
    Uchto, M.
    Trovik, T.
    Bendz, B.
    Stavnes, S.
    Bjornerheim, R.
    Larsen, A. -I.
    Slette, M.
    Steigen, T.
    Jakobsen, O. J.
    Bleie, O.
    Fossum, E.
    Hanssen, T. A.
    Dahl-Eriksen, O.
    Njolstad, I.
    Rasmussen, K.
    Wilsgaard, T.
    Nordrehaug, J. E.
    NEW ENGLAND JOURNAL OF MEDICINE, 2016, 375 (13) : 1242 - 1252
  • [8] Comparison Between Bare-Metal Stents, First-Generation Drug-Eluting Stents, and Bioresorbable Vascular Scaffolds
    Ng, Andrew Kei-Yan
    Ng, Pauline Yeung
    Siu, Chung-Wah
    Jim, Man-Hong
    JOURNAL OF INVASIVE CARDIOLOGY, 2021, 33 (06) : E467 - E473
  • [9] Incidence of diffuse and focal chronic stent recoil after implantation of current generation bare-metal and drug-eluting stents
    Koo, Bon-Kwon
    Waseda, Katsuhisa
    Ako, Junya
    Hasegawa, Takao
    Shimohama, Takao
    Nakatani, Daisaku
    Otake, Hiromasa
    Yamasaki, Masao
    Sakurai, Ryota
    Tsujino, Ichizo
    Honda, Yasuhiro
    Fitzgerald, Peter J.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 144 (01) : 132 - 134
  • [10] Identification of independent risk factors for restenosis following bare-metal stent implantation: Role of bare-metal stents in the era of drug-eluting stents
    Park, Chang-Bum
    Park, Hoon-Ki
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 6 (03) : 840 - 846