Clinical application of a model-based cardiac stroke volume estimation method

被引:1
作者
Smith, Rachel [1 ]
Balmer, Joel [1 ]
Pretty, Christopher G. [1 ]
Shaw, Geoffrey M. [2 ]
Chase, J. Geoffrey [1 ]
机构
[1] Univ Canterbury, Dept Mech Engn, Canterbury, New Zealand
[2] Christchurch Hosp Intens Care Unit, Christchurch, New Zealand
来源
IFAC PAPERSONLINE | 2020年 / 53卷 / 02期
基金
欧盟地平线“2020”;
关键词
Pulse contour analysis; Pressure contour analysis; Windkessel model; Stroke volume; Cardiac output; Hemodynamic monitoring; Intensive care; PRESSURE; OUTPUT; PULSE; ANESTHESIA; ACCURACY; SHOCK;
D O I
10.1016/j.ifacol.2020.12.435
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A system is needed for monitoring stroke volume (SV) and cardiac output (CO) in unstable patients which is non-additionally invasive, reproducible and reliable in a variety of physiological states. This study evaluates SV estimation accuracy of a non-additionally invasive pulse contour analysis method implemented using a 3-element Windkessel model. The model lumps the properties of the arterial system into 3 parameters: characteristic impedance of the proximal aorta (Z), and resistance (R) and compliance (C) of the systemic arteries. Parameter products ZC and RC are dynamically identified from measured femoral arterial pressure waveforms, and Z is a static parameter obtained by calibration. The accuracy of the model is evaluated for a cohort of 9 liver transplant patients, using thermodilution as a reference method. Data were obtained from Vital Data Bank (VitalDB). The study thus provides independent assessment of a pulse contour analysis, proven in animal studies, in an uncontrolled clinical environment. The model tracked trends in SV well over the course of the surgery. However, the 95% range for percentage error was -88% to +53%, outside acceptable limits of +/- 45%. Main areas contributing to error for the model include the changing extent of reflected waves in the arterial system, dynamic response characteristics of fluid-filled pressure catheters, and the assumption of fixed Z parameter. Further investigation is needed to consider the contribution of these factors to SV estimation error by the model. Copyright (C) 2020 The Authors.
引用
收藏
页码:16137 / 16142
页数:6
相关论文
共 50 条
  • [41] Model-based inference for biomass estimation in a LiDAR sample survey in Hedmark County, Norway
    Stahl, Goran
    Holm, Soren
    Gregoire, Timothy G.
    Gobakken, Terje
    Naesset, Erik
    Nelson, Ross
    CANADIAN JOURNAL OF FOREST RESEARCH-REVUE CANADIENNE DE RECHERCHE FORESTIERE, 2011, 41 (01): : 96 - 107
  • [42] Prediction model-based kernel density estimation when group membership is subject to missing
    He, Hua
    Wang, Wenjuan
    Tang, Wan
    ASTA-ADVANCES IN STATISTICAL ANALYSIS, 2017, 101 (03) : 267 - 288
  • [43] Biplanar Videoradiography Dataset for Model-based Pose Estimation Development and New User Training
    Welte, Lauren
    Dickinson, Andrew
    Arndt, Anton
    Rainbow, Michael J.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (183):
  • [44] Differential Model-Based Parameter Estimation of IPMSMs From Multi-State Measurements
    Cheng, Hongfu
    Deshpande, Uday
    Kar, Narayan C.
    IEEE TRANSACTIONS ON MAGNETICS, 2024, 60 (09)
  • [45] Clinical Application of an Automatic Slice-Alignment Method for Cardiac MR Imaging
    Yokoyama, Kenichi
    Ishimura, Rieko
    Kariyasu, Toshiya
    Imai, Masamichi
    Nitatori, Toshiaki
    Kuhara, Shigehide
    Nitta, Shuhei
    Takeguchi, Tomoyuki
    Matsumoto, Nobuyuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2014, 13 (04) : 293 - 298
  • [46] Kidney Stone Volume Estimation from Computerized Tomography Images Using a Model Based Method of Correcting for the Point Spread Function
    Duan, Xinhui
    Wang, Jia
    Qu, Mingliang
    Leng, Shuai
    Liu, Yu
    Krambeck, Amy
    McCollough, Cynthia
    JOURNAL OF UROLOGY, 2012, 188 (03) : 989 - 995
  • [47] Novel blood pressure and pulse pressure estimation based on pulse transit time and stroke volume approximation
    Joonnyong Lee
    JangJay Sohn
    Jonghyun Park
    SeungMan Yang
    Saram Lee
    Hee Chan Kim
    BioMedical Engineering OnLine, 17
  • [48] Novel blood pressure and pulse pressure estimation based on pulse transit time and stroke volume approximation
    Lee, Joonnyong
    Sohn, JangJay
    Park, Jonghyun
    Yang, SeungMan
    Lee, Saram
    Kim, Hee Chan
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [49] Estimation of Stroke Volume and Aortic Valve Area in Patients With Aortic Stenosis: A Comparison of Doppler-Echocardiography and Cardiac Magnetic Resonance
    Capoulade, Romain
    Le Ven, Florent
    Garcia, Julio
    Tastet, Lionel
    Dahou, Abdellaziz
    Dumesnil, Jean G.
    Arsenault, Marie
    Bedard, Elisabeth
    Larose, Eric
    Pibarot, Philippe
    CIRCULATION, 2014, 130
  • [50] Model-Based Estimation of Flow Characteristics Using an Ionic Polymer-Metal Composite Beam
    Chen, Xuefei
    Zhu, Guoming
    Yang, Xiaojian
    Hung, David L. S.
    Tan, Xiaobo
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2013, 18 (03) : 932 - 943