Effect of contamination by oxygen at trace level in miniature flame hydride atomizers

被引:13
作者
D'Ulivo, A
Dedina, J
Lampugnani, L
机构
[1] CNR, Lab Chim Analit Strumentale, Ist & Proc Chimicofis, Area Ric Pisa, I-56124 Pisa, Italy
[2] Acad Sci Czech Republ, Inst Analyt Chem, Lab Trace Element Anal, Prague 14220 4, Czech Republic
关键词
D O I
10.1039/b412571a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new type of atomization interference, caused by traces of oxygen in gases supplied to the atomizer, has been identified in three different types of miniature flame hydride atomizer for atomic fluorescence spectrometry, namely argon - hydrogen diffusion flame (MDF), flame-in-gas shield (FIGS) and double flame (DF), which is a combination of MDF and FIGS. The interference magnitude is dramatically dependent on the analyte element (Se much less than As less than or equal to Sb), on the type of atomizer and on the atomizer operating parameters. The thresholds of interference could be as low as a few parts per million (mul l(-1)) of oxygen in the carrier gas. The main sources of interfering oxygen are, in order, the oxygen stripped out from sample and reagent solutions in the hydride generation step followed by the oxygen diffusing inside the gas circuit of hydride generation apparatus.
引用
收藏
页码:40 / 45
页数:6
相关论文
共 13 条
[1]   THE DETERMINATION OF SELENIUM WITH HYDRIDE GENERATION AAS .4. APPLICATION TO COAL ANALYSIS [J].
AGTERDENBOS, J ;
VANELTEREN, JT ;
BAX, D ;
TERHEEGE, JP .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (04) :303-316
[2]   Cold vapour atomic fluorescence studies on the behaviour of mercury(II) and mercury(II)-thiol complexes. An alternative route for characterization of -SH binding groups [J].
Bramanti, E ;
D'Ulivo, A ;
Lampugnani, L ;
Raspi, G ;
Zamboni, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (02) :179-185
[3]   Masking agents in the determination of selenium by hydride generation technique [J].
D'Ulivo, A ;
Gianfranceschi, L ;
Lampugnani, L ;
Zamboni, R .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (12) :2081-2094
[4]   The relation of double peaks, observed in quartz hydride atomizers, to the fate of free analyte atoms in the determination of arsenic and selenium by atomic absorption spectrometry [J].
D'Ulivo, A ;
Dedina, J .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (12) :2069-2079
[5]   Mechanism of selenium hydride atomization, fate of free atoms and temperature distribution in an argon shielded, highly fuel-rich, hydrogen-oxygen diffusion micro-flame studied by atomic absorption spectrometry [J].
D'Ulivo, A ;
Dedina, J ;
Lampugnani, L ;
Matousek, T .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (03) :253-257
[6]   Improving the analytical performance of hydride generation non-dispersive atomic fluorescence spectrometry. Combined effect of additives and optical filters [J].
D'Ulivo, A ;
Bramanti, E ;
Lampugnani, L ;
Zamboni, R .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (10) :1893-1907
[7]   QUARTZ TUBE ATOMIZERS FOR HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY - MECHANISM FOR ATOMIZATION OF ARSINE - INVITED LECTURE [J].
DEDINA, J ;
WELZ, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) :307-314
[8]   Argon shielded, highly fuel-rich, hydrogen-oxygen diffusion microflame - a new hydride atomizer [J].
Dedina, J ;
D'Ulivo, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (12) :1737-1746
[9]   Selenium hydride atomization, fate of free atoms and spectroscopic temperature in miniature diffusion flame atomizer studied by atomic absorption spectrometry [J].
Dedina, J ;
D'Ulivo, A ;
Lampugnani, L ;
Matousek, T ;
Zamboni, R .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (13) :1777-1790
[10]   Antimony speciation at ultra trace levels using hydride generation atomic fluorescence spectrometry and 8-hydroxyquinoline as an efficient masking agent [J].
Deng, TL ;
Chen, YW ;
Belzile, N .
ANALYTICA CHIMICA ACTA, 2001, 432 (02) :293-302