Impact of apheresis automation on procedure quality and predictability of CD34+ cell yield

被引:3
|
作者
Besson, Nelly [1 ]
Bruun, Mie Topholm [2 ]
Larsen, Thomas Stauffer [3 ]
Nielsen, Christian [2 ]
机构
[1] Med Affairs Dept Terumo BCT, Zaventem, Belgium
[2] Odense Univ Hosp, Dept Clin Immunol, JP Winslows Vej 4, DK-5000 Odense C, Denmark
[3] Odense Univ Hosp, Dept Haematol, Odense, Denmark
关键词
CD34(+)cells; hematopoietic stem cells; spectra optia; PERIPHERAL-BLOOD; PROGENITOR CELLS; COLLECTION; EFFICIENCY; TRANSPLANTATION; LEUKAPHERESIS; MOBILIZATION; VALIDATION; PREDICTION; COUNTS;
D O I
10.1002/jca.21625
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Success of peripheral blood stem cell (PBSC) collections depends on patient biological parameters and stable apheresis device performance. We investigated product quality and factors influencing main apheresis procedure outcomes including CD34(+) collection efficiency (CE), product volume or platelet CE. We also assessed different CD34(+) cell yield prediction algorithms. Autologous PBSC collections by Spectra Optia from myeloma and lymphoma patients were analyzed. Complete blood count (CBC) from patient preprocedure and from collected products were assessed. (1) Product yield was calculated, (2) Product CBC was correlated with patient preprocedure variables, and (3) Predictions of CD34(+) yields based on (a) product CD34(+) cell concentration in samples after two or four chamber flushes or (b) traditional CE2 benchmark, were compared. 62 procedures in 41 patients were analyzed. 84% of all procedures were run without operator intervention. Median CD34(+) CE2 was 56.9% (48.8%-65.2%) and quite stable irrespective of patient conditions, with minor influence from patient white blood cell (WBC) precounts (r(s)=-.47; P<.001). Platelet loss correlated with WBC precount (r(s)=.46; P<.001), product volume (r(s)=.71; P<.0001) and number of chambers collected (r(s)=.72; P<.0001). CD34(+) cell yield was better predicted based on (a) product CD34(+) cell concentration from samples after 2 and 4 chamber flushes, respectively (r(s)=.969; P<.0001 and r(s)=.9648; P<.0001) than based on (b) CE2 formula (r(s)=.8262, P<.0001). Spectra Optia provides good quality PBSC products with stable and predictable yield regardless of starting conditions. CD34(+) sampling of product after few chamber flushes could be used to predict CD34(+) yield.
引用
收藏
页码:494 / 504
页数:11
相关论文
共 50 条
  • [31] Factors predicting engraftment of autologous blood stem cells:: CD34+ subsets inferior to the total CD34+ cell dose
    Stewart, DA
    Guo, D
    Luider, J
    Auer, I
    Klassen, J
    Ching, E
    Morris, D
    Chaudhry, A
    Brown, C
    Russell, JA
    BONE MARROW TRANSPLANTATION, 1999, 23 (12) : 1237 - 1243
  • [32] Factors predicting engraftment of autologous blood stem cells: CD34+ subsets inferior to the total CD34+ cell dose
    DA Stewart
    D Guo
    J Luider
    I Auer
    J Klassen
    E Ching
    D Morris
    A Chaudhry
    C Brown
    JA Russell
    Bone Marrow Transplantation, 1999, 23 : 1237 - 1243
  • [33] Optimised cord blood sample selection for small-scale CD34+ cell immunomagnetic isolation
    Perdomo-Arciniegas, Ana-Maria
    Vernot, Jean-Paul
    MOLECULAR MEDICINE REPORTS, 2012, 5 (03) : 749 - 752
  • [34] Timing of Peripheral Blood Stem Cell Yield: Comparison of Alternative Methods with the Classic Method for CD34+ Cell Determination
    Fatorova, I.
    Blaha, M.
    Lanska, M.
    Vokurkova, D.
    Rezacova, V.
    Zak, P.
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [35] Human CD4+CD25+ Cells in Combination with CD34+ Cells and Thymoglobulin to Prevent Anti-hematopoietic Stem Cell T Cell Alloreactivity
    Mahmud, Dolores
    Nicolini, Benedetta
    van den Dries, Lennert
    Mahmud, Nadim
    Arpinati, Mario
    Rondelli, Damiano
    BIOLOGY OF BLOOD AND MARROW TRANSPLANTATION, 2011, 17 (01) : 61 - 68
  • [36] Evaluation of the predictive value of the hematopoietic progenitor cell count using an automated hematology analyzer for CD34+stem cell mobilization and apheresis product yield
    Ramon Furundarena, Jose
    Uranga, Alasne
    Alkorta, Aitziber
    Gonzalez, Carmen
    Javier Ferreiro, Jose
    Rey, Mercedes
    Aragon, Larraitz
    Urreta, Iratxe
    Ignacio Emparanza, Jose
    Redin, Helena
    Garrido, Adolfo
    Araiz, Maria
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2020, 42 (02) : 170 - 179
  • [37] CD34+ Cell Mobilization, Autograft Cellular Composition and Outcome in Mantle Cell Lymphoma Patients
    Turunen, Antti Samuli
    Kuittinen, Outi
    Kuitunen, Hanne
    Vasala, Kaija
    Penttila, Karri
    Harmanen, Minna
    Keskinen, Leena
    Mantymaa, Pentti
    Pelkonen, Jukka
    Varmavuo, Ville
    Jantunen, Esa
    Partanen, Anu
    TRANSFUSION MEDICINE AND HEMOTHERAPY, 2023, : 428 - 437
  • [38] Absence of a CD34- hematopoietic precursor population in recipients of CD34+ stem cell transplantation
    Kato, S
    Ando, K
    Nakamura, Y
    Muguruma, Y
    Sato, T
    Yabe, H
    Yabe, M
    Hattori, K
    Yasuda, Y
    Hotta, T
    BONE MARROW TRANSPLANTATION, 2001, 28 (06) : 587 - 595
  • [39] Absence of a CD34− hematopoietic precursor population in recipients of CD34+ stem cell transplantation
    S Kato
    K Ando
    Y Nakamura
    Y Muguruma
    T Sato
    H Yabe
    M Yabe
    K Hattori
    Y Yasuda
    T Hotta
    Bone Marrow Transplantation, 2001, 28 : 587 - 595
  • [40] Predictors of the yield of mobilized peripheral blood CD34+ cells in HLA-matched sibling donor
    Fadilah, S. A. W.
    Mohd-Razif, M. I.
    Seery, Z. A. Z.
    Nor-Rafeah, T.
    Wan-Fariza, W. J.
    Habsah, A.
    Leong, C. F.
    TRANSFUSION AND APHERESIS SCIENCE, 2013, 49 (03) : 583 - 589