Histomorphometric Analysis of Hydroxyapatite-Coated Implants in Rabbit Cortical Bone Using Longitudinal and Transverse Histologic Sections

被引:1
|
作者
Rebollal, Julio
Soares, Gloria de Almeida [1 ]
Vidigal, Guaracilei Maciel, Jr. [2 ]
机构
[1] Univ Fed Rio de Janeiro, Dept Met & Mat, Rio De Janeiro, Brazil
[2] Unigranrio Univ, Sch Dent, Dept Oral Implantol, Duque De Caxias, Brazil
关键词
osseointegration; hydroxyapatite; histomorphometric analysis; dental implants; TITANIUM IMPLANTS; DENTAL IMPLANTS; BABOON JAWS; ANCHORAGE; OSSEOINTEGRATION; INTEGRATION;
D O I
10.1097/ID.0b013e3181cc4c3f
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to compare the osseointegration percentage of biomimetic hydroxyapatite (HA)-coated implants on longitudinal and transverse histologic sections using scanning electron microscopy. Materials and Methods: Ten commercially pure titanium dental implants, measuring 3.75 mm in diameter and 10 mm in length, were coated with HA by the biomimetic process and installed on the proximal metaphysis of the right tibia of 10 adult New Zealand female rabbits (Oryctolagus cunniculus). After a 3-month healing period, the animals were killed and the implants were removed together with the neighboring bone tissue. The specimens were than dehydrated on a crescent concentration of ethanol solution and embedded on resin. The osseointegration percentage of biomimetic HA-coated implants on 1 longitudinal and 1 transverse section were compared, using scanning electron microscopy and computerized histomorphometry. Results: It was verified that there were no statistically significant differences between the results of the different histological section directions (P > 0.05). Conclusion: Thus, in this study, the direction of histological sections did not affect bone-implant percentage. (Implant Dent 2010;19:137-144)
引用
收藏
页码:137 / 144
页数:8
相关论文
共 50 条
  • [41] Can the hydroxyapatite-coated skin-penetrating abutment for bone conduction hearing implants integrate with the surrounding skin?
    van Hoof', Marc
    Wigren, Stina
    Duimel, Hans
    Savelkoul, Paul H. M.
    Flynn, Mark
    Stokroos, Robert Jan
    FRONTIERS IN SURGERY, 2015, 2
  • [42] Evaluation of the Cortical Bone Reaction Around of Implants Using a Single-Use Final Drill: A Histologic Study
    Gehrke, Sergio Alexandre
    JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (05) : 1482 - 1486
  • [43] Microstructural analysis of implant-bone interface of hydroxyapatite-coated and uncoated Schanz screws
    M. Cimerman
    A. Cör
    M. Čveh
    A. Kristan
    J. Pižvem
    M. Tonin
    Journal of Materials Science: Materials in Medicine, 2005, 16 : 627 - 634
  • [44] Vertical bone augmentation induced by ultrathin hydroxyapatite sputtered coated mini titanium implants in a rabbit calvaria model
    Wang, Xin
    Zakaria, Osama
    Madi, Marwa
    Hao, Jia
    Chou, Joshua
    Kasugai, Shohei
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2015, 103 (08) : 1700 - 1708
  • [45] Histologic and histomorphometric analysis of the bone response to machined and sandblasted titanium implants: An experimental study in rabbits
    Piattelli, A
    Manzon, L
    Scarano, A
    Paolantonio, M
    Piattelli, M
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1998, 13 (06) : 805 - 810
  • [46] Histometric Analysis of Bone Repair in Bone-Implant Interface Using a Polylactic/Polyglycolic Acid Copolymer Associated With Implants in Rabbit Tibia
    Freire, Alexandre Rodrigues
    Rossi, Ana Claudia
    Queiroz, Thallita Pereira
    Gulinelli, Jessica Lemos
    Souza, Francisley Avila
    Margonar, Rogerio
    Garcia-Junior, Idelmo Rangel
    Hochuli-Vieira, Eduardo
    Okamoto, Roberta
    JOURNAL OF ORAL IMPLANTOLOGY, 2012, 38 (01) : 449 - 457
  • [47] Taking Hydroxyapatite-Coated Titanium Implants Two Steps Forward: Surface Modification Using Graphene Mesolayers and Hydroxyapatite-Reinforced Polymeric Scaffold
    Fathi, A. M.
    Ahmed, M. K.
    Afifi, M.
    Menazea, A. A.
    Uskokovic, Vuk
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2021, 7 (01): : 360 - 372
  • [48] Surface analysis and effects on interfacial bone microhardness of collagen-coated titanium implants: A rabbit model
    Morra, M
    Cassinelli, C
    Meda, L
    Fini, M
    Giavaresi, G
    Giardino, R
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2005, 20 (01) : 23 - 30
  • [49] The effect of Er:YAG laser irradiation on hydroxyapatite-coated implants and fluoride-modified TiO2-blasted implant surfaces: a microstructural analysis
    Shin, Seung-Il
    Lee, Eun-Kwon
    Kim, Jeong-Hyun
    Lee, Ji-Hun
    Kim, Sun-Hee
    Kwon, Young-Hyuk
    Herr, Yeek
    Chung, Jong-Hyuk
    LASERS IN MEDICAL SCIENCE, 2013, 28 (03) : 823 - 831
  • [50] Alveolar ridge augmentation using implants coated with recombinant human bone morphogenetic protein-2: histologic observations
    Wikesjoe, Ulf M. E.
    Qahash, Mohammed
    Polimeni, Giuseppe
    Susin, Cristiano
    Shanaman, Richard H.
    Rohrer, Michael D.
    Wozney, John M.
    Hall, Jan
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2008, 35 (11) : 1001 - 1010