Histomorphometric Analysis of Hydroxyapatite-Coated Implants in Rabbit Cortical Bone Using Longitudinal and Transverse Histologic Sections

被引:1
|
作者
Rebollal, Julio
Soares, Gloria de Almeida [1 ]
Vidigal, Guaracilei Maciel, Jr. [2 ]
机构
[1] Univ Fed Rio de Janeiro, Dept Met & Mat, Rio De Janeiro, Brazil
[2] Unigranrio Univ, Sch Dent, Dept Oral Implantol, Duque De Caxias, Brazil
关键词
osseointegration; hydroxyapatite; histomorphometric analysis; dental implants; TITANIUM IMPLANTS; DENTAL IMPLANTS; BABOON JAWS; ANCHORAGE; OSSEOINTEGRATION; INTEGRATION;
D O I
10.1097/ID.0b013e3181cc4c3f
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to compare the osseointegration percentage of biomimetic hydroxyapatite (HA)-coated implants on longitudinal and transverse histologic sections using scanning electron microscopy. Materials and Methods: Ten commercially pure titanium dental implants, measuring 3.75 mm in diameter and 10 mm in length, were coated with HA by the biomimetic process and installed on the proximal metaphysis of the right tibia of 10 adult New Zealand female rabbits (Oryctolagus cunniculus). After a 3-month healing period, the animals were killed and the implants were removed together with the neighboring bone tissue. The specimens were than dehydrated on a crescent concentration of ethanol solution and embedded on resin. The osseointegration percentage of biomimetic HA-coated implants on 1 longitudinal and 1 transverse section were compared, using scanning electron microscopy and computerized histomorphometry. Results: It was verified that there were no statistically significant differences between the results of the different histological section directions (P > 0.05). Conclusion: Thus, in this study, the direction of histological sections did not affect bone-implant percentage. (Implant Dent 2010;19:137-144)
引用
收藏
页码:137 / 144
页数:8
相关论文
共 50 条
  • [31] Porous-coated versus grit-blasted surface texture of hydroxyapatite-coated implants during controlled micromotion -: Mechanical and histomorphometric results
    Overgaard, S
    Lind, M
    Glerup, H
    Bünger, C
    Soballe, K
    JOURNAL OF ARTHROPLASTY, 1998, 13 (04) : 449 - 458
  • [32] Histologic and histomorphometric study of bone repair around short dental implants inserted in rabbit tibia, associated with tricalcium phosphate graft bone
    Lukiantchuki, Marlice Azoia
    Iwaki Filho, Liogi
    Vessoni Iwaki, Lilian Cristina
    Marcal Natali, Maria Raquel
    Sabio, Sergio
    Takeshita, Wilton Mitsunari
    ACTA SCIENTIARUM-HEALTH SCIENCES, 2014, 36 (02) : 257 - 263
  • [33] Bone Morphogenetic Protein-2 and Hyaluronic Acid on Hydroxyapatite-coated Porous Titanium to Repair the Defect of Rabbit's Distal Femu
    Lei, P.
    Zhao, M.
    Hui, L. F.
    Xi, W. M.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 1680 - +
  • [34] Histological and histochemical analyses of acid and alkaline phosphatases around hydroxyapatite-coated implants: a time course study in rabbit
    Piattelli, A
    Scarano, A
    DiAlberti, L
    Piattelli, M
    BIOMATERIALS, 1997, 18 (17) : 1191 - 1194
  • [35] Maxillary sinus augmentation using different grafting materials and dental implants in monkeys Part IV. Evaluation of hydroxyapatite-coated implants
    Quinones, CR
    Hurzeler, MB
    Schupbach, P
    Arnold, DR
    Strub, JR
    Caffesse, RG
    CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (06) : 497 - 505
  • [36] Improvement of the bone-screw interface strength with hydroxyapatite-coated and titanium-coated AO/ASIF cortical screws
    Moroni, A
    Faldini, C
    Rocca, M
    Stea, S
    Giannini, S
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (04) : 257 - 263
  • [37] Guided bone regeneration around titanium plasma-sprayed, acid-etched, and hydroxyapatite-coated implants in the canine model
    Conner, KA
    Sabatini, R
    Mealey, BL
    Takacs, VJ
    Mills, MP
    Cochran, DL
    JOURNAL OF PERIODONTOLOGY, 2003, 74 (05) : 658 - 668
  • [38] Tibial implants: biomechanical and histomorphometric studies of hydroxyapatite-coated and uncoated stainless steel and titanium screws in long-term ovariectomized sheep
    Rocca, M
    Fini, M
    Giavaresi, G
    Aldini, NN
    Giardino, R
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2001, 24 (09) : 649 - 654
  • [39] Histological and biomechanical analysis of bone and interface reactions around hydroxyapatite-coated intramedullary implants of different stiffness: a pilot study on the goat
    Buma, P
    vanLoon, PJM
    Versleyen, H
    Weinans, H
    Slooff, TJJH
    deGroot, K
    Huiskes, R