Technical Note: Deep learning based MRAC using rapid ultrashort echo time imaging

被引:48
|
作者
Jang, Hyungseok [1 ]
Liu, Fang [2 ]
Zhao, Gengyan [3 ]
Bradshaw, Tyler [2 ]
McMillan, Alan B. [2 ]
机构
[1] Univ Calif San Diego, Dept Radiol, 200 West Arbor Dr, San Diego, CA 92103 USA
[2] Univ Wisconsin, Sch Med & Publ Hlth, Dept Radiol, 600 Highland Ave, Madison, WI 53705 USA
[3] Univ Wisconsin, Sch Med & Publ Hlth, Dept Med Phys, 1111 Highland Ave, Madison, WI 53705 USA
基金
美国国家卫生研究院;
关键词
deep learning; MR-based attenuation correction; transfer learning; ATTENUATION-CORRECTION; AUTOMATIC SEGMENTATION; PET/MRI; ATLAS; IMAGES; RECONSTRUCTION; SYSTEMS; PET/CT; HEAD;
D O I
10.1002/mp.12964
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeIn this study, we explore the feasibility of a novel framework for MR-based attenuation correction for PET/MR imaging based on deep learning via convolutional neural networks, which enables fully automated and robust estimation of a pseudo CT image based on ultrashort echo time (UTE), fat, and water images obtained by a rapid MR acquisition. MethodsMR images for MRAC are acquired using dual echo ramped hybrid encoding (dRHE), where both UTE and out-of-phase echo images are obtained within a short single acquisition (35s). Tissue labeling of air, soft tissue, and bone in the UTE image is accomplished via a deep learning network that was pre-trained with T1-weighted MR images. UTE images are used as input to the network, which was trained using labels derived from co-registered CT images. The tissue labels estimated by deep learning are refined by a conditional random field based correction. The soft tissue labels are further separated into fat and water components using the two-point Dixon method. The estimated bone, air, fat, and water images are then assigned appropriate Hounsfield units, resulting in a pseudo CT image for PET attenuation correction. To evaluate the proposed MRAC method, PET/MR imaging of the head was performed on eight human subjects, where Dice similarity coefficients of the estimated tissue labels and relative PET errors were evaluated through comparison to a registered CT image. ResultDice coefficients for air (within the head), soft tissue, and bone labels were 0.760.03, 0.96 +/- 0.006, and 0.88 +/- 0.01. In PET quantitation, the proposed MRAC method produced relative PET errors less than 1% within most brain regions. ConclusionThe proposed MRAC method utilizing deep learning with transfer learning and an efficient dRHE acquisition enables reliable PET quantitation with accurate and rapid pseudo CT generation.
引用
收藏
页码:3697 / 3704
页数:8
相关论文
共 50 条
  • [1] PET Attenuation Correction Using Synthetic CT from Ultrashort Echo-Time MR Imaging
    Roy, Snehashis
    Wang, Wen-Tung
    Carass, Aaron
    Prince, Jerry L.
    Butman, John A.
    Pham, Dzung L.
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (12) : 2071 - 2077
  • [2] Rapid dual-echo ramped hybrid encoding MR-based attenuation correction (dRHE-MRAC) for PET/MR
    Jang, Hyungseok
    Liu, Fang
    Bradshaw, Tyler
    McMillan, Alan B.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (06) : 2912 - 2922
  • [3] MR-based PET attenuation correction using a combined ultrashort echo time/multi-echo Dixon acquisition
    Han, Paul Kyu
    Horng, Debra E.
    Gong, Kuang
    Petibon, Yoann
    Kim, Kyungsang
    Li, Quanzheng
    Johnson, Keith A.
    El Fakhri, Georges
    Ouyang, Jinsong
    Ma, Chao
    MEDICAL PHYSICS, 2020, 47 (07) : 3064 - 3077
  • [4] Rapid dual-RF, dual-echo, 3D ultrashort echo time craniofacial imaging: A feasibility study
    Lee, Hyunyeol
    Zhao, Xia
    Song, Hee Kwon
    Zhang, Rosaline
    Bartlett, Scott P.
    Wehrli, Felix W.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (05) : 3007 - 3016
  • [5] MR-Based Attenuation Correction Using Ultrashort-Echo-Time Pulse Sequences in Dementia Patients
    Cabello, Jorge
    Lukas, Mathias
    Foerster, Stefan
    Pyka, Thomas
    Nekolla, Stephan G.
    Ziegler, Sibylle I.
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03) : 423 - 429
  • [6] Assessment of hydrogen vehicle fuel economy using MRAC based on deep learning
    Han, Jaesu
    Yi, Sun
    Yu, Sangseok
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [7] MRI-based Attenuation Correction for Emission Tomography using Ultrashort Echo Time Sequences
    Keereman, Vincent
    Vanhove, Christian
    Vandenberghe, Stefaan
    EMAGRES, 2012, 1 (02): : 323 - 332
  • [8] MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences
    Keereman, Vincent
    Fierens, Yves
    Broux, Tom
    De Deene, Yves
    Lonneux, Max
    Vandenberghe, Stefaan
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (05) : 812 - 818
  • [9] DeepRegularizer: Rapid Resolution Enhancement of Tomographic Imaging Using Deep Learning
    Ryu, DongHun
    Ryu, Dongmin
    Baek, YoonSeok
    Cho, Hyungjoo
    Kim, Geon
    Kim, Young Seo
    Lee, Yongki
    Kim, Yoosik
    Ye, Jong Chul
    Min, Hyun-Seok
    Park, YongKeun
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (05) : 1508 - 1518
  • [10] Ramped Hybrid Encoding for Improved Ultrashort Echo Time Imaging
    Jang, Hyungseok
    Wiens, Curtis N.
    McMillan, Alan B.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (03) : 814 - 825