Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples

被引:23
|
作者
Yang, Suling [1 ]
Qu, Lingbo [1 ,2 ]
Yang, Ran [1 ]
Li, Jianjun [1 ]
Yu, Lanlan [1 ]
机构
[1] Zhengzhou Univ, Dept Chem, Zhengzhou 450001, Peoples R China
[2] Henan Univ Technol, Chem & Chem Engn Sch, Zhengzhou 450001, Peoples R China
基金
中国国家自然科学基金;
关键词
Paeonol; Nafion; Multi-wall carbon nanotubes; Voltammetry; STRIPPING VOLTAMMETRY; PASTE ELECTRODE; RAT PLASMA; PHENOL; CHROMATOGRAPHY; NANOTUBES; OXIDATION; TYROSINASE; MEDICINES; MOUTAN;
D O I
10.1007/s10800-010-0104-z
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A simple, highly sensitive method was reported for directly voltammetric determination of paeonol in drug samples and human biological samples. Nafion/multi-wall carbon nanotubes' (MWNTs) composite film was coated on the glassy carbon electrode. The adsorptive voltammetric behavior of paeonol on the Nafion/MWNTs-modified electrode was investigated using cyclic voltammetry (CV) and differential pulse anodic stripping voltammetry (DPASV). The results indicated that the Nafion/MWNTs-modified electrode could remarkably enhance electrocatalytic activity toward the oxidation of paeonol, and showed an excellent resistance capability toward the electrode passivation. A highly sensitive voltammetric sensor was developed for the detection of paeonol in pharmaceutical and biological samples. Under the optimum conditions, the anodic peak current was proportional to paeonol concentration in the range of 6.0 x 10(-7)-6.0 x 10(-5) M with a detection limit of 4.0 x 10(-7) M. Some kinetic parameters were determined, and multi-step mechanism for oxidation of paeonol was proposed.
引用
收藏
页码:1371 / 1378
页数:8
相关论文
共 50 条
  • [21] Potentiodynamic Poly(resorcinol)-Modified Glassy Carbon Electrode as a Voltammetric Sensor for Determining Cephalexin and Cefadroxil Simultaneously in Pharmaceutical Formulation and Biological Fluid Samples
    Kassa, Adane
    Amare, Meareg
    Benor, Amare
    Tigineh, Getinet Tamiru
    Beyene, Yonas
    Tefera, Molla
    Abebe, Atakilt
    ACS OMEGA, 2022, : 34599 - 34607
  • [22] Polymer Modified Carbon Paste Electrode as a Sensitive Sensor for the Electrochemical Determination of Riboflavin and Its Application in Pharmaceutical and Biological Samples
    D'Souza, Edwin S.
    Manjunatha, J. G.
    Raril, C.
    Tigari, Girish
    Pushpanjali, P. A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2020, 7 (04): : 461 - 472
  • [23] Pulse anodic stripping voltammetric determination of copper with an amoxicillin–nafion modified glassy carbon electrode
    A. A. Ramadan
    H. Mandil
    M. A. Saleh
    Journal of Applied Electrochemistry, 2008, 38 : 1715 - 1720
  • [24] The voltammetric sensor for sensitive determination of 8-hydroxyquinoline based on MWNTs/Nafion/GCE
    Zhou Yuanyuan
    Li Song
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2011, 5 (09): : 924 - 927
  • [25] A Sensitive Chlorpromazine Voltammetric Sensor Based on Graphene Oxide Modified Glassy Carbon Electrode
    Tajik, Somayeh
    Beitollahi, Hadi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2019, 6 (01): : 171 - 182
  • [26] Highly Sensitive and Selective Voltammetric Sensor Fullerene Modified Glassy Carbon Electrode for Determination of Cefitizoxime in Solubilized System
    Jain, Rajeev
    Rather, Jahangir Ahmad
    Dwivedi, Ashish
    Vikas
    ELECTROANALYSIS, 2010, 22 (21) : 2600 - 2606
  • [27] Voltammetric Determination of Arsenic with Modified Glassy Carbon Electrode
    Stankovic, Anamarija
    Kajinic, Zana
    Turkalj, Jelena Vesligaj
    Romic, Zeljka
    Sikiric, Maja Dutour
    Asserghine, Abdelilah
    Nagy, Geza
    Medvidovic-Kosanovic, Martina
    ELECTROANALYSIS, 2020, 32 (05) : 1043 - 1051
  • [28] Voltammetric determination of cefpirome at multiwalled carbon nanotube modified glassy carbon sensor based electrode in bulk form and pharmaceutical formulation
    Jain, Rajeev
    Vikas
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 87 (02) : 423 - 426
  • [29] Electrochemical Sensor Based on TiO2 Nanoparticles/Nafion Biocompatible Film Modified Glassy Carbon Electrode for Carbamazepine Determination in Pharmaceutical and Urine Samples
    Tarahomi, Somayeh
    Rounaghi, Gholam Hossein
    Zavar, Mohammad Hossein Arbab
    Daneshvar, Leili
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (16) : B946 - B952
  • [30] Electrochemical Sensor for Simple and Sensitive Determination of Hydroquinone in Water Samples Using Modified Glassy Carbon Electrode
    Karami-Kolmoti, Parisa
    Beitollahi, Hadi
    Modiri, Sina
    BIOMEDICINES, 2023, 11 (07)