Computer-aided Design of Distal Femoral Osteotomy for the Valgus Knee and Effect of Correction Angle on Joint Loading by Finite Element Analysis

被引:9
|
作者
Wu, Yanfei [1 ,2 ]
Jin, Xin [2 ]
Zhao, Xingwen [1 ,2 ]
Wang, Ying [2 ]
Bai, Haohao [2 ]
Lu, Bin [2 ]
Tong, Xue [2 ]
Ma, Jianxiong [2 ]
Ma, Xinlong [1 ,2 ]
机构
[1] Tianjin Med Univ, Clin Coll Orthoped, Tianjin, Peoples R China
[2] Tianjin Univ, Tianjin Hosp, Tianjin, Peoples R China
基金
中国国家自然科学基金;
关键词
Cartilage; Finite element analysis; Meniscus; Shear stress; Von Mises; CARTILAGE; MODEL; OSTEOARTHRITIS; STRESS;
D O I
10.1111/os.13440
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective Lateral open-wedge distal femoral osteotomy (DFO) has been used to treat valgus deformity of the knee, with good clinical outcomes. However, there is a lack of biomechanical studies regarding the angle of correction. The objective of this study was to apply computer-aided design (CAD) for osteotomy planning in a three-dimensional (3D) anatomical model and to assess the biomechanical differences among the varying correction angles on joint loading by finite element analysis (FEA). Methods To model different angles of lateral open-wedge DFO correction, the CAD software package Mimics 21.0 was used to accurately simulate the operated knee. The femur was cut to 0 degrees, 2 degrees, 4 degrees, 6 degrees, 8 degrees, and 10 degrees of varus (equivalent to hip-knee-ankle angles of 180 degrees, 178 degrees, 176 degrees, 174 degrees, 172 degrees, and 170 degrees, respectively). The original knee model and the corrected models were processed by FE software. Then, the FE models were subjected to an axial force to obtain the von Mises stress (VMS) and shear stress distributions within the femoral cartilages and menisci. Results Under a compressive load of 740 N, the highest VMS in lateral and medial compartments of the intact knee model was 3.418 and 3.303 MPa. The maximum value of both the VMS and the shear stress in the lateral compartment decreased as the varus angle increased, but the corresponding values in the medial compartment increased. When the hip-knee-ankle (HKA) angle was 180 degrees, the VMS in the lateral and medial compartments was balanced (3.418 and 3.303 MPa, respectively). Meanwhile, when the HKA angle was 178 degrees (3.488 and 3.625 MPa, respectively), the shear stress in the lateral and medial compartments was balanced. In addition, the magnitude of change in the stress was significantly higher in the medial compartment (90.9%) than in the lateral compartment (19.3%). Conclusion The optimal correction angle of the valgus knee is close to neutral alignment or slightly varus (0 degrees - 2 degrees). Overcorrection is not recommended, as it can result in a steep increase of the stress within the medial compartment and may accelerate the process of medial compartment OA.
引用
收藏
页码:2904 / 2913
页数:10
相关论文
共 50 条
  • [1] Finite element analysis of the valgus knee joint of an obese child
    Sun, Jun
    Yan, Songhua
    Jiang, Yan
    Wong, Duo Wai-chi
    Zhang, Ming
    Zeng, Jizhou
    Zhang, Kuan
    BIOMEDICAL ENGINEERING ONLINE, 2016, 15
  • [2] Finite element analysis of the effect of high tibial osteotomy correction angle on articular cartilage loading
    Trad, Zahra
    Barkaoui, Abdelwahed
    Chafra, Moez
    Tavares, Joao Manuel R. S.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2018, 232 (06) : 553 - 564
  • [3] Distal femoral varus osteotomy for unloading valgus knee malalignment: a biomechanical analysis
    Quirno, Martin
    Campbell, Kirk A.
    Singh, Brian
    Hasan, Saqib
    Jazrawi, Laith
    Kummer, Fredrick
    Strauss, Eric J.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (03) : 863 - 868
  • [4] Distal femoral varus osteotomy for unloading valgus knee malalignment: a biomechanical analysis
    Martin Quirno
    Kirk A. Campbell
    Brian Singh
    Saqib Hasan
    Laith Jazrawi
    Fredrick Kummer
    Eric J. Strauss
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 863 - 868
  • [5] Finite element analysis of human knee joint in varus-valgus
    Bendjaballah, MZ
    ShiraziAdl, A
    Zukor, DJ
    CLINICAL BIOMECHANICS, 1997, 12 (03) : 139 - 148
  • [6] Finite Element Analysis of the Effect of Femoral Prosthesis Varus and Valgus Angle Installation on the Lateral Compartment in Unicompartmental Knee Arthroplasty
    Wang, Yonggui
    Xu, Chongyang
    Yang, Bo
    Yu, Fei
    Guo, Ai
    JOURNAL OF NIPPON MEDICAL SCHOOL, 2024, 91 (01) : 88 - 98
  • [7] Finite element analysis of biomechanical effects of residual varus/valgus malunion after femoral fracture on knee joint
    Kai Ding
    Weijie Yang
    Haicheng Wang
    Shi Zhan
    Pan Hu
    Junsheng Bai
    Chuan Ren
    Qi Zhang
    Yanbin Zhu
    Wei Chen
    International Orthopaedics, 2021, 45 : 1827 - 1835
  • [8] Finite element analysis of biomechanical effects of residual varus/valgus malunion after femoral fracture on knee joint
    Ding, Kai
    Yang, Weijie
    Wang, Haicheng
    Zhan, Shi
    Hu, Pan
    Bai, Junsheng
    Ren, Chuan
    Zhang, Qi
    Zhu, Yanbin
    Chen, Wei
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (07) : 1827 - 1835
  • [9] Design of a custom angled abutment for dental implants using computer-aided design and nonlinear finite element analysis
    Wu, Ting
    Liao, Wenhe
    Dai, Ning
    Tang, Chunbo
    JOURNAL OF BIOMECHANICS, 2010, 43 (10) : 1941 - 1946
  • [10] Biomechanical Effect of Distal Tibial Oblique Osteotomy: A Preliminary Finite-Element Analysis
    Sakai, Tatsuya
    Fujii, Masanori
    Kitamura, Kenji
    Tanaka, Hirofumi
    Mawatari, Masaaki
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (02)