Experimental investigation of a stainless steel two-phase closed thermosyphon

被引:51
作者
Lataoui, Zied [1 ]
Jemni, Abdelmajid [1 ]
机构
[1] Univ Monastir, LESTE, Ecole Natl Ingenieurs Monastir, Rue Ibn ElJazzar 5019, Monastir, Tunisia
关键词
Thermosyphon; Filling ratio; Working fluid; Thermal characteristics; HEAT-TRANSFER PERFORMANCE; THERMAL PERFORMANCE; FILLING RATIOS; FILM;
D O I
10.1016/j.applthermaleng.2017.04.135
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental investigation has been carried out to study the heat transfer characteristics of a stainless steel two-phase closed thermosyphon. Three compatible working fluids were tested: water, ethanol and acetone. Since the filling ratio is expected to have a predominant effect on the steady-state thermal performance of a thermosyphon, three cases were considered: the underfilled, overfilled and optimally-filled sets. The effects of the input heat flux at the evaporator and the cooling fluid temperature at the condenser were also investigated. The steady state wall temperature was then monitored at various locations along the thermosyphon. The obtained results showed that the dry-out occurrence at the evaporator bottom resulted in an obvious temperature rise, especially for the underfilled case. The experimental heat transfer coefficient at the evaporator was estimated and compared with pool boiling correlation data. A good agreement between the experimental results and the prediction values was obtained for ethanol. A reasonable agreement was found for water and acetone. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:721 / 727
页数:7
相关论文
共 25 条
[1]   Heat pipe-based cooling systems for photovoltaic cells under concentrated solar radiation [J].
Akbarzadeh, A ;
Wadowski, T .
APPLIED THERMAL ENGINEERING, 1996, 16 (01) :81-87
[2]   Numerical investigation of effect of fill ratio and inclination angle on a thermosiphon heat pipe thermal performance [J].
Alammar, Ahmed A. ;
Al-Dadah, Raya K. ;
Mahmoud, Saad M. .
APPLIED THERMAL ENGINEERING, 2016, 108 :1055-1065
[3]  
Baojin Q., 2009, ENERG CONVERS MANAGE, V50, P2147
[4]   Experimental investigation of thermosyphon loop thermal performance [J].
Chehade, A. A. ;
Louahlia-Gualous, H. ;
Le Masson, S. ;
Victor, I. ;
Abouzahab-Darnaj, N. .
ENERGY CONVERSION AND MANAGEMENT, 2014, 84 :671-680
[5]   Heat transfer correlations for liquid film in the evaporator of enclosed, gravity-assisted thermosyphons [J].
El-Genk, MS ;
Saber, HH .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1998, 120 (02) :477-484
[6]  
Faghri Amir., 1995, HEAT PIPE SCI TECHNO
[7]  
Harada K., 1980, HITACHI ZOSEN TECH R, V41, P167
[8]   COMPLETE TRANSIENT 2-DIMENSIONAL ANALYSIS OF 2-PHASE CLOSED THERMOSIPHONS INCLUDING THE FALLING CONDENSATE FILM [J].
HARLEY, C ;
FAGHRI, A .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1994, 116 (02) :418-426
[9]   Performance of wickless heat pipe flat plate solar collectors having different pipes cross sections geometries and filling ratios [J].
Hussein, HMS ;
El-Ghetany, HH ;
Nada, SA .
ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (11-12) :1539-1549
[10]   CRITICAL HEAT-FLUX IN A CLOSED 2-PHASE THERMOSYPHON [J].
IMURA, H ;
SASAGUCHI, K ;
KOZAI, H ;
NUMATA, S .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1983, 26 (08) :1181-1188