A prediction model using machine-learning algorithm for assessing intrathecal hyperbaric bupivacaine dose during cesarean section

被引:8
作者
Wei, Chang-na [1 ]
Wang, Li-ying [1 ]
Chang, Xiang-yang [1 ]
Zhou, Qing-he [2 ]
机构
[1] Jiaxing Univ, Affiliated Women & Children Hosp, Dept Anesthesia, Jiaxing, Zhejiang, Peoples R China
[2] Jiaxing Univ, Affiliated Hosp, Dept Anesthesia, Jiaxing, Zhejiang, Peoples R China
关键词
Machine learning algorithm; Bupivacaine dosage; Cesarean section; Spinal anesthesia; Physical variables;
D O I
10.1186/s12871-021-01331-8
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background The intrathecal hyperbaric bupivacaine dosage for cesarean section is difficult to predetermine. This study aimed to develop a decision-support model using a machine-learning algorithm for assessing intrathecal hyperbaric bupivacaine dose based on physical variables during cesarean section. Methods Term parturients presenting for elective cesarean section under spinal anaesthesia were enrolled. Spinal anesthesia was performed at the L3/4 interspace with 0.5% hyperbaric bupivacaine at dosages determined by the anesthesiologist. A spinal spread level between T4-T6 was considered the appropriate block level. We used a machine-learning algorithm to identify relevant parameters. The dataset was split into derivation (80%) and validation (20%) cohorts. A decision-support model was developed for obtaining the regression equation between optimized intrathecal 0.5% hyperbaric bupivacaine volume and physical variables. Results A total of 684 parturients were included, of whom 516 (75.44%) and 168 (24.56%) had block levels between T4 and T6, and less than T6 or higher than T4, respectively. The appropriate block level rate was 75.44%, with the mean bupivacaine volume [1.965, 95%CI (1.945,1.984)]ml. In lasso regression, based on the principle of predicting a reasonable dose of intrathecal bupivacaine with fewer physical variables, the model is "Y=0.5922+ 0.055117* X-1-0.017599*X-2" (Y: bupivacaine volume; X-1: vertebral column length; X-2: abdominal girth), with lambda 0.055, MSE 0.0087, and R-2 0.807. Conclusions After applying a machine-learning algorithm, we developed a decision model with R-2 0.8070 and MSE due to error 0.0087 using abdominal girth and vertebral column length for predicting the optimized intrathecal 0.5% hyperbaric bupivacaine dosage during term cesarean sections.
引用
收藏
页数:7
相关论文
共 24 条
[11]   Prevention of hypotension during spinal anesthesia for cesarean delivery - An effective technique using combination phenylephrine infusion and crystalloid cohydration [J].
Kee, WDN ;
Khaw, KS ;
Ng, FF .
ANESTHESIOLOGY, 2005, 103 (04) :744-750
[12]   Supervised Machine-learning Predictive Analytics for Prediction of Postinduction Hypotension [J].
Kendale, Samir ;
Kulkarni, Prathamesh ;
Rosenberg, Andrew D. ;
Wang, Jing .
ANESTHESIOLOGY, 2018, 129 (04) :675-688
[13]   PATIENT VARIABLES AND THE SUBARACHNOID SPREAD OF HYPERBARIC BUPIVACAINE IN THE TERM PARTURIENT [J].
NORRIS, MC .
ANESTHESIOLOGY, 1990, 72 (03) :478-482
[14]  
NORRIS MC, 1988, ANESTH ANALG, V67, P555
[15]   Assessment of block height for satisfactory spinal anaesthesia for caesarean section [J].
Ousley, R. ;
Egan, C. ;
Dowling, K. ;
Cyna, A. M. .
ANAESTHESIA, 2012, 67 (12) :1356-1363
[16]   A REEVALUATION OF THE ROLE OF CRYSTALLOID PRELOAD IN THE PREVENTION OF HYPOTENSION ASSOCIATED WITH SPINAL-ANESTHESIA FOR ELECTIVE CESAREAN-SECTION [J].
ROUT, CC ;
ROCKE, DA ;
LEVIN, J ;
GOUWS, E ;
REDDY, D .
ANESTHESIOLOGY, 1993, 79 (02) :262-269
[17]   SUBARACHNOID ANALGESIA FOR CESAREAN-SECTION - A DOUBLE-BLIND COMPARISON OF PLAIN AND HYPERBARIC 0.5-PERCENT BUPIVACAINE [J].
RUSSELL, IF ;
HOLMQVIST, ELO .
BRITISH JOURNAL OF ANAESTHESIA, 1987, 59 (03) :347-353
[18]   Comparison of spinal anesthesia dosage based on height and weight versus height alone in patients undergoing elective cesarean section [J].
Siddiqui, Khalid Maudood ;
Ali, Muhammad Asghar ;
Ullah, Hameed .
KOREAN JOURNAL OF ANESTHESIOLOGY, 2016, 69 (02) :143-148
[19]   Compression of the subarachnoid space by the engorged epidural venous plexus in pregnant women [J].
Takiguchi, Tetsuo ;
Yamaguchi, Shigeki ;
Tezuka, Masatomo ;
Furukawa, Naoki ;
Kitajima, Toshimitsu .
ANESTHESIOLOGY, 2006, 105 (04) :848-851
[20]   Small-dose hyperbaric versus plain bupivacaine during spinal anesthesia for cesarean section [J].
Vercauteren, MP ;
Coppejans, HC ;
Hoffmann, VL ;
Saldien, V ;
Adriaensen, HA .
ANESTHESIA AND ANALGESIA, 1998, 86 (05) :989-993