Comparison Between Locking and Non-Locking Plates for Fixation of Metacarpal Fractures in an Animal Model

被引:30
作者
Ochman, Sabine
Doht, Stephanie
Paletta, Juergen
Langer, Martin
Raschke, Michael J.
Meffert, Rainer H.
机构
[1] Univ Hosp, Dept Trauma Hand & Reconstruct Surg, Munster, Germany
[2] Univ Wurzburg, Dept Trauma Hand Plast & Reconstruct Surg, Wurzburg, Germany
[3] Dept Orthoped Surg, Marburg, Germany
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2010年 / 35A卷 / 04期
关键词
Biomechanics; fracture; internal fixation; locking plate; metacarpal; DISTAL RADIUS FRACTURES; INTERNAL-FIXATION; PHALANGEAL FRACTURES; HAND FRACTURES; PROXIMAL HUMERUS; SCREW FIXATION; COMPLICATIONS; STIFFNESS; CONSTRUCT; FAILURE;
D O I
10.1016/j.jhsa.2010.01.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The use of locking plates increases the primary load to failure, thereby reducing the rate of implant-related failure. The good clinical and biomechanical results of locking plates in long bones might be applicable to treatment of metacarpal fractures. The purpose of this study was to determine strength and stiffness of locking plates in a metacarpal fracture model with mono- and bicortical screw fixation in comparison to non-locking plate mono- and bicortical screw fixation, with both types of plates placed at the dorsal side of the bone. Methods Fresh second metacarpals from domestic pigs (n=40) were randomized in 4 equal groups. Short, oblique, mid-shaft fractures were generated, using a standardized 3-point bending method. Fractures were plated with non-locking, titanium, 1-mm-thick monocortical (group 1, n=10) or bicortical (group 2, n = 10) plates (Leibinger-Stryker; Stryker Corp, Freiburg, Germany). Newly designed locking titanium plates with the same width and thickness (Leibinger-Stryker) were used in the same manner for groups 3 (monocortical) and 4 (bicortical). The metacarpals were then tested to load to failure in a cantilever bending mode. Results Bicortical, non-locking fixation (group 2, 359 +/- 90 N) had a higher load to failure than monocortical non-locking fixation (group 1, 250 +/- 56 N) in testing the maximum load to failure (p < .01). There was no significant difference in stiffness between group 1 (46 +/- 12 N/mm) and group 2 (56 +/- 21 N/mm). The difference in maximum load to failure between monocortical (group 3, 440 +/- 85N) and bicortical (group 4, 378 +/- 116 N) locking plate stabilization was not significant. Also, there was no significant difference in stiffness between monocortical (group 3, 83 +/- 35 N/mm) and bicortical locking plates (group 4, 70 +/- 31 N/mm). Comparing non-locking (group 1) and locking plates in a monocortical fixation technique (group 3) demonstrated significant differences in maximum load to failure (group 1, 250 +/- 56 N; group 3, 440 +/- 85 N) and stiffness (group 1, 46 +/- 12 N/mm; group 3, 83 +/- 35 N/mm). The stability of monocortical locking plates was stronger, although not statistically significant, than the non-locking bicortical plates (load to failure, 440 +/- 85 N vs 359 +/- 90 N; stiffness, 83 +/- 35 N/mm vs 56 +/- 21 N/mm). Conclusions The new generation of locking plates can be used to achieve a higher stability for fixation of metacarpal fractures. Monocortical, stable fixation can minimize flexor tendon interference and probably reduce bone and soft tissue trauma. (J Hand Surg 2010;35A:597-603. Copyright (C) 2010 by the American Society for Surgery of the Hand. All rights reserved.)
引用
收藏
页码:597 / 603
页数:7
相关论文
共 50 条
  • [31] Locking retrograde nail, non-locking retrograde nail and plate fixation in the treatment of distal third femoral shaft fractures: radiographic, bone densitometry and clinical outcomes
    Meccariello, Luigi
    Bisaccia, Michele
    Ronga, Mario
    Falzarano, Gabriele
    Caraffa, Auro
    Rinonapoli, Giuseppe
    Grubor, Predrag
    Pace, Valerio
    Rollo, Giuseppe
    [J]. JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2021, 22 (01)
  • [32] PALMAR FIXATION OF DORSALLY DISPLACED DISTAL RADIUS FRACTURES USING LOCKING PLATES WITH SMARTLOCK LOCKING SCREWS
    Wong, T. C.
    Yeung, C. C.
    Chiu, Y.
    Yeung, S. H.
    Ip, F. K.
    [J]. JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2009, 34E (02) : 173 - 178
  • [33] Tibial plateau fractures: Internal fixation with locking plates and the MIPO technique
    Biggi, F.
    Di Fabio, S.
    D'Antimo, C.
    Trevisani, S.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (11): : 1178 - 1182
  • [34] Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: A biomechanical study in cadavers
    Blythe, Murray
    Stoffel, Karl
    Jarrett, Paul
    Kuster, Markus
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (10): : 1587 - 1593
  • [35] Periprosthetic supracondylar femoral fractures above total knee arthroplasty: comparison of the locking and non-locking plating methods
    Bae, Dae Kyung
    Song, Sang Jun
    Yoon, Kyoung Ho
    Kim, Tae Yong
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (11) : 2690 - 2697
  • [36] Periprosthetic supracondylar femoral fractures above total knee arthroplasty: comparison of the locking and non-locking plating methods
    Dae Kyung Bae
    Sang Jun Song
    Kyoung Ho Yoon
    Tae Yong Kim
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 2690 - 2697
  • [37] Is Locking Nailing of Humeral Head Fractures Superior to Locking Plate Fixation?
    Gradl, G.
    Dietze, A.
    Kaeaeb, M.
    Hopfenmueller, W.
    Mittlmeier, T.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (11) : 2986 - 2993
  • [38] Biomechanical study of the fixation ability of the dorsal and volar locking plate for transverse metacarpal neck fractures
    Ho, Tsung-Yu
    Hsu, Cheng-En
    Wang, Wei-Chih
    Ting, Yen-Nien
    Tsai, Ming-Tzu
    Chiu, Yung-Cheng
    Hsu, Jui-Ting
    [J]. MEDICINE, 2023, 102 (36) : E34981
  • [39] Fixation of periprosthetic or osteoporotic distal femoral fractures with locking plates: a pilot randomised controlled trial
    Kanakaris, Nikolaos K.
    Obakponovwe, Oghofori
    Krkovic, Matija
    Costa, Matt L.
    Shaw, David
    Mohanty, Khitish R.
    West, Robert M.
    Giannoudis, Peter V.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2019, 43 (05) : 1193 - 1204
  • [40] Locking Plates for Extremity Fractures
    Anglen, Jeffrey
    Kyle, Richard F.
    Marsh, John Lawrence
    Virkus, Walter W.
    Watters, William C., III
    Keith, Michael Warren
    Turkelson, Charles M.
    Wies, Janet L.
    Boyer, Kevin M.
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2009, 17 (07) : 465 - 472