Comparison Between Locking and Non-Locking Plates for Fixation of Metacarpal Fractures in an Animal Model

被引:30
作者
Ochman, Sabine
Doht, Stephanie
Paletta, Juergen
Langer, Martin
Raschke, Michael J.
Meffert, Rainer H.
机构
[1] Univ Hosp, Dept Trauma Hand & Reconstruct Surg, Munster, Germany
[2] Univ Wurzburg, Dept Trauma Hand Plast & Reconstruct Surg, Wurzburg, Germany
[3] Dept Orthoped Surg, Marburg, Germany
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2010年 / 35A卷 / 04期
关键词
Biomechanics; fracture; internal fixation; locking plate; metacarpal; DISTAL RADIUS FRACTURES; INTERNAL-FIXATION; PHALANGEAL FRACTURES; HAND FRACTURES; PROXIMAL HUMERUS; SCREW FIXATION; COMPLICATIONS; STIFFNESS; CONSTRUCT; FAILURE;
D O I
10.1016/j.jhsa.2010.01.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The use of locking plates increases the primary load to failure, thereby reducing the rate of implant-related failure. The good clinical and biomechanical results of locking plates in long bones might be applicable to treatment of metacarpal fractures. The purpose of this study was to determine strength and stiffness of locking plates in a metacarpal fracture model with mono- and bicortical screw fixation in comparison to non-locking plate mono- and bicortical screw fixation, with both types of plates placed at the dorsal side of the bone. Methods Fresh second metacarpals from domestic pigs (n=40) were randomized in 4 equal groups. Short, oblique, mid-shaft fractures were generated, using a standardized 3-point bending method. Fractures were plated with non-locking, titanium, 1-mm-thick monocortical (group 1, n=10) or bicortical (group 2, n = 10) plates (Leibinger-Stryker; Stryker Corp, Freiburg, Germany). Newly designed locking titanium plates with the same width and thickness (Leibinger-Stryker) were used in the same manner for groups 3 (monocortical) and 4 (bicortical). The metacarpals were then tested to load to failure in a cantilever bending mode. Results Bicortical, non-locking fixation (group 2, 359 +/- 90 N) had a higher load to failure than monocortical non-locking fixation (group 1, 250 +/- 56 N) in testing the maximum load to failure (p < .01). There was no significant difference in stiffness between group 1 (46 +/- 12 N/mm) and group 2 (56 +/- 21 N/mm). The difference in maximum load to failure between monocortical (group 3, 440 +/- 85N) and bicortical (group 4, 378 +/- 116 N) locking plate stabilization was not significant. Also, there was no significant difference in stiffness between monocortical (group 3, 83 +/- 35 N/mm) and bicortical locking plates (group 4, 70 +/- 31 N/mm). Comparing non-locking (group 1) and locking plates in a monocortical fixation technique (group 3) demonstrated significant differences in maximum load to failure (group 1, 250 +/- 56 N; group 3, 440 +/- 85 N) and stiffness (group 1, 46 +/- 12 N/mm; group 3, 83 +/- 35 N/mm). The stability of monocortical locking plates was stronger, although not statistically significant, than the non-locking bicortical plates (load to failure, 440 +/- 85 N vs 359 +/- 90 N; stiffness, 83 +/- 35 N/mm vs 56 +/- 21 N/mm). Conclusions The new generation of locking plates can be used to achieve a higher stability for fixation of metacarpal fractures. Monocortical, stable fixation can minimize flexor tendon interference and probably reduce bone and soft tissue trauma. (J Hand Surg 2010;35A:597-603. Copyright (C) 2010 by the American Society for Surgery of the Hand. All rights reserved.)
引用
收藏
页码:597 / 603
页数:7
相关论文
共 50 条
  • [21] Fixation of fifth metacarpal neck fractures: a comparison of medial locking plates with intramedullary K-wires
    Chen, Kuan-Jung
    Wang, Jung-Pan
    Yin, Cheng-Yu
    Huang, Hui-Kuang
    Chang, Ming-Chau
    Huang, Yi-Chao
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (06) : 567 - 573
  • [22] Locking Compression Plates are more difficult to remove than conventional non-locking plates
    G. D. Musters
    P. Boele van Hensbroek
    K. J. Ponsen
    J. S. K. Luitse
    J. C. Goslings
    European Journal of Trauma and Emergency Surgery, 2013, 39 : 159 - 162
  • [23] Locking versus non-locking one-third tubular plates for treating osteoporotic distal fibula fractures: a comparative study
    Herrera-Perez, Mario
    Gutierrez-Morales, Maria J.
    Guerra-Ferraz, Ayron
    Pais-Brito, Jose L.
    Boluda-Mengod, Juan
    Garces, Gerardo L.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 : S60 - S65
  • [24] Short-term outcomes of 59 dogs treated for ilial body fractures with locking or non-locking plates
    Petrovsky, Brian
    Knuth, Taylor
    Aponte-Colon, Cristina
    Hoefle, William
    Kraus, Karl
    Naiman, Jaron
    Yuan, Lingnan
    Mochel, Jonathan P.
    Zellner, Eric
    VETERINARY SURGERY, 2021, 50 (05) : 1076 - 1086
  • [25] Comparison of Locking Versus Nonlocking Plates for Distal Fibula Fractures
    Lyle, Shirley A.
    Malik, Catherine
    Oddy, Michael J.
    JOURNAL OF FOOT & ANKLE SURGERY, 2018, 57 (04) : 664 - 667
  • [26] Biomechanical comparison of conventional and optimised locking plates for the fixation of intraarticular calcaneal fractures: a finite element analysis
    Ouyang, Hanbin
    Deng, Yuping
    Xie, Pusheng
    Yang, Yang
    Jiang, Bingyun
    Zeng, Canjun
    Huang, Wenhua
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 (12) : 1339 - 1349
  • [27] A biomechanical comparison of locking and nonlocking plates for the fixation of calcaneal fractures
    Redfern, DJ
    Oliveira, MLR
    Campbell, JT
    Belkoff, SM
    FOOT & ANKLE INTERNATIONAL, 2006, 27 (03) : 196 - 201
  • [28] Biomechanical study of four palmar locking plates and one non-locking palmar plate for distal radius fractures: stiffness and load to failure tests in a cadaver model
    Rudig, Lothar
    Mehling, Isabella
    Klitscher, Daniela
    Mehler, Dorothea
    Prommersberger, Karl-Josef
    Rommens, Pol M.
    Mueller, Lars Peter
    BIOMEDIZINISCHE TECHNIK, 2009, 54 (03): : 150 - 158
  • [29] Locking plates for fixation of extra-articular fractures of the first metacarpal base: A series of 15 cases
    Diaconu, M.
    Facca, S.
    Gouzou, S.
    Liverneaux, Ph.
    CHIRURGIE DE LA MAIN, 2011, 30 (01) : 26 - 30
  • [30] Locking retrograde nail, non-locking retrograde nail and plate fixation in the treatment of distal third femoral shaft fractures: radiographic, bone densitometry and clinical outcomes
    Meccariello, Luigi
    Bisaccia, Michele
    Ronga, Mario
    Falzarano, Gabriele
    Caraffa, Auro
    Rinonapoli, Giuseppe
    Grubor, Predrag
    Pace, Valerio
    Rollo, Giuseppe
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2021, 22 (01)