Comparison Between Locking and Non-Locking Plates for Fixation of Metacarpal Fractures in an Animal Model

被引:30
|
作者
Ochman, Sabine
Doht, Stephanie
Paletta, Juergen
Langer, Martin
Raschke, Michael J.
Meffert, Rainer H.
机构
[1] Univ Hosp, Dept Trauma Hand & Reconstruct Surg, Munster, Germany
[2] Univ Wurzburg, Dept Trauma Hand Plast & Reconstruct Surg, Wurzburg, Germany
[3] Dept Orthoped Surg, Marburg, Germany
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2010年 / 35A卷 / 04期
关键词
Biomechanics; fracture; internal fixation; locking plate; metacarpal; DISTAL RADIUS FRACTURES; INTERNAL-FIXATION; PHALANGEAL FRACTURES; HAND FRACTURES; PROXIMAL HUMERUS; SCREW FIXATION; COMPLICATIONS; STIFFNESS; CONSTRUCT; FAILURE;
D O I
10.1016/j.jhsa.2010.01.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The use of locking plates increases the primary load to failure, thereby reducing the rate of implant-related failure. The good clinical and biomechanical results of locking plates in long bones might be applicable to treatment of metacarpal fractures. The purpose of this study was to determine strength and stiffness of locking plates in a metacarpal fracture model with mono- and bicortical screw fixation in comparison to non-locking plate mono- and bicortical screw fixation, with both types of plates placed at the dorsal side of the bone. Methods Fresh second metacarpals from domestic pigs (n=40) were randomized in 4 equal groups. Short, oblique, mid-shaft fractures were generated, using a standardized 3-point bending method. Fractures were plated with non-locking, titanium, 1-mm-thick monocortical (group 1, n=10) or bicortical (group 2, n = 10) plates (Leibinger-Stryker; Stryker Corp, Freiburg, Germany). Newly designed locking titanium plates with the same width and thickness (Leibinger-Stryker) were used in the same manner for groups 3 (monocortical) and 4 (bicortical). The metacarpals were then tested to load to failure in a cantilever bending mode. Results Bicortical, non-locking fixation (group 2, 359 +/- 90 N) had a higher load to failure than monocortical non-locking fixation (group 1, 250 +/- 56 N) in testing the maximum load to failure (p < .01). There was no significant difference in stiffness between group 1 (46 +/- 12 N/mm) and group 2 (56 +/- 21 N/mm). The difference in maximum load to failure between monocortical (group 3, 440 +/- 85N) and bicortical (group 4, 378 +/- 116 N) locking plate stabilization was not significant. Also, there was no significant difference in stiffness between monocortical (group 3, 83 +/- 35 N/mm) and bicortical locking plates (group 4, 70 +/- 31 N/mm). Comparing non-locking (group 1) and locking plates in a monocortical fixation technique (group 3) demonstrated significant differences in maximum load to failure (group 1, 250 +/- 56 N; group 3, 440 +/- 85 N) and stiffness (group 1, 46 +/- 12 N/mm; group 3, 83 +/- 35 N/mm). The stability of monocortical locking plates was stronger, although not statistically significant, than the non-locking bicortical plates (load to failure, 440 +/- 85 N vs 359 +/- 90 N; stiffness, 83 +/- 35 N/mm vs 56 +/- 21 N/mm). Conclusions The new generation of locking plates can be used to achieve a higher stability for fixation of metacarpal fractures. Monocortical, stable fixation can minimize flexor tendon interference and probably reduce bone and soft tissue trauma. (J Hand Surg 2010;35A:597-603. Copyright (C) 2010 by the American Society for Surgery of the Hand. All rights reserved.)
引用
收藏
页码:597 / 603
页数:7
相关论文
共 50 条
  • [1] Biomechanical Comparison of Double-Row Locking Plates Versus Single- and Double-Row Non-Locking Plates in a Comminuted Metacarpal Fracture Model
    Gajendran, Varun K.
    Szabo, Robert M.
    Myo, George K.
    Curtiss, Shane B.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (10): : 1851 - 1858
  • [2] Stability of Locking and Non-Locking Plates in an Osteoporotic Calcaneal Fracture Model
    Illert, Till
    Rammelt, Stefan
    Drewes, Tim
    Grass, Rene
    Zwipp, Hans
    FOOT & ANKLE INTERNATIONAL, 2011, 32 (03) : 307 - 313
  • [3] A comparison of complication rates between locking and non-locking plates in distal fibular fractures
    Moriarity, A.
    Ellanti, P.
    Mohan, K.
    Fhoghlu, C. Ni
    Fenelon, C.
    McKenna, J.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (04) : 503 - 506
  • [4] Biomechanical analysis of locking plates for fixation of metacarpal shaft fractures: A finite element analysis
    Zhang, Jian-Feng
    Li, Yong
    Huo, Yong-Xin
    Yan, Ming
    Liang, Shou-Lei
    Wang, Lei
    Wang, Bao-Cang
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2022, 108 (08)
  • [5] Are locking plates better than non-locking plates for treating distal tibial fractures?
    Bastias, Christian
    Henriquez, Hugo
    Pellegrini, Manuel
    Rammelt, Stefan
    Cuchacovich, Natalio
    Lagos, Leonardo
    Carcuro, Giovanni
    FOOT AND ANKLE SURGERY, 2014, 20 (02) : 115 - 119
  • [6] Minimally Invasive Treatment of Distal Tibial Fractures with Locking and Non-Locking Plates
    Ozkaya, Ufuk
    Parmaksizoglu, Atilla S.
    Gul, Murat
    Sokucu, Sami
    Kabukcuoglu, Yavuz
    FOOT & ANKLE INTERNATIONAL, 2009, 30 (12) : 1161 - 1167
  • [7] Locking versus non-locking plate fixation in the management of mandibular fractures: a meta-analysis
    Chrcanovic, B. R.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2014, 43 (10) : 1243 - 1250
  • [8] A Biomechanical Comparison of Locked Unicortical with Non-Locking Bicortical Screws for Metacarpal Shaft Fractures in a Randomized Human Cadaveric Model
    Minogue, Febe
    Reilly, Keryn
    Walker, Cameron
    Malak, Sharif
    Mayo, Andrew
    Heiss-Dunlop, Wolfgang
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2021, 26 (01) : 10 - 16
  • [9] Locking versus non-locking plates in fixation of extra-articular distal humerus fracture: a randomized controlled study
    Galal, Sherif
    Mattar, Yasser
    Solyman, Alaa Mohy Eldin
    Ezzat, Mostafa
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (12) : 2761 - 2767
  • [10] A comparison of bone union and complication rates between locking and non-locking plates in distal fibular fracture: Retrospective study of 106 cases
    El Fatayri, Bachar
    Bulaid, Yassine
    Djebara, Az-Eddine
    Havet, Eric
    Mertl, Patrice
    Dehl, Massinissa
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (12): : 2324 - 2331