The predictors of endoleaks after endovascular repair of experimentally produced fusiform carotid aneurysm in canine

被引:2
作者
Shi, Wan-Yin [1 ]
Gu, Jian-Ping [1 ]
Li, Ming-Hua [2 ]
Yan, Lei [2 ]
He, Xu [1 ]
机构
[1] Nanjing Med Univ, Nanjing Hosp 1, Dept Intervent Radiol, Nanjing, Jiangsu, Peoples R China
[2] Shanghai Jiao Tong Univ, Affiliated Peoples Hosp 6, Dept Diagnost & Intervent Radiol, 600 Yishan Rd, Shanghai 200030, Peoples R China
关键词
fusiform aneurysm; endoleak; covered stent; Animal model; carotid artery; WILLIS COVERED STENT; MIDTERM FOLLOW-UP; MULTICENTER EXPERIENCE; INTRACRANIAL ANEURYSMS; DISSECTING ANEURYSMS; ARTERY; MODEL; OCCLUSION; PSEUDOANEURYSMS; CIRCULATION;
D O I
10.3109/13645706.2015.1092451
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Endoleaks constitute the main concern regarding the use of covered stents in the treatment of intracranial aneurysms. We investigated immediate/late endoleaks after stent-graft placement for the treatment of experimentally created carotid fusiform aneurysm (FA) in a canine model. Material and methods: Eighteen carotid FAs in nine dogs receiving covered stents were followed. Their procedural and angiographic data were collected immediately and six months after stenting. Univariate analysis and multivariate logistic regression analysis were performed to determine the factors predictive of immediate/late endoleaks. Receiver operating characteristic curve analysis was performed to determine the best cutoff values of the independent factors. Results: All carotid FAs were successfully treated with Willis covered stents and received a six-month follow-up. The rate of immediate and late endoleaks after stenting was 38.89% and 16.67%, respectively. Anchoring length was identified as independent predictor of immediate endoleaks (P =0.037) and its best cutoff value was 3.06mm (95% confidence interval: 2.39-3.72). No parameters were identified to be independent predictors of late endoleaks. Conclusions: Treating carotid FAs with Willis covered stents is technically feasible. Most endoleaks heal spontaneously and significantly correlate with anchoring length.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 28 条
[1]   Testing Flow Diverters in Giant Fusiform Aneurysms: A New Experimental Model Can Show Leaks Responsible for Failures [J].
Darsaut, T. E. ;
Bing, F. ;
Salazkin, I. ;
Gevry, G. ;
Raymond, J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (11) :2175-2179
[2]  
Geremia G, 2000, AM J NEURORADIOL, V21, P739
[3]  
Hoit DA, 2008, NEUROSURGERY, V62, P380, DOI [10.1227/01.NEU.0000297138.40345.25, 10.1227/01.NEU.0000335088.85470.FC]
[4]   INFARCTS IN THE ANTERIOR CHOROIDAL ARTERY TERRITORY - ANATOMICAL DISTRIBUTION, CLINICAL SYNDROMES, PRESUMED PATHOGENESIS AND EARLY OUTCOME [J].
HUPPERTS, RMM ;
LODDER, J ;
HEUTSVANRAAK, EPM ;
KESSELS, F .
BRAIN, 1994, 117 :825-834
[5]   Effect of carotid artery stenting on ocular circulation and chronic ocular ischemic syndrome [J].
Kawaguchi, Shoichiro ;
Sakaki, Toshisuke ;
Iwahashi, Hideaki ;
Fujimoto, Kenta ;
Iida, Jun-ichi ;
Mishima, Hideaki ;
Nishikawa, Norikiyo .
CEREBROVASCULAR DISEASES, 2006, 22 (5-6) :402-408
[6]   Very Late Thrombosis of Flow-Diverting Constructs after the Treatment of Large Fusiform Posterior Circulation Aneurysms [J].
Klisch, J. ;
Turk, A. ;
Turner, R. ;
Woo, H. H. ;
Fiorella, D. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (04) :627-632
[7]   Intra-Aneurysmal Thrombosis as a Possible Cause of Delayed Aneurysm Rupture after Flow-Diversion Treatment [J].
Kulcsar, Z. ;
Houdart, E. ;
Bonafe, A. ;
Parker, G. ;
Millar, J. ;
Goddard, A. J. P. ;
Renowden, S. ;
Gal, G. ;
Turowski, B. ;
Mitchell, K. ;
Gray, F. ;
Rodriguez, M. ;
van den Berg, R. ;
Gruber, A. ;
Desal, H. ;
Wanke, I. ;
Ruefenacht, D. A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) :20-25
[8]   Predictors of in-stent stenosis and occlusion after endovascular treatment of intracranial vascular disease with the Willis covered stent [J].
Lai, Xiao-Biao ;
Li, Ming-Hua ;
Tan, Hua-Qiao ;
Luo, Ben-Yan ;
Zhu, Yue-Qi ;
Wang, Jue ;
Li, Yong-Dong .
JOURNAL OF CLINICAL NEUROSCIENCE, 2013, 20 (01) :122-127
[9]  
Leibowitz R, 2003, AM J NEURORADIOL, V24, P902
[10]   A new covered Stent designed for intracranial vasculature: Application in the management of pseudoaneurysms of the cranial internal carotid artery [J].
Li, M.-H. ;
Li, Y.-D. ;
Gao, B.-L. ;
Fang, C. ;
Luo, Q.-Y. ;
Cheng, Y.-S. ;
Xie, Z.-Y. ;
Wang, Y.-L. ;
Zhao, J.-G. ;
Li, Y. ;
Wang, W. ;
Zhang, B. -L. ;
Li, M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (08) :1579-1585