Criteria Revision of Dissolved Gas Analysis for Oil-Filled Transformers in Korea

被引:0
|
作者
Cho, Sung-Min [1 ]
Kim, Jae-Chul [1 ]
机构
[1] Soongsil Univ, Dept Elect Engn, Seoul 156743, South Korea
来源
2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8 | 2009年
关键词
Fault diagnosis; Maintenance; Oil insulation; Power transformers;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The story on revising criteria of Dissolved Gases Analysis (DGA) at KEPCO was introduced. Because of differences in operating environments, construction type, oil volume, and other factors, the interpretative criteria of DGA at KEPCO should be different from other standards such as IEC-60599, or Rogers and Doernenburg. We tried to improve efficiency of DGA by considering accumulated data during twenty-five years. To establish the most appropriate criteria, the DGA results were collected from healthy power transformers as well as transformers which have an incipient fault. The criteria were revised newly using cumulative distribution of concentration of 3,585 healthy power transformers. Although the criteria are revised strictly, work load doesn't increase by controlling analysis interval and condition level.
引用
收藏
页码:4057 / 4060
页数:4
相关论文
共 50 条
  • [21] Optimization of the maintenance of oil filled power transformers based on reliability criteria
    Costa, S
    Brandao, AF
    2004 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: LATIN AMERICA, 2004, : 297 - 301
  • [22] Wavelet Networks in Power Transformers Diagnosis Using Dissolved Gas Analysis
    Chen, Weigen
    Pan, Chong
    Yun, Yuxin
    Liu, Yilu
    IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (01) : 187 - 194
  • [23] A hybrid tool for detection of incipient faults in transformers based on the dissolved gas analysis of insulating oil
    Morais, DR
    Rolim, JG
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (02) : 673 - 680
  • [24] Gas-in-oil analysis and evaluation criteria for synthetic esters in offshore and traction transformers
    Atanasova-Hoehlein, Ivanka
    Schuett, Carolin
    IEEE ELECTRICAL INSULATION MAGAZINE, 2020, 36 (06) : 31 - 35
  • [25] Proposed three ratios technique for the interpretation of mineral oil transformers based dissolved gas analysis
    Gouda, Osama E.
    El-Hoshy, Salah H.
    L-Tamaly, Hassan H. E.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (11) : 2650 - 2661
  • [26] State of the Art of Dissolved Gas Analysis in Power Transformers
    Sarria-Arias, Johana Tatiana
    -Bello, Natalia Andrea Guerrero
    Rivas-Trujillo, Edwin
    REVISTA FACULTAD DE INGENIERIA, UNIVERSIDAD PEDAGOGICA Y TECNOLOGICA DE COLOMBIA, 2014, 23 (36): : 105 - 122
  • [27] Application of Logistic Regression Algorithm in the Interpretation of Dissolved Gas Analysis for Power Transformers
    Almoallem, Yousuf D.
    Taha, Ibrahim B. M.
    Mosaad, Mohamed I.
    Nahma, Lara
    Abu-Siada, Ahmed
    ELECTRONICS, 2021, 10 (10)
  • [28] Recognition of low-temperature overheating in power transformers by dissolved gas analysis
    Shutenko, Oleg
    Kulyk, Oleksii
    ELECTRICAL ENGINEERING, 2022, 104 (04) : 2109 - 2121
  • [29] Predictive Modelingof Dissolved Gas Concentrationin Oil-Immersed Substation Transformers
    Kim, Younghun
    Goyal, Aanchal
    Kumar, Tarun
    2016 THE 4TH IEEE INTERNATIONAL CONFERENCE ON SMART ENERGY GRID ENGINEERING (SEGE), 2016, : 261 - 267
  • [30] Voltage-time and voltage-number characteristics of insulation elements with oil-filled transformers in EHV and UHV classes
    Okabe, S
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2006, 13 (02) : 436 - 444