Polydimethylsiloxane/covalent triazine frameworks coated stir bar sorptive extraction coupled with high performance liquid chromatography-ultraviolet detection for the determination of phenols in environmental water samples

被引:99
作者
Zhong, Cheng [1 ]
He, Man [1 ]
Liao, Huaping [1 ]
Chen, Beibei [1 ]
Wang, Cheng [1 ]
Hu, Bin [1 ]
机构
[1] Wuhan Univ, Dept Chem, Minist Educ, Key Lab Analyt Chem Biol & Med, Wuhan 430072, Peoples R China
关键词
Polydimethylsiloxane/covalent triazine frameworks; Stir bar sorptive extraction; High performance liquid; chromatography-ultraviolet detector; Phenols; Environmental water samples; SOLID-PHASE MICROEXTRACTION; WALLED CARBON NANOTUBES; MASS SPECTROMETRY; AQUEOUS SAMPLES; SINGLE-DROP; CHLOROPHENOLS; FIBER; POLAR; LAKE;
D O I
10.1016/j.chroma.2016.02.073
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, covalent triazine frameworks (CTFs) were introduced in stir bar sorptive extraction (SBSE) and a novel polydimethylsiloxane(PDMS)/CTFs stir bar coating was prepared by sol-gel technique for the sorptive extraction of eight phenols (including phenol, 2-chlorophenol, 2-nitrophenol, 4-nitrophenol, 2,4-dimethylphenol, p-chloro-m-cresol and 2,4-dichlorophenol, 2,4,6-trichlorophenol) from environmental water samples followed by high performance liquid chromatography-ultraviolet (HPLC-UV) detection. The prepared PDMS/CTFs coated stir bar showed good preparation reproducibility with the relative standard deviations (RSDs) ranging from 3.5 to 5.7% (n = 7) in one batch, and from 3.7 to 9.3% (n = 7) among different batches. Several parameters affecting SBSE of eight target phenols including extraction time, stirring rate, sample pH, ionic strength, desorption solvent and desorption time were investigated. Under the optimal experimental conditions, the limits of detection (LODs, S/N = 3) were found to be in the range of 0.08-0.30 mu g/L. The linear range was 0.25-500 mu g/L for 2-nitrophenol, 0.5-500 mu g/L for phenol, 2-chlorophenol, 4-nitrophenol as well as 2,4-dimethylphenol, and 1-500 mu g/L for p-chloro-m-cresol, 2,4-dichlorophenol as well as 2,4,6-trichlorophenol, respectively. The intra-day relative standard deviations (RSDs) were in the range of 4.3-9.4% (n = 7, c = 2 mu g/L) and the enrichment factors ranged from 64.9 to 145.6 fold (theoretical enrichment factor was 200-fold). Compared with commercial PDMS coated stir bar (Gerstel) and PEG coated stir bar (Gerstel), the prepared PDMS/CTFs stir bar showed better extraction efficiency for target phenol compounds. The proposed method was successfully applied to the analysis of phenols in environmental water samples and good relative recoveries were obtained with the spiking level at 2, 10, 50 mu g/L, respectively. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:8 / 15
页数:8
相关论文
共 32 条
[1]   A novel sol-gel-based amino-functionalized fiber for headspace solid-phase microextraction of phenol and chlorophenols from environmental samples [J].
Bagheri, Habib ;
Babanezhad, Esmaeil ;
Khalilian, Faezeh .
ANALYTICA CHIMICA ACTA, 2008, 616 (01) :49-55
[2]   Sorptive sample preparation - a review [J].
Baltussen, E ;
Cramers, CA ;
Sandra, PJF .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (1-2) :3-22
[3]  
Baltussen E, 1999, J MICROCOLUMN SEP, V11, P737, DOI 10.1002/(SICI)1520-667X(1999)11:10<737::AID-MCS7>3.0.CO
[4]  
2-4
[5]   High adsorptive properties of covalent triazine-based frameworks (CTFs) for surfactants from aqueous solution [J].
Bhunia, Asamanjoy ;
Dey, Subarna ;
Bous, Maria ;
Zhang, Chenyang ;
von Rybinski, Wolfgang ;
Janiak, Christoph .
CHEMICAL COMMUNICATIONS, 2015, 51 (03) :484-486
[6]   Stir bar sorptive extraction coupled to gas chromatography-mass spectrometry for the determination of bisphenols in canned beverages and filling liquids of canned vegetables [J].
Cacho, J. I. ;
Campillo, N. ;
Vinas, P. ;
Hernandez-Cordoba, M. .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1247 :146-153
[7]   Multi-walled carbon nanotubes as a solid-phase extraction adsorbent for the determination of chlorophenols in environmental water samples [J].
Cai, YQ ;
Cai, YE ;
Mou, SF ;
Lu, YQ .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1081 (02) :245-247
[8]   Stir bar sorptive extraction: Recent applications, limitations and future trends [J].
Camino-Sanchez, F. J. ;
Rodriguez-Gomez, R. ;
Zafra-Gomez, A. ;
Santos-Fandila, A. ;
Vilchez, J. L. .
TALANTA, 2014, 130 :388-399
[9]   Stir bar sorptive extraction coupled to liquid chromatography for the analysis of strobilurin fungicides in fruit samples [J].
Campillo, Natalia ;
Vinas, Pilar ;
Aguinaga, Nerea ;
Ferez, Gema ;
Hernandez-Cordoba, Manuel .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (27) :4529-4534
[10]   Multicomponent sequential injection analysis determination of nitro-phenols in waters by on-line liquid-liquid extraction and preconcentration [J].
Cladera, A ;
Miró, M ;
Estela, JM ;
Cerdà, V .
ANALYTICA CHIMICA ACTA, 2000, 421 (02) :155-166