Long-term variability of GDx VCC retinal nerve fiber layer thickness measurements

被引:20
作者
Medeiros, Felipe A. [1 ]
Doshi, Rishi [1 ]
Zangwill, Linda M. [1 ]
Vasile, Cristiana [1 ]
Weinreb, Robert N. [1 ]
机构
[1] Univ Calif San Diego, Hamilton Glaucoma Ctr, Dept Ophthalmol, La Jolla, CA 92093 USA
关键词
scanning laser polarimetry; reproducibility; glaucoma; nerve fiber layer;
D O I
10.1097/IJG.0b013e3180391a3c
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the long-term variability of GDx VCC retinal nerve fiber layer (RNFL) thickness measurements. Methods: The study enrolled a cohort of glaucoma suspects who did not develop any evidence of visual field damage or change in the appearance of the optic nerve during an average follow-up of 9.1 +/- 3.2 years. Subjects underwent ocular imaging using the commercially available GDx VCC scanning laser polarimeter. At each visit, each eye was imaged 3 times. Subjects underwent repeated testing with GDx VCC at approximately 12-month intervals during their follow-up. In total, 255 examinations were obtained in 31 eyes of 31 individuals during an average GDx VCC follow-up time of 26.0 +/- 8.9 months. A random effects analysis of variance model was used to estimate intraclass correlation coefficients and long-term and short-term variability estimates. Results: Intraclass correlation coefficients ranged from 0.77 to 0.86 for GDx VCC parameters. Short-term variability estimates ranged from 2.45 to 3.89 mu m for RNFL thickness parameters, whereas the short-term variability estimate for the parameter Nerve Fiber Indicator was 3.71. Long-term variability was slightly higher than short-term variability for all parameters. For RNFL thickness parameters, long-term variability estimates ranged from 3.21 to 4.97 mu m, whereas for the parameter Nerve Fiber Indicator the long-term variability estimate was 4.93. Conclusions: RNFL measurements obtained with the GDx VCC were found to be highly reproducible in a long-term test-retest situation, supporting the use of this instrument for longitudinal assessment of the RNFL.
引用
收藏
页码:277 / 281
页数:5
相关论文
共 24 条
[1]   Inter-device reproducibility of the scanning laser polarimeter with variable cornea compensation [J].
Blumenthal, EZ ;
Frenkel, S .
EYE, 2005, 19 (03) :308-311
[2]   Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes [J].
Budenz, DL ;
Chang, RT ;
Huang, XR ;
Knighton, RW ;
Tielsch, JM .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) :2440-2443
[3]  
Chi Q M, 1995, J Glaucoma, V4, P406
[4]  
Colen TP, 2000, J GLAUCOMA, V9, P363
[5]  
Fleiss JL, 2013, STAT METHODS RATES P
[6]   Operator learning effect and interoperator reproducibility of the scanning laser polarimeter with variable corneal compensation [J].
Frenkel, S ;
Slonim, E ;
Horani, A ;
Molcho, M ;
Barzel, I ;
Blumenthal, EZ .
OPHTHALMOLOGY, 2005, 112 (02) :257-261
[7]   Normative retardation data corrected for the corneal polarization axis with scanning laser polarimetry [J].
Greenfield, DS ;
Knighton, RW ;
Feuer, WJ ;
Schiffman, JC .
OPHTHALMIC SURGERY LASERS & IMAGING, 2003, 34 (02) :165-171
[8]  
Hoh ST, 1998, J GLAUCOMA, V7, P12
[9]   Intersession reproducibility of retinal nerve fiber layer thickness measurements by GDx-VCC in healthy and glaucomatous eyes [J].
Iacono, Pierluigi ;
Da Pozzo, Stefano ;
Fuser, Mirko ;
Marchesan, Roberta ;
Ravalico, Giuseppe .
OPHTHALMOLOGICA, 2006, 220 (04) :266-271
[10]   Reproducibility of the data determined by scanning laser polarimetry [J].
Junghardt, A ;
Schmid, MK ;
Schipper, I ;
Wildberger, H ;
Seifert, B .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1996, 234 (10) :628-632