Flow injection system for the on-line preconcentration of Pb by cloud point extraction coupled to USN-ICP OES

被引:34
作者
Gil, Raul A. [1 ]
Salonia, Jose A. [1 ]
Gasquez, Jose A. [1 ]
Olivieri, Alejandro C. [2 ]
Olsina, Roberto [1 ]
Martinez, Luis D. [1 ]
机构
[1] INQUISAL UNSL CONICET, Inst Quim San Luis, Chacabuco Y Pedernera, San Luis, Argentina
[2] Univ Nacl Rosario, Fac Ciencias Bioquim & Farmaceut, Dept Quim Analit, UNR Suipacha, Santa Fe, Argentina
关键词
Pb determination; On-line cloud point extraction; PTFE-minicolumn; Drinking water; USN-ICP OES; ATOMIC-ABSORPTION-SPECTROMETRY; OPTICAL-EMISSION-SPECTROMETRY; NONIONIC SURFACTANTS; METAL ANALYSIS; SEPARATION; SAMPLES; SPECIATION; URINE; LEAD;
D O I
10.1016/j.microc.2010.01.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method for the determination of Pb by on-line cloud point extraction coupled to inductively coupled plasma optical emission spectrometry with ultrasonic nebulization (USN-ICP OES) is presented The cloud point system was formed in the presence of non-ionic micelles of polyethyleneglycolmono-p-nonylphenyether (PONPE 7 5) and was retained in a minicolumn filled with particles of PTFE. Since the micelles of PONPE were able to extract Pb from the solutions, the use of a complexing reagent was not necessary Afterwards, the surfactant-rich phase containing the analyte was removed from the minicolumn with nitric acid and introduced into the ultrasonic nebulizer. A total enhancement factor of 150 was obtained for a preconcentration time of 3 3 min, with respect to the direct determination of Pb by conventional ICP OES The values of the detection (3 sigma) and quantification (10 sigma) limits for the preconcentration of 10 mL of sample solution were 009 mu g L(-1) and 02 mu g L(-1) respectively The precision, expressed as the relative standard deviation (RSD), for 10 replicate determinations at 50 mu g L(-1) Pb level was 6.0% Verification of the accuracy was carried out by analysis of two certified reference materials (NIST SRM 1640e and VKI QC Metal LL1) The method was successfully applied to the determination of Pb in drinking water samples (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:306 / 310
页数:5
相关论文
共 25 条
[1]  
Bratter P., 1980, Trace elements in analytical chemistry
[2]  
FANG ZL, 1995, FLOW INJECTION ATOMI
[3]   Coupling cloud point extraction to instrumental detection systems for metal analysis [J].
Fernanda Silva, Maria ;
Soledad Cerutti, Estela ;
Martinez, Luis D. .
MICROCHIMICA ACTA, 2006, 155 (3-4) :349-364
[4]   The use of micellar systems in the extraction and pre-concentration of organic pollutants in environmental samples [J].
Ferrera, ZS ;
Sanz, CP ;
Santana, CM ;
Rodríguez, JJS .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2004, 23 (07) :469-479
[5]   Cloud point extraction for cobalt preconcentration with on-line phase separation in a knotted reactor followed by ETAAS determination in drinking waters [J].
Gil, Raul A. ;
Gasquez, Jose A. ;
Olsina, Roberto ;
Martinez, Luis D. ;
Cerutti, Soledad .
TALANTA, 2008, 76 (03) :669-673
[6]  
HIDRICAS B, 2009, AGUA AGUA GASIFICADA, pCH12
[7]   A CRITICAL-REVIEW OF SURFACTANT-MEDIATED PHASE SEPARATIONS (CLOUD-POINT EXTRACTIONS) - THEORY AND APPLICATIONS [J].
HINZE, WL ;
PRAMAURO, E .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1993, 24 (02) :133-177
[8]   Separation and preconcentration procedures for the determination of lead using spectrometric techniques: A review [J].
Korn, MDA ;
de Andrade, JB ;
de Jesus, DS ;
Lemos, VA ;
Bandeira, MLSF ;
dos Santos, WNL ;
Bezerra, MA ;
Amorim, FAC ;
Souza, AS ;
Ferreira, SLC .
TALANTA, 2006, 69 (01) :16-24
[9]   An on-line cloud point extraction system for flame atomic absorption spectrometric determination of trace manganese in food samples [J].
Lemos, Valfredo Azevedo ;
David, Graciete Teixeira .
MICROCHEMICAL JOURNAL, 2010, 94 (01) :42-47
[10]   On-line cloud point extraction combined with electrothermal vaporization inductively coupled plasma atomic emission spectrometry for the speciation of inorganic antimony in environmental and biological samples [J].
Li, Yingjie ;
Hu, Bin ;
Jiang, Zucheng .
ANALYTICA CHIMICA ACTA, 2006, 576 (02) :207-214