Analysis of Wearable and Smartphone-Based Technologies for the Measurement of Barbell Velocity in Different Resistance Training Exercises

被引:87
作者
Balsalobre-Fernandez, Carlos [1 ,2 ]
Marchante, David [2 ]
Baz-Valle, Eneko [2 ]
Alonso-Molero, Ivan [2 ]
Jimenez, Sergio L. [1 ]
Munoz-Lopez, Mario [2 ]
机构
[1] European Univ Madrid, Sch Sports Sci, Madrid, Spain
[2] PowerExplos Ctr, Dept Res & Dev, Madrid, Spain
关键词
monitoring; biomechanics; technology; strength; validation; MOVEMENT VELOCITY; PREDICTION; STRENGTH; POWER; LOAD; RELIABILITY; PERFORMANCE; ADAPTATIONS; INTENSITY; VALIDITY;
D O I
10.3389/fphys.2017.00649
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The purpose of this study was to analyze the validity, reliability, and accuracy of new wearable and smartphone-based technology for the measurement of barbell velocity in resistance training exercises. To do this, 10 highly trained powerlifters (age = 26.1 +/- 3.9 years) performed 11 repetitions with loads ranging 50-100% of the 1-Repetition maximum in the bench-press, full-squat, and hip-thrust exercises while barbell velocity was simultaneously measured using a linear transducer (LT), two Beast wearable devices (one placed on the subjects' wrist -BW-, and the other one directly attached to the barbell -BB-) and the iOS PowerLift app. Results showed a high correlation between the LT and BW (r = 0.94-0.98, SEE = 0.04-0.07 m.s(-1)), BB (r = 0.97-0.98, SEE = 0.04-0.05 m.s(-1)), and the PowerLift app (r = 0.97-0.98, SEE = 0.03-0.05 m.s(-1)) for the measurement of barbell velocity in the three exercises. Paired samples T-test revealed systematic biases between the LT and BW, BB and the app in the hip-thrust, between the LT and BW in the full-squat and between the LT and BB in the bench-press exercise (p < 0.001). Moreover, the analysis of the linear regression on the Bland-Altman plots showed that the differences between the LT and BW (R-2 = 0.004-0.03), BB (R-2 = 0.007-0.01), and the app (R-2 = 0.001-0.03) were similar across the whole range of velocities analyzed. Finally, the reliability of the BW (ICC = 0.910-0.988), BB (ICC = 0.922-0.990), and the app (ICC = 0.928-0.989) for the measurement of the two repetitions performed with each load were almost the same than that observed with the LT (ICC = 0.937-0.990). Both the Beast wearable device and the PowerLift app were highly valid, reliable, and accurate for the measurement of barbell velocity in the bench-press, full-squat, and hip-thrust exercises. These results could have potential practical applications for strength and conditioning coaches who wish to measure barbell velocity during resistance training.
引用
收藏
页数:10
相关论文
共 29 条
[1]   The Validity and Reliability of an iPhone App for Measuring Running Mechanics [J].
Balsalobre-Fernandez, Carlos ;
Agopyan, Hovannes ;
Morin, Jean-Benoit .
JOURNAL OF APPLIED BIOMECHANICS, 2017, 33 (03) :222-226
[2]   Validity and reliability of a novel iPhone app for the measurement of barbell velocity and 1RM on the bench-press exercise [J].
Balsalobre-Fernandez, Carlos ;
Marchante, David ;
Munoz-Lopez, Mario ;
Jimenez, Sergio L. .
JOURNAL OF SPORTS SCIENCES, 2018, 36 (01) :64-70
[3]   VALIDITY AND RELIABILITY OF THE PUSH WEARABLE DEVICE TO MEASURE MOVEMENT VELOCITY DURING THE BACK SQUAT EXERCISE [J].
Balsalobre-Fernandez, Carlos ;
Kuzdub, Matt ;
Poveda-Ortiz, Pedro ;
del Campo-Vecino, Juan .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2016, 30 (07) :1968-1974
[4]   The validity and reliability of an iPhone app for measuring vertical jump performance [J].
Balsalobre-Fernandez, Carlos ;
Glaister, Mark ;
Lockey, Richard Anthony .
JOURNAL OF SPORTS SCIENCES, 2015, 33 (15) :1574-1579
[5]   Validity of Various Methods for Determining Velocity, Force, and Power in the Back Squat [J].
Banyard, Harry G. ;
Nosaka, Ken ;
Sato, Kimitake ;
Haff, G. Gregory .
INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2017, 12 (09) :1170-1176
[6]   RELIABILITY AND VALIDITY OF THE LOAD-VELOCITY RELATIONSHIP TO PREDICT THE 1RM BACK SQUAT [J].
Banyard, Harry G. ;
Nosaka, Kazunori ;
Haff, G. Gregory .
JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2017, 31 (07) :1897-1904
[7]   The Quantification of Training Load, the Training Response and the Effect on Performance [J].
Borresen, Jill ;
Lambert, Michael Ian .
SPORTS MEDICINE, 2009, 39 (09) :779-795
[8]   Determining Strength: A Case for Multiple Methods of Measurement [J].
Buckner, Samuel L. ;
Jessee, Matthew B. ;
Mattocks, Kevin T. ;
Mouser, J. Grant ;
Counts, Brittany R. ;
Dankel, Scott J. ;
Loenneke, Jeremy P. .
SPORTS MEDICINE, 2017, 47 (02) :193-195
[9]   Movement velocity as a measure of exercise intensity in three lower limb exercises [J].
Conceicao, Filipe ;
Fernandes, Juvenal ;
Lewis, Martin ;
Gonzalez-Badillo, Juan Jose ;
Jimenez-Reyes, Pedro .
JOURNAL OF SPORTS SCIENCES, 2016, 34 (12) :1099-1106
[10]   The adaptations to strength training - Morphological and neurological contributions to increased strength [J].
Folland, Jonathan P. ;
Williams, Alun G. .