Impact of prosthetic mitral valve orientation on the ventricular flow field: Comparison using patient-specific computational fluid dynamics

被引:17
|
作者
Lantz, Jonas [1 ,2 ]
Back, Sophia [1 ,2 ]
Carlhall, Carl-Johan [2 ,3 ,4 ]
Bolger, Ann [3 ,4 ,5 ]
Persson, Anders [2 ,6 ]
Karlsson, Matts [2 ,7 ]
Ebbers, Tino [1 ,2 ]
机构
[1] Linkoping Univ, Dept Hlth Med & Caring Sci, Div Cardiovasc Med, Linkoping, Sweden
[2] Linkoping Univ, Ctr Med Image Sci & Visualizat CMIV, Linkoping, Sweden
[3] Linkoping Univ, Dept Clin Physiol Linkoping, Linkoping, Sweden
[4] Linkoping Univ, Dept Hlth Med & Caring Sci, SE-58183 Linkoping, Sweden
[5] Univ Calif San Francisco, Dept Med, San Francisco, CA 94143 USA
[6] Linkoping Univ, Dept Hlth Med & Caring Sci, Div Radiol, Linkoping, Sweden
[7] Linkoping Univ, Dept Management & Engn, Div Appl Thermodynam & Fluid Mech, Linkoping, Sweden
基金
瑞典研究理事会;
关键词
Computational fluid dynamics; Virtual implantation; Mitral valve; Computed tomography; 4D flow CT;
D O I
10.1016/j.jbiomech.2020.110209
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Significant mitral valve regurgitation creates progressive adverse remodeling of the left ventricle (LV). Replacement of the failing valve with a prosthesis generally improves patient outcomes but leaves the patient with non-physiological intracardiac flow patterns that might contribute to their future risk of thrombus formation and embolism. It has been suggested that the angular orientation of the implanted valve might modify the postoperative distortion of the intraventricular flow field. In this study, we investigated the effect of prosthetic valve orientation on LV flow patterns by using heart geometry from a patient with LV dysfunction and a competent native mitral valve to calculate intracardiac flow fields with computational fluid dynamics (CFD). Results were validated using in vivo 4D Flow MRI. The computed flow fields were compared to calculations following virtual implantation of a mechanical heart valve oriented in four different angles to assess the effect of leaflet position. Flow patterns were visualized in longand short-axes and quantified with flow component analysis. In comparison to a native valve, valve implantation increased the proportion of the mitral inflow remaining in the basal region and further increased the residual volume in the apical area. Only slight changes due to valve orientation were observed. Using our numerical framework, we demonstrated quantitative changes in left ventricular blood flow due to prosthetic mitral replacement. This framework may be used to improve design of prosthetic heart valves and implantation procedures to minimize the potential for apical flow stasis, and potentially assist personalized treatment planning. (c) 2020 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Size-Dependent Distribution of Patient-Specific Hemodynamic Factors in Unruptured Cerebral Aneurysms Using Computational Fluid Dynamics
    Lee, Ui Yun
    Chung, Gyung Ho
    Jung, Jinmu
    Kwak, Hyo Sung
    DIAGNOSTICS, 2020, 10 (02)
  • [22] Numerical simulation and analysis of excited rotary valve flow field with computational fluid dynamics
    Yu-ning, Song
    Guochao, Zhao
    Peng, Fu
    JOURNAL OF ENGINEERING-JOE, 2020, 2020 (14): : 1037 - 1039
  • [23] Analysis of fluid flow through a bidirectional cone throttle valve using computational fluid dynamics
    Sang, Yong
    Wang, Xudong
    Sun, Weiqi
    AUSTRALIAN JOURNAL OF MECHANICAL ENGINEERING, 2021, 19 (01) : 71 - 80
  • [24] ESTIMATION OF PATIENT-SPECIFIC MATERIAL PROPERTIES OF THE MITRAL VALVE USING 4D TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    Kanik, Jingjing
    Mansi, Tommaso
    Voigt, Ingmar
    Sharma, Puneet
    Ionasec, Razvan Ioan
    Comaniciu, Dorin
    Duncan, James
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 1178 - 1181
  • [25] Patient-specific computational fluid dynamics analysis of transcatheter aortic root replacement with chimney coronary grafts
    Conti, Michele
    Romarowski, Rodrigo M.
    Ferrarini, Anna
    Stochino, Matteo
    Auricchio, Ferdinando
    Morganti, Simone
    von Segesser, Ludwig Karl
    Ferrari, Enrico
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2021, 32 (03) : 408 - 416
  • [26] A Patient-Specific Computational Fluid Dynamics Model of the Left Atrium in Atrial Fibrillation: Development and Initial Evaluation
    Masci, Alessandro
    Alessandrini, Martino
    Forti, Davide
    Menghini, Filippo
    Dede, Luca
    Tommasi, Corrado
    Quarteroni, Alfio
    Corsi, Cristiana
    FUNCTIONAL IMAGING AND MODELLING OF THE HEART, 2017, 10263 : 392 - 400
  • [27] Effects of Microporous Stent Graft on the Descending Aortic Aneurysm: A Patient-Specific Computational Fluid Dynamics Study
    Ong, Chi-Wei
    Ho, Pei
    Leo, Hwa-Liang
    ARTIFICIAL ORGANS, 2016, 40 (11) : E230 - E240
  • [28] Elevated atrial blood stasis in paroxysmal atrial fibrillation during sinus rhythm: a patient-specific computational fluid dynamics study
    Back, Sophia
    Skoda, Iulia
    Lantz, Jonas
    Henriksson, Lilian
    Karlsson, Lars O.
    Persson, Anders
    Carlhall, Carl-Johan
    Ebbers, Tino
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [29] Multiscale, patient-specific computational fluid dynamics models predict formation of neointimal hyperplasia in saphenous vein grafts
    Donadoni, Francesca
    Pichardo-Almarza, Cesar
    Homer-Vanniasinkam, Shervanthi
    Dardik, Alan
    Diaz-Zuccarini, Vanessa
    JOURNAL OF VASCULAR SURGERY CASES AND INNOVATIVE TECHNIQUES, 2020, 6 (02): : 292 - 306
  • [30] Patient-Specific Computational Fluid Dynamics in Ruptured Posterior Communicating Aneurysms Using Measured Non-Newtonian Viscosity : A Preliminary Study
    Lee, Ui Yun
    Jung, Jinmu
    Kwak, Hyo Sung
    Lee, Dong Hwan
    Chung, Gyung Ho
    Park, Jung Soo
    Koh, Eun Jeong
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2019, 62 (02) : 183 - 192