Impact of prosthetic mitral valve orientation on the ventricular flow field: Comparison using patient-specific computational fluid dynamics

被引:17
|
作者
Lantz, Jonas [1 ,2 ]
Back, Sophia [1 ,2 ]
Carlhall, Carl-Johan [2 ,3 ,4 ]
Bolger, Ann [3 ,4 ,5 ]
Persson, Anders [2 ,6 ]
Karlsson, Matts [2 ,7 ]
Ebbers, Tino [1 ,2 ]
机构
[1] Linkoping Univ, Dept Hlth Med & Caring Sci, Div Cardiovasc Med, Linkoping, Sweden
[2] Linkoping Univ, Ctr Med Image Sci & Visualizat CMIV, Linkoping, Sweden
[3] Linkoping Univ, Dept Clin Physiol Linkoping, Linkoping, Sweden
[4] Linkoping Univ, Dept Hlth Med & Caring Sci, SE-58183 Linkoping, Sweden
[5] Univ Calif San Francisco, Dept Med, San Francisco, CA 94143 USA
[6] Linkoping Univ, Dept Hlth Med & Caring Sci, Div Radiol, Linkoping, Sweden
[7] Linkoping Univ, Dept Management & Engn, Div Appl Thermodynam & Fluid Mech, Linkoping, Sweden
基金
瑞典研究理事会;
关键词
Computational fluid dynamics; Virtual implantation; Mitral valve; Computed tomography; 4D flow CT;
D O I
10.1016/j.jbiomech.2020.110209
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Significant mitral valve regurgitation creates progressive adverse remodeling of the left ventricle (LV). Replacement of the failing valve with a prosthesis generally improves patient outcomes but leaves the patient with non-physiological intracardiac flow patterns that might contribute to their future risk of thrombus formation and embolism. It has been suggested that the angular orientation of the implanted valve might modify the postoperative distortion of the intraventricular flow field. In this study, we investigated the effect of prosthetic valve orientation on LV flow patterns by using heart geometry from a patient with LV dysfunction and a competent native mitral valve to calculate intracardiac flow fields with computational fluid dynamics (CFD). Results were validated using in vivo 4D Flow MRI. The computed flow fields were compared to calculations following virtual implantation of a mechanical heart valve oriented in four different angles to assess the effect of leaflet position. Flow patterns were visualized in longand short-axes and quantified with flow component analysis. In comparison to a native valve, valve implantation increased the proportion of the mitral inflow remaining in the basal region and further increased the residual volume in the apical area. Only slight changes due to valve orientation were observed. Using our numerical framework, we demonstrated quantitative changes in left ventricular blood flow due to prosthetic mitral replacement. This framework may be used to improve design of prosthetic heart valves and implantation procedures to minimize the potential for apical flow stasis, and potentially assist personalized treatment planning. (c) 2020 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Patient-specific computational fluid dynamics for hypertrophic obstructive cardiomyopathy
    Hou, Quanfei
    Wu, Wenqian
    Fang, Lingyun
    Zhang, Xin
    Sun, Chenchen
    Ji, Li
    Yang, Ming
    Lei, Ziqiao
    Gao, Fan
    Wang, Jing
    Xie, Mingxing
    Chen, Shu
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2023, 389
  • [2] A comparison of estimation methods for computational fluid dynamics outflow boundary conditions using patient-specific carotid artery
    Lee, Chang-Joon
    Uemiya, Nahoko
    Ishihara, Shoichiro
    Zhang, Yu
    Qian, Yi
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H6) : 663 - 671
  • [3] Patient-Specific Three-Dimensional Ultrasound Derived Computational Modeling of the Mitral Valve
    Gaidulis, Gediminas
    Suresh, Kirthana Sreerangathama
    Xu, Dongyang
    Padala, Muralidhar
    ANNALS OF BIOMEDICAL ENGINEERING, 2022, 50 (07) : 847 - 859
  • [4] FSI Modeling of Prosthetic Mitral Valve Dynamics and Left Ventricular Flow during Diastole
    Su Boyang
    Zhong Liang
    Cui Fangsen
    Praveen, Kumar Gideon
    Phang Hui Qun
    Jimmy, Hon Kim Fatt
    Liang, Leo Hwa
    2013 39TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC 2013), 2013, : 57 - +
  • [5] COMPUTATIONAL FLUID DYNAMICS OF TWO PATIENT-SPECIFIC SYSTEMIC TO PULMONARY SHUNTS
    Ding, Jinli
    Liu, Youjun
    Chai, Linjuan
    Cao, Xue
    Wang, Feng
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2013, 13 (01)
  • [6] MANUFACTURING AND COMPUTATIONAL FLUID DYNAMICS MODELING OF A PATIENT-SPECIFIC FISTULA MODEL
    Liu, Yang
    Zheng, Yihao
    Pitre, John
    Weitzel, William
    Bull, Joseph
    Shih, Albert
    PROCEEDINGS OF THE ASME 12TH INTERNATIONAL MANUFACTURING SCIENCE AND ENGINEERING CONFERENCE - 2017, VOL 4, 2017,
  • [7] Patient-specific computational fluid dynamic simulation of cerebrospinal fluid flow in the intracranial space
    Fillingham, Patrick
    Levendovszky, Swati Rane
    Andre, Jalal
    Parsey, Carolyn
    Bindschadler, Michael
    Friedman, Seth
    Kurt, Mehmet
    Aliseda, Alberto
    Levitt, Michael R.
    BRAIN RESEARCH, 2022, 1790
  • [8] Leveraging Patient-Specific Simulated Angiograms to Characterize Cerebral Aneurysm Hemodynamics using Computational Fluid Dynamics
    Chivukula, V
    White, R.
    Shields, A.
    Davies, J.
    Mokin, M.
    Bednarek, D. R.
    Rudin, S.
    Ionita, C.
    MEDICAL IMAGING 2022: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2022, 12036
  • [9] Patient-Specific Characterization of Breast Cancer Hemodynamics Using Image-Guided Computational Fluid Dynamics
    Wu, Chengyue
    Hormuth, David A.
    Oliver, Todd A.
    Pineda, Federico
    Lorenzo, Guillermo
    Karczmar, Gregory S.
    Moser, Robert D.
    Yankeelov, Thomas E.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (09) : 2760 - 2771
  • [10] Evaluating Design of Abdominal Aortic Aneurysm Endografts in a Patient-Specific Model Using Computational Fluid Dynamics
    Segalova, Polina A.
    Xiong, Guanglei
    Rao, K. T. Venkateswara
    Zarins, Christopher K.
    Taylor, Charles A.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2011, 5 (04):