Overall and local thermal sensation & comfort in air-conditioned dormitory with hot-humid climate

被引:42
作者
He, Yingdong [1 ]
Li, Nianping [1 ]
Zhang, Wenjie [1 ]
Peng, Jinqing [1 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Local thermal sensation; Local thermal comfort; Air-conditioned dormitory; Hot-humid climate; FIELD EXPERIMENTS; UNIVERSITY CLASSROOMS; ENVIRONMENT; CHINA; BUILDINGS; PERCEPTION; STUDENTS; OFFICES; TROPICS; HUMANS;
D O I
10.1016/j.buildenv.2016.02.025
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study aims to investigate students' overall and local thermal sensation & comfort in air-conditioned dormitories of university. A field survey was conducted in air-conditioned dormitories in Changsha, a big city in south of China with hot-humid climate in summer. This survey combined environmental parameters measurements and questionnaires. The obtained results indicated that head exerted the highest influence on overall thermal sensation, followed by calf and foot, then the influences of chest and back were comparatively lower. Such a result can be explained by physiological, environmental and local-disturbed factors. As for overall thermal comfort, it was determined by the most and the second most comfortable body parts. In this study, those two body parts usually went to head and chest. Characteristics of body parts and indoor environment explained the relationship between overall and local thermal comfort. Moreover, in most cases, overall comfort was higher than local comfort of any other body part due to the high-level control over the indoor environment. Nevertheless, because of various factors in real environment, there were significant differences of local thermal sensation among current studies. Therefore, more studies are still in need to establish a more universal model. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:102 / 109
页数:8
相关论文
共 43 条
[31]  
Wang L, 2010, ENERGY ENV, V29, P78
[32]  
Wang L, 2009, REFRIG AIR CONDITION, V23, P36
[33]  
Wang L, 2010, ENERGY ENV, V29, P67
[34]  
Wang L, 2009, REFRIG AIR CONDITION, V23, P44
[35]   Thermal comfort in classrooms in the tropics [J].
Wong, NH ;
Khoo, SS .
ENERGY AND BUILDINGS, 2003, 35 (04) :337-351
[36]  
Xia B., 2006, HV AC, V5, P105
[37]   Occupants' adaptive responses and perception of thermal environment in naturally conditioned university classrooms [J].
Yao, Runming ;
Liu, Jing ;
Li, Baizhan .
APPLIED ENERGY, 2010, 87 (03) :1015-1022
[38]  
Zhang H., 2003, Human thermal sensation and comfort in transient and non-uniform thermal environments
[39]   Thermal sensation and comfort models for non-uniform and transient environments, part III: Whole-body sensation and comfort [J].
Zhang, Hui ;
Arens, Edward ;
Huizenga, Charlie ;
Han, Taeyoung .
BUILDING AND ENVIRONMENT, 2010, 45 (02) :399-410
[40]   Thermal sensation and comfort models for non-uniform and transient environments, part II: Local comfort of individual body parts [J].
Zhang, Hui ;
Arens, Edward ;
Huizenga, Charlie ;
Han, Taeyoung .
BUILDING AND ENVIRONMENT, 2010, 45 (02) :389-398