EXPERIMENTAL INVESTIGATION OF THE 100 keV X-RAY DOSE RESPONSE OF THE HIGH-TEMPERATURE THERMOLUMINESCENCE IN LIF:MG,TI (TLD-100): THEORETICAL INTERPRETATION USING THE UNIFIED INTERACTION MODEL

被引:19
作者
Livingstone, J. [2 ]
Horowitz, Y. S. [1 ]
Oster, L. [3 ]
Datz, H. [4 ]
Lerch, M. [2 ]
Rosenfeld, A. [2 ]
Horowitz, A. [5 ]
机构
[1] Ben Gurion Univ Negev, Dept Phys, IL-84105 Beer Sheva, Israel
[2] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[3] Sami Shamoon Coll Engn, Phys Unit, Beer Sheva, Israel
[4] Soreq Nucl Res Ctr, Radiat Safety Div, IL-70600 Yavne, Israel
[5] Nucl Res Ctr Negev, Crystal Growth Div, IL-84190 Beer Sheva, Israel
关键词
GLOW CURVE; IONIZATION DENSITY; LIF-MG; TI TLD-100; EMISSION-SPECTRA; SPACE RADIATION; PEAK; SUPRALINEARITY; TL; DEPENDENCE; EFFICIENCY;
D O I
10.1093/rpd/ncp272
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The dose response of LiF:Mg,Ti (TLD-100) chips was measured from 1 to 50 000 Gy using 100 keV X rays at the European Synchroton Radial ion Facility. Glow curves were deconvoluted into component glow peaks using a computerised glow curve deconvolution (CGCD) code based on first-order kinetics. The normalised dose response, f(D), of glow peaks 4 and 5 and 5b (the major components of composite peak 5), as well as peaks 7 and 8 (two of the major components of the high-temperature thermoluminescence (HTTL) at high levels of dose) was separately determined and theoretically interpreted using the unified interaction model (UNIM). The UNIM is a nine-parameter model encompassing both the irradiation/absorption stage and the thermally induced relaxation/recombination stage with an admixture of both localised and delocalised recombination mechanisms. The effects of radiation damage are included in the present modelling via the exponential removal of luminescent centres (LCs) at high dose levels. The main features of the experimentally measured dose response are: (i) increase in f(D)(max) with glow peak temperature, (ii) increase in D-max (the dose level at which f(D)(max) occurs) with increasing glow peak temperature, and (iii) decreased effects of radiation damage with increasing glow peak temperature. The UNIM interpretation of this behaviour requires both strongly decreasing values of ks (the relative contribution of localised recombination) as a function of glow peak temperature and, as well, significantly different values of the dose-filling constants of the trapping centre (TC) and LC for peaks 7 and 8 than those used for peaks 4 and 5. This suggests that different TC/LC configurations are responsible for HTTL. The relative intensity of peak 5a (a low-temperature satellite of peak 5 arising front localised recombination) was found to significantly increase at higher dose levels due to preferential electron and hole population of the trapping/recombination complex giving rise to composite glow peak 5. It is also demonstrated that possible changes in the trapping cross section of the LC and the competitive centres due to increasing sample/glow peak temperature do not significantly influence these observations/conclusions.
引用
收藏
页码:320 / 333
页数:14
相关论文
共 41 条
[1]   The peculiarities of hydroxyl impurity behaviour in crystalline UF and MgO matrices under the action of radiation [J].
Akhvlediani, Z. ;
Kvatchadze, V. .
PHYSICA STATUS SOLIDI C - CURRENT TOPICS IN SOLID STATE PHYSICS, VOL 4, NO 3, 2007, 4 (03) :1163-+
[2]  
BENSHACHAR B, 1988, RADIAT PROT DOSIM, V22, P87
[3]   TL-efficiency - Overview and experimental results over the years [J].
Berger, T. ;
Hajek, M. .
RADIATION MEASUREMENTS, 2008, 43 (2-6) :146-156
[4]   Application of the high-temperature ratio method for evaluation of the depth distribution of dose equivalent in a water-filled phantom on board Space Station Mir [J].
Berger, T ;
Hajek, M ;
Schöner, W ;
Fugger, M ;
Vana, N ;
Akatov, Y ;
Shurshakov, V ;
Arkhangelsky, V ;
Kartashov, D .
RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) :503-506
[5]   Investigation of the emission spectra of LiF:Mg,Ti (TLD-100) during thermoluminescence [J].
Biderman, S ;
Horowitz, Y ;
Oster, L .
RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) :369-372
[6]  
Braunlich P., 1979, TOPICS APPL PHYS THE
[7]  
DATZ H, 2009, 7 INT C LUM DET TRAN
[8]  
FUKS E, 2009, 15 INT S MICR OCT VE
[9]   Thermoluminescent response and relative efficiency of TLD-100 exposed to low-energy x-rays [J].
Gamboa-DeBuen, I ;
Buenfil, AE ;
Ruiz, CG ;
Rodriguez-Villafuerte, M ;
Flores, A ;
Brandan, ME .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08) :2073-2083
[10]   SIMULTANEOUS EVALUATION OF THE NEUTRON AND GAMMA DOSE WITH A SINGLE 6LIF TLD [J].
HORIUCHI, N ;
SATO, T ;
MORIMOTO, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 317 (03) :545-552