Percutaneous Mechanical Assistance for the Failing Heart

被引:27
作者
De Souza, Cristiano Freitas [1 ]
Brito, Flavio De Souza [1 ]
De Lima, Valter Correia [1 ]
De Camargo Carvalho, Antonio Carlos [1 ]
机构
[1] Univ Fed Sao Paulo, Dept Cardiol, BR-04024002 Sao Paulo, Brazil
关键词
LEFT-VENTRICULAR ASSIST; INTRAAORTIC BALLOON PUMP; CARDIOGENIC-SHOCK; DEVICE; SUPPORT; BRIDGE; TANDEMHEART; RECOVERY; SAFETY;
D O I
10.1111/j.1540-8183.2010.00536.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
One of the most challenging situations in contemporary medicine is, doubtlessly, the approach and treatment of patients presenting with severe left ventricle failure. Since its first clinical application in patients with cardiogenic shock in 1968, the intraaortic balloon pump (IABP) has been widely accepted by heart failure physicians. Although IABP therapy has been shown to be effective for the support and stabilization of hemodynamically compromised patients, it has failed to promote any improvements in patient outcomes. For this reason, much attention has been invested in the development of external devices that can collaborate with the treatment of this condition. In this context, the percutaneous left ventricle assist device (pLVAD), like TandemHeart (Cardiac Assist, Inc.; Pittsburgh, PA, USA), and, more recently, the Impella 2.5 (Abiomed Europe, Aachen, Germany) has emerged. The purpose of this review is to describe the history of pLVAD, from its beginning, to the other devices currently available, including those created for right ventricle and biventricular support. (J Interven Cardiol 2010;23:195-202).
引用
收藏
页码:195 / 202
页数:8
相关论文
共 35 条
  • [11] Safety and feasibility of elective high-risk percutaneous coronary intervention procedures with left ventricular support of the Impella Recover LP 2.5
    Henriques, JPS
    Remmelink, M
    Baan, J
    van der Schaaf, RJ
    Vis, MM
    Koch, KT
    Scholten, EW
    de Mol, BAJM
    Tijssen, JGP
    Piek, JJ
    de Winter, RJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (07) : 990 - 992
  • [12] Jiang Chen-yang, 2003, J Zhejiang Univ Sci, V4, P607
  • [13] An evaluation of mapped species distribution models used for conservation planning
    Johnson, CJ
    Gillingham, MP
    [J]. ENVIRONMENTAL CONSERVATION, 2005, 32 (02) : 117 - 128
  • [14] INITIAL CLINICAL EXPERIENCE WITH INTRAAORTIC BALLOON PUMPING IN CARDIOGENIC SHOCK
    KANTROWITZ, A
    TJONNELAND, S
    FREED, PS
    PHILLIPS, SJ
    BUTNER, AN
    SHERMAN, JL
    [J]. JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1968, 203 (02) : 113 - +
  • [15] Kar B, 2004, TEX HEART I J, V31, P84
  • [16] Khalife WI, 2007, TEX HEART I J, V34, P209
  • [17] La Francesca S, 2006, TEX HEART I J, V33, P490
  • [18] Percutaneous left ventricular support devices
    Lee, Michael S.
    Makkar, Raj R.
    [J]. CARDIOLOGY CLINICS, 2006, 24 (02) : 265 - +
  • [19] Usefulness of percutaneous left ventricular assistance to support high-risk percutaneous coronary interventions
    Lemos, PA
    Cummins, P
    Lee, CH
    Degertekin, M
    Gardien, M
    Ottervanger, JP
    Vranckx, P
    de Feyter, P
    Serruys, PW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (04) : 479 - +
  • [20] MacDonald Russell D, 2005, Prehosp Emerg Care, V9, P449, DOI 10.1080/10903120500255917