Segmentation of the carotid intima-media region in B-mode ultrasound images

被引:64
作者
Rocha, Rui [1 ,2 ]
Campilho, Aurelio [1 ,3 ]
Silva, Jorge [1 ,3 ]
Azevedo, Elsa [4 ,5 ]
Santos, Rosa [5 ]
机构
[1] INEB, Div Sinal & Imagem, P-4200465 Oporto, Portugal
[2] ISEP, Dept Matemat, P-420072 Oporto, Portugal
[3] Univ Porto, Fac Engn, P-4200465 Oporto, Portugal
[4] Univ Porto, Fac Med, P-4200319 Oporto, Portugal
[5] Hosp Sao Joao, Dept Neurol, P-4200319 Oporto, Portugal
关键词
Ultrasound image; Carotid; Image segmentation; Dynamic programming; Geometric snakes; Thresholding; ARTERY INTIMA; CLINICAL MEASUREMENT; EDGE-DETECTION; THICKNESS; SYSTEM; SNAKES; RISK; WALL;
D O I
10.1016/j.imavis.2009.09.017
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper proposes a new approach for the segmentation of both near-end and far-end intima-media regions of the common carotid artery in ultrasound images. The method requires minimal user interaction and is able to segment the near-end wall in arteries with large, hypoechogenic and irregular plaques, issues usually not considered previously due to the increased segmentation difficulty. The adventitia is detected by searching for the best fit of a cubic spline to edges having features compatible with the adventitia boundary. The algorithm uses a global smoothness constraint and integrates discriminating features of the adventitia to reduce the attraction by other edges. Afterwards, using the information of the adventitia location, the lumen boundary is detected by combining dynamic programming, smooth intensity thresholding surfaces and geometric snakes. Smooth contours that correctly adapt to the intima are produced, even in the presence of deep concavities. Moreover, unlike balloon-based snakes, the propagation force does not depend on gradients and does not require a predefined direction. An extensive statistical evaluation is computed, using a set of 47 images from 24 different symptomatic patients, including several classes, sizes and shapes of plaques. Bland-Altman plots of the mean intima-media thickness, for manual segmentations of two medical experts, show a high intra-observer and inter-observer agreement, with mean differences close to zero (mean between -0.10 mm and 0.18 mm) and with the large majority of differences within the limits of agreement (standard deviation between 0.10 mm and 0.12 mm). Similar Plots reveal it good agreement between the automatic and the manual segmentations (mean between -0.07 mm and 0.11 mm and standard deviation between 0.11 mm and 0.12 mm). (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:614 / 625
页数:12
相关论文
共 50 条
  • [21] DEEP LEARNING-BASED CAROTID PLAQUE SEGMENTATION FROM B-MODE ULTRASOUND IMAGES
    Zhou, Ran
    Azarpazhooh, M. Reza
    Spence, J. David
    Hashemi, Samineh
    Ma, Wei
    Cheng, Xinyao
    Gan, Haitao
    Ding, Mingyue
    Fenster, Aaron
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (09) : 2723 - 2733
  • [22] Segmentation of intima media complex from carotid ultrasound images using wind driven optimization technique
    Nagaraj, Y.
    Madipalli, Pardhu
    Rajan, Jeny
    Kumar, P. Krishna
    Narasimhadhan, A. V.
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2018, 40 : 462 - 472
  • [23] A method for measuring the variation of intima-media thickness during the entire cardiac cycle using B-Mode images
    Nilsson, Tobias
    Ahlgren, Asa Ryden
    Jansson, Tomas
    Persson, Hans W.
    Lindstrom, Kjell
    Nilsson, Jan
    Cinthio, Magnus
    [J]. 2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 2126 - 2129
  • [24] Ultrasound intima-media segmentation using Hough transform and dual snake model
    Xu, Xiangyang
    Zhou, Yuan
    Cheng, Xinyao
    Song, Enmin
    Li, Guokuan
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2012, 36 (03) : 248 - 258
  • [25] Carotid Intima-Media Thickness after Pediatric Renal or Liver Transplantation at High-Resolution B-Mode Ultrasonography
    Siirtola, A.
    Kallio, T.
    Ala-Houhala, M.
    Lehtimaki, T.
    Solakivi, T.
    Antikainen, M.
    Salo, M. K.
    Holmberg, C.
    [J]. TRANSPLANTATION PROCEEDINGS, 2010, 42 (05) : 1695 - 1698
  • [26] Evaluation of a new carotid intima-media thickness measurement by B-mode ultrasonography using an innovative measurement software, intimascope
    Yanase, Toshihiko
    Nasu, Shigeru
    Mukuta, Yoshihiro
    Shimizu, Yutaka
    Nishihara, Tetsu
    Okabe, Taijiro
    Nomura, Masatoshi
    Inoguchi, Toyoshi
    Nawata, Hajime
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2006, 19 (12) : 1206 - 1212
  • [27] Carotid plaque and intima-media thickness assessed by B-mode ultrasonography in subjects ranging from young adults to centenarians
    Homma, S
    Hirose, N
    Ishida, H
    Ishii, T
    Araki, G
    [J]. STROKE, 2001, 32 (04) : 830 - 834
  • [28] Evaluation of carotid intima media thickness measurement from ultrasound images
    Smitha, B.
    Yadav, Dhanraj
    Joseph, Paul K.
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2022, 60 (02) : 407 - 419
  • [29] Automatic detection of the intima-media thickness in ultrasound images of the common carotid artery using neural networks
    Menchon-Lara, Rosa-Maria
    Bastida-Jumilla, Maria-Consuelo
    Morales-Sanchez, Juan
    Sancho-Gomez, Jose-Luis
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2014, 52 (02) : 169 - 181
  • [30] Detection of Intima-media Thickness in Common Carotid Artery on Ultrasound Image
    He, Xing-wu
    [J]. INFORMATION ENGINEERING FOR MECHANICS AND MATERIALS RESEARCH, 2013, 422 : 165 - 171