Segmentation of the carotid intima-media region in B-mode ultrasound images

被引:64
|
作者
Rocha, Rui [1 ,2 ]
Campilho, Aurelio [1 ,3 ]
Silva, Jorge [1 ,3 ]
Azevedo, Elsa [4 ,5 ]
Santos, Rosa [5 ]
机构
[1] INEB, Div Sinal & Imagem, P-4200465 Oporto, Portugal
[2] ISEP, Dept Matemat, P-420072 Oporto, Portugal
[3] Univ Porto, Fac Engn, P-4200465 Oporto, Portugal
[4] Univ Porto, Fac Med, P-4200319 Oporto, Portugal
[5] Hosp Sao Joao, Dept Neurol, P-4200319 Oporto, Portugal
关键词
Ultrasound image; Carotid; Image segmentation; Dynamic programming; Geometric snakes; Thresholding; ARTERY INTIMA; CLINICAL MEASUREMENT; EDGE-DETECTION; THICKNESS; SYSTEM; SNAKES; RISK; WALL;
D O I
10.1016/j.imavis.2009.09.017
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
This paper proposes a new approach for the segmentation of both near-end and far-end intima-media regions of the common carotid artery in ultrasound images. The method requires minimal user interaction and is able to segment the near-end wall in arteries with large, hypoechogenic and irregular plaques, issues usually not considered previously due to the increased segmentation difficulty. The adventitia is detected by searching for the best fit of a cubic spline to edges having features compatible with the adventitia boundary. The algorithm uses a global smoothness constraint and integrates discriminating features of the adventitia to reduce the attraction by other edges. Afterwards, using the information of the adventitia location, the lumen boundary is detected by combining dynamic programming, smooth intensity thresholding surfaces and geometric snakes. Smooth contours that correctly adapt to the intima are produced, even in the presence of deep concavities. Moreover, unlike balloon-based snakes, the propagation force does not depend on gradients and does not require a predefined direction. An extensive statistical evaluation is computed, using a set of 47 images from 24 different symptomatic patients, including several classes, sizes and shapes of plaques. Bland-Altman plots of the mean intima-media thickness, for manual segmentations of two medical experts, show a high intra-observer and inter-observer agreement, with mean differences close to zero (mean between -0.10 mm and 0.18 mm) and with the large majority of differences within the limits of agreement (standard deviation between 0.10 mm and 0.12 mm). Similar Plots reveal it good agreement between the automatic and the manual segmentations (mean between -0.07 mm and 0.11 mm and standard deviation between 0.11 mm and 0.12 mm). (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:614 / 625
页数:12
相关论文
共 50 条
  • [1] Detections of Intima-Media Thickness in B-Mode Carotid Artery Images Using Segmentation Methods
    Savithri, V.
    Purushothaman, S.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON INTERNET COMPUTING AND INFORMATION COMMUNICATIONS (ICICIC GLOBAL 2012), 2014, 216 : 471 - 482
  • [2] B-mode carotid ultrasound can go beyond intima-media thickness
    Perez-Moreno, A.
    Gilabert, R.
    Ros, E.
    Amat-Roldan, I.
    CARDIOVASCULAR RESEARCH, 2012, 93 : S87 - S87
  • [3] Automatic intima-media thickness measurement of carotid artery wall in B-mode sonographic images
    Cheng, Da-Chuan
    Jiang, Xiaoyi
    Schmidt-Trucksaess, Amo
    Cheng, Kuo-Sheng
    2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 912 - +
  • [4] Carotid Artery Segmentation in Ultrasound Images and Measurement of Intima-Media Thickness
    Naik, Vaishali
    Gamad, R. S.
    Bansod, P. P.
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [5] Anisotropic edge-preserving smoothing in carotid B-mode ultrasound for improved segmentation and intima-media thickness (IMT) measurement
    Chan, RC
    Kaufhold, J
    Hemphill, LC
    Lees, RS
    Karl, WC
    COMPUTERS IN CARDIOLOGY 2000, VOL 27, 2000, 27 : 37 - 40
  • [6] Carotid wall stress calculated with continuous intima-media thickness assessment using B-mode ultrasound
    Pascaner, A. F.
    Craiem, D.
    Casciaro, M. E.
    Danielo, R.
    Graf, S.
    Guevara, E.
    20TH ARGENTINEAN BIOENGINEERING SOCIETY CONGRESS (XX ARGENTINE BIOENGINEERING CONGRESS AND IX CONFERENCE OF CLINICAL ENGINEERING), (SABI 2015), 2016, 705
  • [7] INTELLIGENT SEGMENTATION OF INTIMA-MEDIA AND PLAQUE RECOGNITION IN CAROTID ARTERY ULTRASOUND IMAGES
    Lin, Yanping
    Huang, Jianhua
    Chen, Yuhang
    Chen, Qingqing
    Li, Zhaojun
    Cao, Qixin
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (03): : 469 - 479
  • [8] Individual measurement and significance of carotid intima, media, and intima-media thickness by B-mode ultrasonographic image processing
    Bae, Jang-Ho
    Kim, Wuon-Shik
    Rihal, Charanjit S.
    Lerman, Amir
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2006, 26 (10) : 2380 - 2385
  • [9] EVALUATION OF COMPUTERIZED EDGE TRACKING FOR QUANTIFYING INTIMA-MEDIA THICKNESS OF THE COMMON CAROTID-ARTERY FROM B-MODE ULTRASOUND IMAGES
    SELZER, RH
    HODIS, HN
    KWONGFU, H
    MACK, WJ
    LEE, PL
    LIU, CR
    LIU, CH
    ATHEROSCLEROSIS, 1994, 111 (01) : 1 - 11
  • [10] Carotid and femoral B-mode ultrasound intima-media thickness measurements in adult post-coarctectomy patients
    Vriend, JJW
    de Groot, E
    Kastelein, JJP
    Mulder, BJM
    INTERNATIONAL ANGIOLOGY, 2004, 23 (01) : 41 - 46