Device for Catheter Placement of External Ventricular Drain

被引:7
作者
Ann, Jae-Min [1 ]
Bae, Hack-Gun [1 ]
Oh, Jae-Sang [1 ]
Yoon, Seok-Mann [1 ]
机构
[1] Soonchunhyang Univ, Cheonan Hosp, Dept Neurosurg, Sch Med, Cheonan, South Korea
关键词
External ventricular drain; Device; Cerebrospinal fluid; ACCURACY;
D O I
10.3340/jkns.2016.59.3.322
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
To introduce a new device for catheter placement of an external ventricular drain (EVD) of cerebrospinal fluid (CSF). This device was composed of three portions, T-shaped main body, rectangular pillar having a central hole to insert a catheter and an arm pointing the tragus. The main body has a role to direct a ventricular catheter toward the right or left inner canthus and has a shallow longitudinal opening to connect the rectangular pillar. The arm pointing the tragus is controlled by back and forth movement and turn of the pillar attached to the main body. Between April 2012 and December 2014, 57 emergency EVDs were performed in 52 patients using this device in the operating room. Catheter tip located in the frontal horn in 52 (91.2%), 3rd ventricle in 2 (3.5%) and in the wall of the frontal horn of the lateral ventricle in 3 EVDs (5.2%). Small hemorrhage along to catheter tract occurred in 1 EVD. CSF was well drained through the all EVD catheters. The accuracy of the catheter position and direction using this device were 91% and 100%, respectively. This device for EVD guides to provide an accurate position of catheter tip safely and easily.
引用
收藏
页码:322 / 324
页数:3
相关论文
共 7 条
  • [1] CONTROL OF HYDROCEPHALUS BY VALVE-REGULATED VENOUS SHUNT - AVOIDANCE OF COMPLICATIONS IN PROLONGED SHUNT MAINTENANCE
    BECKER, DP
    NULSEN, FE
    [J]. JOURNAL OF NEUROSURGERY, 1968, 28 (03) : 215 - &
  • [2] A GUIDE FOR VENTRICULAR CATHETER PLACEMENT
    GHAJAR, JBG
    [J]. JOURNAL OF NEUROSURGERY, 1985, 63 (06) : 985 - 986
  • [3] Hsieh CT, 2011, ACTA NEUROL BELG, V111, P22
  • [4] Accuracy of the freehand pass technique for ventriculostomy catheter placement: retrospective assessment using computed tomography scans
    Huyette, David R.
    Turnbow, Benjamin J.
    Kaufman, Christian
    Vaslow, Dale F.
    Whiting, Benjamin B.
    Oh, Michael Y.
    [J]. JOURNAL OF NEUROSURGERY, 2008, 108 (01) : 88 - 91
  • [5] LEE JH, 2010, KOREAN J CEREBROVASC, V12, P82
  • [6] A survey of ventriculostomy and intracranial. pressure monitor placement practices
    O'Neill, Brent R.
    Velez, Dennis A.
    Braxton, Ernest E.
    Whiting, Donald
    Oh, Michael Y.
    [J]. SURGICAL NEUROLOGY, 2008, 70 (03): : 268 - 273
  • [7] EXTERNAL VENTRICULAR DRAIN INSERTION ACCURACY: IS THERE A NEED FOR CHANGE IN PRACTICE?
    Toma, Ahmed K.
    Camp, Sophie
    Watkins, Laurence D.
    Grieve, Joan
    Kitchen, Neil D.
    [J]. NEUROSURGERY, 2009, 65 (06) : 1197 - 1200